Comparative performance of multi-view stereoscopic and mammographic display modalities for breast lesion detection

DukeSpace

Show simple item record

dc.contributor.advisor Samei, Ehsan en_US
dc.contributor.author Webb, Lincoln Jon en_US
dc.date.accessioned 2010-05-13T17:54:04Z
dc.date.available 2011-07-26T04:30:04Z
dc.date.issued 2010 en_US
dc.identifier.uri http://hdl.handle.net/10161/2508
dc.description Thesis en_US
dc.description.abstract <p><bold>Rationale and Objectives:</bold> Mammography is known to be one of the most difficult radiographic exams to interpret. Mammography has important limitations including superposition of normal tissue that can obscure a mass, chance alignment of normal tissue to mimic a true lesion, and the inability to derive volumetric information. It has been shown that stereomammography can overcome these deficiencies by showing that layers of normal tissue lay at different depths. If standard stereomammography (i.e. a single stereoscopic pair consisting of 2 projection images) can significantly improve lesion detection, how will multi-view stereoscopy (MVS), where many projection images are used, compare to mammography? The aim of this study was to assess the relative performance of MVS compared to mammography for breast mass detection.</p> <p><bold>Materials and Methods:</bold> The MVS image sets consisted of the 25 raw projection images acquired over an arc of approximately 45&deg; using a Siemens prototype breast tomosynthesis system. The mammograms were acquired using a commercial Siemens FFDM system. The raw data was taken from both of these systems for 27 cases and realistic simulated mass lesions were added to duplicates of the 27 images at the same local contrast. The images with lesions (27 mammography and 27 MVS) and the images without lesions (27 mammography and 27 MVS) were then post-processed to provide comparable and representative image appearance across the two modalities. All 108 image sets were shown to five full-time breast imaging radiologists in random order on a state-of-the-art stereoscopic display. The observers were asked to give a confidence rating for each image (0 for lesion definitely not present, 100 for lesion definitely present). The ratings were then compiled and processed using ROC and variance analysis. </p> <p><bold>Results:</bold> The mean AUC for the five observers was 0.614&plusmn;0.055 for mammography and 0.778&plusmn;0.052 for multi-view stereoscopy. The difference of 0.164&plusmn;0.065 was statistically significant with a p-value of 0.0148.</p> <p><bold>Conclusion:</bold> The differences in the AUCs and the p-value suggest that multi-view stereoscopy has a statistically significant advantage over mammography in the detection of simulated breast masses. This highlights the dominance of anatomical noise compared to quantum noise for breast mass detection. It also shows that significant lesion detection can be achieved with MVS without any of the artifacts associated with tomosynthesis.</p> en_US
dc.format.extent 4541524 bytes
dc.format.mimetype application/pdf
dc.language.iso en_US
dc.subject Health Sciences, Radiology en_US
dc.subject Physics, Radiation en_US
dc.subject Biophysics, Medical en_US
dc.subject Breast-Cancer en_US
dc.subject lesion detection en_US
dc.subject mammography en_US
dc.subject multi-view stereoscopy en_US
dc.subject observer performance en_US
dc.subject ROC en_US
dc.title Comparative performance of multi-view stereoscopic and mammographic display modalities for breast lesion detection en_US
dc.type Thesis en_US
dc.department Medical Physics en_US