DukeSpace will be down for maintenance at 9:15 AM EDT on Tuesday, July 29. Expected downtime is 20 minutes or less.

Show simple item record

dc.contributor.advisor Johnson, G. A. en_US
dc.contributor.author Lin, Ming De en_US
dc.date.accessioned 2008-09-03T14:11:00Z
dc.date.available 2008-09-03T14:11:00Z
dc.date.issued 2008-08-04 en_US
dc.identifier.uri http://hdl.handle.net/10161/831
dc.description Dissertation en_US
dc.description.abstract <p>Research using mice and rats has gained interest because they are robust test beds for clinical drug development and are used to elucidate disease etiologies. Blood vessel visualization and blood flow measurements are important anatomic and physiologic indicators to drug/disease stimuli or genetic modification. Cardio-pulmonary blood flow is an important indicator of heart and lung performance. Small animal functional imaging provides a way to measure physiologic changes minimally-invasively while the animal is alive, thereby allowing for multiple measurements in the same animal with little physiologic perturbation. Current methods of measuring cardio-pulmonary blood flow suffer from some or all of these limitations-they produce relative measurements, are limited to global or whole animal or organ regions, do not provide vasculature visualization, limited to a few or singular samples per animal, are not able to measure acute changes, or are very invasive or requires animal sacrifice. The focus of this work was the development of a small animal x-ray imaging system capable of minimally invasive real-time, high resolution vascular visualization, and cardio-pulmonary blood flow measurements in the live animal. The x-ray technique used was digital subtraction angiography (DSA). This technique is a particularly appealing approach because it is easy to use, can capture rapid physiological changes on a heart beat-to-beat basis, and provides anatomical and functional vasculature information. This DSA system is special because it was designed and implemented from the ground up to be optimized for small animal imaging and functional measurements. This system can perform: 1) minimally invasive in vivo blood flow measurements, 2) multiple measurements in the same animal in a rapid succession (every 30 seconds-a substantial improvement over singular measurements that require minutes to acquire by the Fick method), 3) very high resolution (up to 46 micron) vascular visualization, 4) quantitative blood flow measurements in absolute metrics (mL/min instead of arbitrary units or velocity) and relative blood volume dynamics from discrete ROIs, and 5) relative mean transit time dynamics on a pixel-by-pixel basis (100 µm x 100 µm). The end results are 1) anatomical vessel time course images showing the contrast agent flowing through the vasculature, 2) blood flow information of the live rat cardio-pulmonary system in absolute units and relative blood volume information at discrete ROIs of enhanced blood vessels, and 3) colormaps of relative transit time dynamics. This small animal optimized imaging system can be a useful tool in future studies to measure drug or disease modulated blood flow dynamics in the small animal.</p> en_US
dc.format.extent 14731776 bytes
dc.format.mimetype application/pdf
dc.language.iso en_US
dc.subject Engineering, Biomedical en_US
dc.subject Physics, Radiation en_US
dc.subject Biology, Physiology en_US
dc.subject X-ray Imaging en_US
dc.subject Digital Subtraction Angiography en_US
dc.subject Rodent en_US
dc.subject Blood Flow en_US
dc.subject Cardio-pulmonary en_US
dc.subject Imaging en_US
dc.title High Resolution X-ray Microscopy Using Digital Subtraction Angiography for Small Animal Functional Imaging en_US
dc.type Dissertation en_US
dc.department Biomedical Engineering en_US
duke.embargo.months 12 en_US
dc.date.accessible 2009-08-04T05:00:02Z

Files in this item

This item appears in the following Collection(s)

Show simple item record