Browsing by Author "Breitenbeck, Nancy"
Now showing 1 - 2 of 2
Results Per Page
Sort Options
Item Open Access Analytical performance evaluation of the Elecsys® Troponin T Gen 5 STAT assay.(Clinica chimica acta; international journal of clinical chemistry, 2019-08) Fitzgerald, Robert L; Hollander, Judd E; Peacock, W Frank; Limkakeng, Alexander T; Breitenbeck, Nancy; Blechschmidt, Kareen; Laimighofer, Michael; deFilippi, ChristopherBACKGROUND:We report the analytical performance of the Elecsys® Troponin T Gen 5 STAT (TnT Gen 5 STAT; Roche Diagnostics) assay. METHODS:Measuring limits/ranges were determined in lithium-heparin plasma samples per Clinical and Laboratory Standards Institute (CLSI) EP17-A2. Precision was evaluated per CLSI EP05-A2 using lithium-heparin plasma/quality control samples on cobas e 411/cobas e 601 analyzers; two duplicated runs per day for 21 days (n = 84). Cross-reactivity with other troponin forms and interference from endogenous substances/drugs was tested; recovery criterion for no cross-reactivity was within ±10%. RESULTS:Coefficients of variation (CV) for repeatability/intermediate precision were 0.7-5.6%/1.4-10.3% (cobas e 411; mean cardiac troponin T [cTnT]: 7.3-9341 ng/L) and 0.7-3.0%/1.5-6.4% (cobas e 601; mean cTnT: 7.4-9455 ng/L). There was no cross-reactivity with skeletal muscle troponin T (≤ 10,000 ng/L), skeletal muscle troponin I (≤ 100,000 ng/L), cardiac troponin I (≤ 10,000 ng/L), or human troponin C (≤ 80,000 ng/L). No interference was observed with biotin (≤ 20 ng/mL) or 34 drugs. CONCLUSION:The TnT Gen 5 STAT assay demonstrated a CV of <10% at the 99th percentile upper reference limit, meeting precision requirements (Fourth Universal Definition of Myocardial Infarction) for high-sensitivity troponin assays.Item Open Access The 99th percentile upper reference limit for the 5th generation cardiac troponin T assay in the United States.(Clinica chimica acta; international journal of clinical chemistry, 2020-05) Fitzgerald, Robert L; Hollander, Judd E; Peacock, W Frank; Limkakeng, Alexander T; Breitenbeck, Nancy; Rivers, E Joy; Ziegler, André; Laimighofer, Michael; deFilippi, ChristopherBACKGROUND:Determining diagnostic thresholds for cardiac troponin assays is key to interpreting their clinical performance. We describe the calculation of 99th percentile upper reference limits (URLs) for the Elecsys® Troponin T Gen 5 (TnT Gen 5) assay. METHODS:Plasma and serum samples from healthy US participants were prospectively evaluated using TnT Gen 5 Short Turn Around Time and 18-min assays on cobas e 411 and cobas e 601 analyzers (Roche Diagnostics); with, up to 8 TnT Gen 5 results per participant. RESULTS:A total of 10,402 TnT Gen 5 results from 1301 participants were included (50.4% female). Across 9 calculation methods, overall 99th percentile URL was 19.2 ng/l (females, 13.5-13.6 ng/l; males, 21.4-22.2 ng/l). Across different sample/assay/analyzer combinations, overall 99th percentile URLs ranged from 18.4-20.2 ng/l. Median TnT Gen 5 results increased with age, were higher in males, and ranged from 3.0-3.7 ng/l across races/ethnicities and from 3.0-3.6 ng/l across body mass index (BMI) classes. Applying additional exclusion criteria (N-terminal pro-brain natriuretic peptide, BMI and estimated glomerular filtration rate) resulted in lower 99th percentile URLs (overall, 16.9 ng/l; females, 11.8 ng/l; males, 18.5 ng/l). CONCLUSION:Our findings facilitate the interpretation of TnT Gen 5 results in US clinical practice.