Browsing by Author "Das, Shiva"
Now showing 1 - 3 of 3
- Results Per Page
- Sort Options
Item Open Access Assessing cardiac injury in mice with dual energy-microCT, 4D-microCT, and microSPECT imaging after partial heart irradiation.(Int J Radiat Oncol Biol Phys, 2014-03-01) Lee, Chang-Lung; Min, Hooney; Befera, Nicholas; Clark, Darin; Qi, Yi; Das, Shiva; Johnson, G Allan; Badea, Cristian T; Kirsch, David GPURPOSE: To develop a mouse model of cardiac injury after partial heart irradiation (PHI) and to test whether dual energy (DE)-microCT and 4-dimensional (4D)-microCT can be used to assess cardiac injury after PHI to complement myocardial perfusion imaging using micro-single photon emission computed tomography (SPECT). METHODS AND MATERIALS: To study cardiac injury from tangent field irradiation in mice, we used a small-field biological irradiator to deliver a single dose of 12 Gy x-rays to approximately one-third of the left ventricle (LV) of Tie2Cre; p53(FL/+) and Tie2Cre; p53(FL/-) mice, where 1 or both alleles of p53 are deleted in endothelial cells. Four and 8 weeks after irradiation, mice were injected with gold and iodinated nanoparticle-based contrast agents, and imaged with DE-microCT and 4D-microCT to evaluate myocardial vascular permeability and cardiac function, respectively. Additionally, the same mice were imaged with microSPECT to assess myocardial perfusion. RESULTS: After PHI with tangent fields, DE-microCT scans showed a time-dependent increase in accumulation of gold nanoparticles (AuNp) in the myocardium of Tie2Cre; p53(FL/-) mice. In Tie2Cre; p53(FL/-) mice, extravasation of AuNp was observed within the irradiated LV, whereas in the myocardium of Tie2Cre; p53(FL/+) mice, AuNp were restricted to blood vessels. In addition, data from DE-microCT and microSPECT showed a linear correlation (R(2) = 0.97) between the fraction of the LV that accumulated AuNp and the fraction of LV with a perfusion defect. Furthermore, 4D-microCT scans demonstrated that PHI caused a markedly decreased ejection fraction, and higher end-diastolic and end-systolic volumes, to develop in Tie2Cre; p53(FL/-) mice, which were associated with compensatory cardiac hypertrophy of the heart that was not irradiated. CONCLUSIONS: Our results show that DE-microCT and 4D-microCT with nanoparticle-based contrast agents are novel imaging approaches complementary to microSPECT for noninvasive assessment of the change in myocardial vascular permeability and cardiac function of mice in whom myocardial injury develops after PHI.Item Open Access Early 18F-FDG-PET Response During Radiation Therapy for HPV-Related Oropharyngeal Cancer May Predict Disease Recurrence.(International journal of radiation oncology, biology, physics, 2020-11) Mowery, Yvonne M; Vergalasova, Irina; Rushing, Christel N; Choudhury, Kingshuk Roy; Niedzwiecki, Donna; Wu, Qiuwen; Yoo, David S; Das, Shiva; Wong, Terence Z; Brizel, David MPurpose
Early indication of treatment outcome may guide therapeutic de-escalation strategies in patients with human papillomavirus (HPV)-related oropharyngeal cancer (OPC). This study investigated the relationships between tumor volume and 18F-fluorodeoxyglucose positron emission tomography (PET) parameters before and during definitive radiation therapy with treatment outcomes.Methods and materials
Patients undergoing definitive (chemo)radiation for HPV-related/p16-positive OPC were prospectively enrolled on an institutional review board-approved study. 18F-fluorodeoxyglucose PET/computed tomography scans were performed at simulation and after 2 weeks at a dose of ∼20 Gy. Tumor volume and standardized uptake value (SUV) characteristics were measured. SUV was normalized to blood pool uptake. Tumor volume and PET parameters associated with recurrence were identified through recursive partitioning (RPART). Recurrence-free survival (RFS) and overall survival (OS) curves between RPART-identified cohorts were estimated using the Kaplan-Meier method, and Cox models were used to estimate the hazard ratios (HRs).Results
From 2012 to 2016, 62 patients with HPV-related OPC were enrolled. Median follow-up was 4.4 years. RPART identified patients with intratreatment SUVmax (normalized to blood pool SUVmean) <6.7 or SUVmax (normalized to blood pool SUVmean) ≥6.7 with intratreatment SUV40% ≥2.75 as less likely to recur. For identified subgroups, results of Cox models showed unadjusted HRs for RFS and OS (more likely to recur vs less likely) of 7.33 (90% confidence interval [CI], 2.97-18.12) and 6.09 (90% CI, 2.22-16.71), respectively, and adjusted HRs of 6.57 (90% CI, 2.53-17.05) and 5.61 (90% CI, 1.90-16.54) for RFS and OS, respectively.Conclusions
PET parameters after 2 weeks of definitive radiation therapy for HPV-related OPC are associated with RFS and OS, thus potentially informing an adaptive treatment approach.Item Open Access Noninvasive measurement of tissue blood oxygenation with Cerenkov imaging during therapeutic radiation delivery(Optics Letters, 2017-08-15) Zhang, Xiaofeng; Lam, Sai Kit; Palmer, Gregory; Das, Shiva; Oldham, Mark; Dewhirst, Mark© 2017 Optical Society of America. Tumor tissue oxygenation significantly affects the outcome of radiotherapy. Real-time monitoring of tumor hypoxia is highly desirable for effective radiotherapy, and is the basis for improved treatment because hypoxic tumor cells are more resistant to radiation damage than fully oxygenated cells. We propose to use Cerenkov imaging to monitor tumor hypoxia by means of tissue blood oxygenation without the need for any exogenous contrast agent. Using a rodent hypoxia model, we demonstrate that Cerenkov imaging can be used as a noninvasive and noncontact method to measure tissue blood oxygenation level during radiation delivery. The data from Cerenkov imaging were validated using near infrared spectrometry methods. The results demonstrate the feasibility of using Cerenkov imaging to monitor tumor hypoxia during therapeutic radiation delivery.