Item Open Access Neutron Dosimetry of Mice Using Monoenergetic Neutron Beams(2011) Fallin, Brent AlanIn 2009 the researchers at Triangle Universities Nuclear Laboratory (TUNL) participated in a series of experiments with the Radiation Countermeasures Center of Research Excellence (RadCCORE). This thesis project is a component of the research done at TUNL that was partially supported by the RadCCORE collaboration. The primary goals of this work are: (1) to measure the neutron fluence (and hence the dose) from the standard neutron beam source at TUNL delivered to a small animal target to an accuracy of better than ± 10% and (2) to develop techniques for real time monitoring of the absolute dose delivered to small animal targets from neutron beam irradiation. These two projects are interconnected as the development of the real-time monitoring techniques depends on the results of the absolute fluence measurements.
Measuring the absolute neutron beam fluence necessitates the use of a reaction in which the neutron cross section is accurately known over the relevant energy range and a detection technique which is insensitive to gamma-rays or is capable of distinguishing gamma-rays from neutrons. In this work, neutron activation of aluminum and gold foils was used to make absolute measurements of the fast neutron (En ~ 10 MeV) fluence. Neutron activation of gold foils was also used to make a relative measurement of the thermal neutron fluence. The neutrons produced nuclear reactions in the foils, converting a small quantity of the stable atoms in the foils into radioactive ones which subsequently generate gamma-rays in their decay process. The activated foils are then removed from the beam and placed in front of a high-purity germanium (HPGe) detector that measures the energy spectrum of the gamma-rays emitted by the foil. By counting the number of gamma-rays detected over a set time, the incident neutron fluence at the foil location was determined using the known reaction cross sections. The measured neutron fluence was used to calculate the imparted dose to live mouse targets via the muscle tissue neutron kerma factors. Liquid and plastic scintillation detectors were also used to monitor the relative neutron flux in real time during the experiments. These relative detectors were subsequently calibrated using flux results obtained from the foil activation measurements and were used for real time dose monitoring.
The neutron beam produced at TUNL also has an intrinsic gamma component that adds to the dose received by a small animal target. The gamma contribution to imparted dose is generally taken to be around 10% or less for neutron beams created by linear accelerators utilizing the 2H(d,n)3He reaction, but no confirming measurements of this type have been performed at TUNL prior to this work. To verify this claim, an experiment was conducted to quantify the gamma-ray contribution to the target dose at several incident neutron energies and gas cell pressures.
The dosage from the mixed beam was measured using two ionization chambers that have different sensitivities to neutron and gamma radiation. The chambers were placed in the neutron beam, and the total charge induced in the ionization chamber by the mixed radiation field was monitored. The percent gamma-ray contribution to total target dose was calculated utilizing the procedures outlined in AAPM Report No. 7 and Attix.
Using the foil activation technique, the neutron fluence incident on target and dose delivered were measured to within ± 10%. The target dose estimated using the scintillation detectors was found to be accurate to within ± 20%. The results of the ion chamber measurements imply the gamma-ray component of the neutron beam at TUNL contributes less than 5% to the total target dose. Given the large difference in quality factors between gamma-rays (=1) and fast neutrons (~10), the contribution by gamma radiation to the total equivalent dose was determined to be negligible.
Item Open Access Nuclear Resonance Fluorescence: Studies on 240Pu for Nuclear Security and Light Nuclei for Medical Diagnostics Applications(2018) Fallin, Brent AlanNuclear resonance fluorescence (NRF) is a highly sensitive technique for measuring the energies and strengths of dipole excitations in nuclei. For incident photon energies below the particle separation threshold, excited nuclear states decay solely through gamma-ray emission, providing a unique de-excitation energy spectrum corresponding to the differences in energy between excited and final states. When excitation cross sections and transition energies are known, the presence (or absence) of a particular isotope within a sample can be determined and quantified. This dissertation describes the use of the NRF technique in two separate areas of active research: nuclear security and medical diagnostics.
In recent years, the nuclear security community has been seeking to develop new photon-beam based technologies for screening cargo for contraband and special nuclear materials (SNM), especially weapons grade material. However, because the current knowledge of dipole excitations in the actinides is highly limited, much greater study of the energy and strengths of dipole excitations in these isotopes is required, with particular focus on isotopes of uranium and plutonium. Nuclear resonance fluorescence studies using mono-energetic gamma-ray beams have previously been conducted at the High Intensity Gamma-Ray Source (HIS) facility at Triangle Universities Nuclear Laboratory (TUNL) on 235U [Kwa11], 238U [Ham12], and 232Th [Ade11]. Additionally, bremsstrahlung surveys below 3 MeV have been conducted at the Massachusetts Institute of Technology’s High Voltage Research Laboratory, examining dipole excited states in 239Pu [Joh07, Ber08] and 240Pu [Qui12].
The first portion of this dissertation provides details of our high-sensitivity measurements of the distribution of dipole excited states observed in 240Pu between 2–3 MeV using the linearly-polarized, quasi-monoenergetic photon beam at the HIS. Measurements were taken at eleven mean beam energies ranging from 1.95 to 2.95 MeV (in 100-keV steps). The target material was powdered plutonium oxide containing 4.65(8) g of 240Pu. Gamma rays corresponding to transitions between excited states in 240Pu were observed using high-purity germanium (HPGe) detectors. The narrow energy resolution of the HIS beam (e.g., E/E ~4% FWHM achieved using a 0.75" lead collimator) greatly reduced background from Compton scattering off the high-Z target material compared to bremsstrahlung measurements, improving the signal-to-noise ratio (SNR) of observed transitions and allowing the observation of low-intensity transitions that would otherwise be below detection threshold. The linear polarization of the HIS beam also allowed the determination of the parity of excited states based on differences in the polar and azimuthal angular distribution of the gamma rays emitted by the target. For each observed transition, the transition energy, partial integrated cross section, partial level width, and reduced transition probability for de-excitation were determined. The excitation energy, spin, parity, total integrated cross section, total level width, reduced transition probability for excitation, and ratio of the reduced transition probabilities (Rexp) were determined for each excited state. A total of 27 discrete transitions were observed from 14 excited states, of which 10 transitions were observed for the first time in the present experiments. Cross sections measured for ground-state decay were higher on average than those previously measured by Quiter et al., while those for 1st excited state decays were largely consistent with the prior measurements. All ground-state transitions were determined to be M1 in character.
The second portion of this dissertation involves measurements made to determine the feasibility of applying the NRF technique to medical diagnostics. Nuclear resonance fluorescence is a potentially valuable new tool for aiding in the diagnosis of medical conditions which cause the natural abundances of elements in the body to be altered. Evidence has been found for statistically significant asymmetries in certain trace element concentrations between healthy (benign) and malignant (cancerous) breast tissue. One of the elements for which a strong (> factor 2) asymmetry has been found is calcium [Riz84, Ng97, Raj06, Sil12]. A likely source of this asymmetry is differences in the calcium concentrations between the two principle forms of calcium containing minerals that comprise breast calcifications, calcium oxalate and calcium phosphate [Hak02]. Calcium oxalate (Type 1) calcifications generally occur in the form of calcium oxalate dihydrate (CaC2O4•2(H2O)) (also called Weddellite) and have been found to always be associated with benign breast tissue. Calcium phosphate (Type 2) calcifications in breast tissue are primarily composed of hydroxylapatite (Ca5(PO4)3(OH)) and are highly associated with malignancy [Win93, Sco17]. While the density of hydroxyapatite containing lesions is typically greater than calcium oxalate, it is not always possible to distinguish them with traditional mammography. A secondary procedure that could determine the isotopic composition of a calcification would be of benefit in reducing the number of biopsies to which patients are subjected.
The experiment was designed to test the feasibility of using the NRF technique to distinguish between calcium oxalate and hydroxylapatite through examination of known strong dipole transitions in calcium and phosphorus. The first part of the experiment involved benchmark measurements of the cross sections of the strongest recorded NRF transitions from excited states in 40Ca (Ex = 10318.8(4) keV) and 31P (Ex = 7141.1(18) keV) using bulk samples of calcium oxide and red phosphorus, respectively. Cross sections for non-ground state transitions from these excited states as well as transitions from additional excited states populated during the experiment were also measured. The cross sections measured for ground-state transitions from the principally targeted states in calcium and phosphorus were consistent with previously published values, and the uncertainty in these cross sections was decreased. Other transition cross sections measured were mostly in agreement with the published values.
For the second part of the experiment, three cylindrical PRESAGE® radiochromic dosimeters, containing either calcium oxide or calcium hydroxylapatite targets were irradiated with the photon beam at the HIS targeting the same transitions in calcium and phosphorus as during the bulk measurements. The goal of these measurements was to determine the ability to distinguish between calcium oxalate and hydroxylapatite calcifications contained in a tissue-simulating medium as well as to determine the corresponding detection limits for calcium and phosphorus. PRESAGE® material was chosen due to its ability to provide 3D depth-dose information as well as effectively mimicking the photon scattering properties of human tissue. The dosimeters were irradiated for sufficient time so as obtain a dose of several grays (Gy) or higher in regions of interest in order to provide a strong signal for post-irradiation optical scanning. Experimentally measured depth-dose curves were then compared to simulated values. The two calcium compounds contained in the PRESAGE® material were able to be clearly distinguished via the strong counting asymmetry observed. The best detection limit for calcium achieved was 99.0(15)(49) mg/cm2 using a single HPGe detector and 73.5(8)(36) mg/cm2 for two HPGe detectors. Likewise, a minimum detection limit (MDL) for phosphorus of 45.6(5)(20) mg/cm2 was achieved using a single HPGe detector and 34.8(3)(15) mg/cm2 for two HPGe detectors. These MDLs were determined to be sufficient for detection of 1 mm hydroxylapatite calcifications in tissue by both calcium and phosphorus detection. The corresponding doses to tissue for photon beams that will likely be available in the near future (e.g., 0.1% FWHM energy resolution) are too high for consideration of NRF-based breast screening in the near term. Minimum detection limits will have to be lowered further and detector system efficiencies increased substantially before in vivo diagnostics becomes viable.