Browsing by Author "Lebel, DE"
Now showing 1 - 2 of 2
Results Per Page
Sort Options
Item Open Access A comparison of three-and two-rod constructs in the correction of severe pediatric scoliosis(Journal of Children's Orthopaedics, 2023-04-01) Machida, M; Rocos, B; Zeller, R; Lebel, DEPurpose: Managing severe scoliosis is challenging and risky with a significant complication rate regardless of treatment strategy. In this retrospective comparative study, we report our results using a three-rod compared to two-rod construct in the surgical treatment of severe spine deformities to investigate which technique is safer, and which provides superior radiological outcomes. Methods: Forty-six consecutive patients undergoing posterior spine fusion for scoliosis between 2006 and 2017 were identified in our institutional records. Inclusion criteria were minimum coronal deformity of 90°, age < 18 years at the time of surgery and a minimum 2 years of follow-up. Radiographic and clinical parameters, as well as post-operative complications were compared between the two groups. Results: There were 21 patients in the three-rod group and 25 in the two-rod group. The mean preoperative major coronal deformity was 100°± 9 and 102°± 10 in the three-rod and two-rod, respectively (p = 0.6). The average major curve correction was 51% and 59% in three-rod and two-rod groups, respectively (p = 0.03). The post-operative thoracic kyphosis was 30°± 11 and 21°± 12 in the three-rod and the two-rod groups, respectively (p = 0.01). The surgical time was 476 ± 52 and 387 ± 84 min in three-rod and two-rod, respectively (p < 0.01). One patient in the two-rod cohort showed permanent post-operative sensory deficit. There were three unplanned returns to operating theater in the two-rod group. Conclusions: Coronal correction was better with two-rod, whereas sagittal balance was superior with three-rod. Both techniques achieved balanced spine treating severe scoliosis. The two-rod technique was associated with a higher likelihood of requiring revision surgery. Level of evidence: level 3.Item Open Access Responding to Intraoperative Neuromonitoring Changes During Pediatric Coronal Spinal Deformity Surgery(Global Spine Journal, 2019-05-01) Lewis, SJ; Wong, IHY; Strantzas, S; Holmes, LM; Vreugdenhil, I; Bensky, H; Nielsen, CJ; Zeller, R; Lebel, DE; de Kleuver, M; Germscheid, N; Alanay, A; Berven, S; Cheung, KMC; Ito, M; Polly, DW; Shaffrey, CI; Qiu, Y; Lenke, LGStudy Design: Retrospective case study on prospectively collected data. Objectives: The purpose of this explorative study was: 1) to determine if patterns of spinal cord injury could be detected through intra-operative neuromonitoring (IONM) changes in pediatric patients undergoing spinal deformity corrections, 2) to identify if perfusion based or direct trauma causes of IONM changes could be distinguished, 3) to observe the effects of the interventions performed in response to these events, and 4) to attempt to identify different treatment algorithms for the different causes of IONM alerts. Methods: Prospectively collected neuromonitoring data in pre-established forms on consecutive pediatric patients undergoing coronal spinal deformity surgery at a single center was reviewed. Real-time data was collected on IONM alerts with >50% loss in signal. Patients with alerts were divided into 2 groups: unilateral changes (direct cord trauma), and bilateral MEP changes (cord perfusion deficits). Results: A total of 97 pediatric patients involving 71 females and 26 males with a mean age of 14.9 (11-18) years were included in this study. There were 39 alerts in 27 patients (27.8% overall incidence). All bilateral changes responded to a combination of transfusion, increasing blood pressure, and rod removal. Unilateral changes as a result of direct trauma, mainly during laminotomies for osteotomies, improved with removal of the causative agent. Following corrective actions in response to the alerts, all cases were completed as planned. Signal returned to near baseline in 20/27 patients at closure, with no new neurological deficits in this series. Conclusion: A high incidence of alerts occurred in this series of cases. Dividing IONM changes into perfusion-based vs direct trauma directed treatment to the offending cause, allowing for safe corrections of the deformities. Patients did not need to recover IONM signal to baseline to have a normal neurological examination.