Browsing by Author "Taylor, Davis G"
Now showing 1 - 9 of 9
- Results Per Page
- Sort Options
Item Open Access A Novel Junctional Tether Weave Technique for Adult Spinal Deformity: 2-Dimensional Operative Video.(Operative neurosurgery (Hagerstown, Md.), 2019-02) Buell, Thomas J; Mullin, Jeffrey P; Nguyen, James H; Taylor, Davis G; Garces, Juanita; Mazur, Marcus D; Buchholz, Avery L; Shaffrey, Mark E; Yen, Chun-Po; Shaffrey, Christopher I; Smith, Justin SProximal junctional kyphosis (PJK) is a common problem after multilevel spine instrumentation for adult spinal deformity. Various anti-PJK techniques such as junctional tethers for ligamentous augmentation have been proposed. We present an operative video demonstrating technical nuances of junctional tether "weave" application. A 70-yr-old male with prior L2-S1 instrumented fusion presented with worsening back pain and posture. Imaging demonstrated pathological loss of lumbar lordosis (flat back deformity), proximal junctional failure, and pseudarthrosis. The patient had severe global and segmental sagittal malalignment, with sagittal vertical axis (SVA, C7-plumbline) measuring 22.3 cm, pelvic incidence (PI) 55°, lumbar lordosis (LL) 8° in kyphosis, pelvic tilt (PT) 30°, and thoracic kyphosis (TK) 6°. The patient gave informed consent for surgery and use of imaging for medical publication. Briefly, surgery first involved re-instrumentation with bilateral pedicle screws from T10 to S1. After right-sided iliac screw fixation (left-sided iliac screw fixation was not performed due to extensive prior iliac crest bone graft harvesting), we then completed a L2-3 Smith-Petersen osteotomy, extended L4 pedicle subtraction osteotomy, and L3-4 interbody arthrodesis with a 12° lordotic cage (9 × 14 × 40 mm). Cobalt Chromium rods were placed spanning the instrumentation bilaterally, and accessory supplemental rods spanning the PSO were attached. An anti-PJK junctional tether "weave" was then implemented using 4.5 mm polyethylene tape (Mersilene tape [Ethicon, Somerville, New Jersey]). Postoperative imaging demonstrated improved alignment (SVA 2.8 cm, PI 55°, LL 53°, PT 25°, TK 45°) and no significant neurological complications occurred during convalescence or at 6 mo postop.Item Open Access Alignment Risk Factors for Proximal Junctional Kyphosis and the Effect of Lower Thoracic Junctional Tethers for Adult Spinal Deformity.(World neurosurgery, 2019-01) Buell, Thomas J; Chen, Ching-Jen; Quinn, John C; Buchholz, Avery L; Mazur, Marcus D; Mullin, Jeffrey P; Nguyen, James H; Taylor, Davis G; Bess, Shay; Line, Breton G; Ames, Christopher P; Schwab, Frank J; Lafage, Virginie; Shaffrey, Christopher I; Smith, Justin SObjective
The aims of this retrospective cohort study were to 1) identify new alignment risk factors for proximal junctional kyphosis (PJK) in adult spinal deformity (ASD) patients with lower thoracic upper instrumented vertebra (UIV) and 2) determine the effect of junctional tethers on PJK and UIV alignment.Methods
We analyzed consecutive ASD patients who underwent posterior instrumented fusion with lower thoracic UIV (T9-T11). Posteriorly anchored junctional tethers were used more recently for ligamentous augmentation to prevent PJK. In addition to regional and global parameters, upper segmental lumbar lordosis (ULL) versus lower segmental lumbar lordosis and UIV angle (measured from UIV inferior endplate to horizontal) were assessed. Primary outcome of PJK was defined as proximal junctional angle >10° and >10° greater than the corresponding preoperative measurement. Univariable and multivariable analyses were performed.Results
The study cohort comprised 120 ASD patients (mean age, 67 years) with minimum 1-year follow-up. Preoperative ULL (P = 0.034) and UIV angle (P = 0.026) were associated with PJK. No independent preoperative alignment risk factors of PJK were identified in multivariable analysis. Tether use was protective against PJK (odds ratio, 0.063 [0.016-0.247]; P < 0.001). PJK in tethered patients was more common with greater postoperative ULL (P = 0.047) and UIV angle (P = 0.026).Conclusions
Junctional tethers significantly reduced PJK in ASD patients with lower thoracic UIV. In tethered patients, PJK was more common with greater postoperative lordosis of the upper lumbar spine and greater UIV angle. This finding suggests potential benefit of tethers to mitigate effects of segmental lumbar and focal UIV malalignment that may occur after deformity surgery.Item Open Access Letter to the Editor. Proximal junctional kyphosis and proximal junctional failure.(Journal of neurosurgery. Spine, 2018-11) Buell, Thomas J; Taylor, Davis G; Chen, Ching-Jen; Shaffrey, Christopher I; Smith, Justin S; Bess, ShayItem Open Access Low rates of complications after spinopelvic fixation with iliac screws in 260 adult patients with a minimum 2-year follow-up(Journal of Neurosurgery: Spine, 2019-05-01) Nguyen, James H; Buell, Thomas J; Wang, Tony R; Mullin, Jeffrey P; Mazur, Marcus D; Garces, Juanita; Taylor, Davis G; Yen, Chun-Po; Shaffrey, Christopher I; Smith, Justin SOBJECTIVE Recent literature describing complications associated with spinopelvic fixation with iliac screws in adult patients has been limited but has suggested high complication rates. The authors’ objective was to report their experience with iliac screw fixation in a large series of patients with a 2-year minimum follow-up. METHODS Of 327 adult patients undergoing spinopelvic fixation with iliac screws at the authors’ institution between 2010 and 2015, 260 met the study inclusion criteria (age ≥ 18 years, first-time iliac screw placement, and 2-year minimum follow-up). Patients with active spinal infection were excluded. All iliac screws were placed via a posterior midline approach using fluoroscopic guidance. Iliac screw heads were deeply recessed into the posterior superior iliac spine. Clinical and radiographic data were obtained and analyzed. RESULTS Twenty patients (7.7%) had iliac screw–related complication, which included fracture (12, 4.6%) and/or screw loosening (9, 3.5%). No patients had iliac screw head prominence that required revision surgery or resulted in pain, wound dehiscence, or poor cosmesis. Eleven patients (4.2%) had rod or connector fracture below S1. Overall, 23 patients (8.8%) had L5–S1 pseudarthrosis. Four patients (1.5%) had fracture of the S1 screw. Seven patients (2.7%) had wound dehiscence (unrelated to the iliac screw head) or infection. The rate of reoperation (excluding proximal junctional kyphosis) was 17.7%. On univariate analysis, an iliac screw–related complication rate was significantly associated with revision fusion (70.0% vs 41.2%, p = 0.013), a greater number of instrumented vertebrae (mean 12.6 vs 10.3, p = 0.014), and greater postoperative pelvic tilt (mean 27.7° vs 23.2°, p = 0.04). Lumbosacral junction–related complications were associated with a greater mean number of instrumented vertebrae (12.6 vs 10.3, p = 0.014). Reoperation was associated with a younger mean age at surgery (61.8 vs 65.8 years, p = 0.014), a greater mean number of instrumented vertebrae (12.2 vs 10.2, p = 0.001), and longer clinical and radiological mean follow-up duration (55.8 vs 44.5 months, p < 0.001; 55.8 vs 44.6 months, p < 0.001, respectively). On multivariate analysis, reoperation was associated with longer clinical follow-up (p < 0.001). CONCLUSIONS Previous studies on iliac screw fixation have reported very high rates of complications and reoperation (as high as 53.6%). In this large, single-center series of adult patients, iliac screws were an effective method of spinopelvic fixation that had high rates of lumbosacral fusion and far lower complication rates than previously reported. Collectively, these findings argue that iliac screw fixation should remain a favored technique for spinopelvic fixation.Item Open Access Postoperative Low-Dose Tranexamic Acid After Major Spine Surgery: A Matched Cohort Analysis.(Neurospine, 2020-12-31) Dunn, Lauren K; Chen, Ching-Jen; Taylor, Davis G; Esfahani, Kamilla; Brenner, Brian; Luo, Charles; Buell, Thomas J; Spangler, Sarah N; Buchholz, Avery L; Smith, Justin S; Shaffrey, Christopher I; Nemergut, Edward C; Durieux, Marcel E; Naik, Bhiken IObjective
This was a retrospective, cohort study investigating the efficacy and safety of continuous low-dose postoperative tranexamic acid (PTXA) on drain output and transfusion requirements following adult spinal deformity surgery.Methods
One hundred forty-seven patients undergoing posterior instrumented thoracolumbar fusion of ≥ 3 vertebral levels at a single institution who received low-dose PTXA infusion (0.5-1 mg/kg/hr) for 24 hours were compared to 292 control patients who did not receive PTXA. The cohorts were propensity matched based on age, sex, American Society of Anesthesiologist physical status classification, body mass index, number of surgical levels, revision surgery, operative duration, and total intraoperative TXA dose (n = 106 in each group). Primary outcome was 72-hour postoperative drain output. Secondary outcomes were number of allogeneic blood transfusions.Results
There was no significant difference in postoperative drain output in the PTXA group compared to control (660 ± 420 mL vs. 710 ± 490 mL, p = 0.46). The PTXA group received significantly more crystalloid (6,100 ± 3,100 mL vs. 4,600 ± 2,400 mL, p < 0.001) and red blood cell transfusions postoperatively (median [interquartile range]: 1 [0-2] units vs. 0 [0-1] units; incidence rate ratio [95% confidence interval], 1.6 [1.2-2.2]; p = 0.001). Rates of adverse events were comparable between groups.Conclusion
Continuous low-dose PTXA infusion was not associated with reduced drain output after spinal deformity surgery. No difference in thromboembolic incidence was observed. A prospective dose escalation study is warranted to investigate the efficacy of higher dose PTXA.Item Open Access Radiographic outcome and complications after single-level lumbar extended pedicle subtraction osteotomy for fixed sagittal malalignment: a retrospective analysis of 55 adult spinal deformity patients with a minimum 2-year follow-up.(Journal of neurosurgery. Spine, 2018-11) Buell, Thomas J; Nguyen, James H; Mazur, Marcus D; Mullin, Jeffrey P; Garces, Juanita; Taylor, Davis G; Yen, Chun-Po; Shaffrey, Mark E; Shaffrey, Christopher I; Smith, Justin SOBJECTIVEFixed sagittal spinal malalignment is a common problem in adult spinal deformity (ASD). Various three-column osteotomy techniques, including the extended pedicle subtraction osteotomy (ePSO), may correct global and regional malalignment in this patient population. In contrast to the number of reports on traditional PSO (Schwab grade 3 osteotomy), there is limited literature on the outcomes of ePSO (Schwab grade 4 osteotomy) in ASD surgery. The objective of this retrospective study was to provide focused investigation of radiographic outcomes and complications of single-level lumbar ePSO for ASD patients with fixed sagittal malalignment.METHODSConsecutive ASD patients in whom sagittal malalignment had been treated with single-level lumbar ePSO at the authors' institution between 2010 and 2015 were analyzed, and those with a minimum 2-year follow-up were included in the study. Radiographic analyses included assessments of segmental lordosis through the ePSO site (sagittal Cobb angle measured from the superior endplate of the vertebra above and inferior endplate of the vertebra below the ePSO), lumbar lordosis (LL), pelvic tilt (PT), pelvic incidence and LL mismatch, thoracic kyphosis (TK), and sagittal vertical axis (SVA) on standing long-cassette radiographs. Complications were analyzed for the entire group.RESULTSAmong 71 potentially eligible patients, 55 (77%) had a minimum 2-year follow-up and were included in the study. Overall, the average postoperative increases in ePSO segmental lordosis and overall LL were 41° ± 14° (range 7°-69°, p < 0.001) and 38° ± 11° (range 9°-58°, p < 0.001), respectively. The average SVA improvement was 13 ± 7 cm (range of correction: -33.6 to 3.4 cm, p < 0.001). These measurements were maintained when comparing early postoperative to last follow-up values, respectively (mean follow-up 52 months, range 26-97 months): ePSO segmental lordosis, 34° vs 33°, p = 0.270; LL, 47.3° vs 46.7°, p = 0.339; and SVA, 4 vs 5 cm, p = 0.330. Rod fracture (RF) at the ePSO site occurred in 18.2% (10/55) of patients, and pseudarthrosis (PA) at the ePSO site was confirmed by CT imaging or during rod revision surgery in 14.5% (8/55) of patients. Accessory supplemental rods across the ePSO site, a more recently employed technique, significantly reduced the occurrence of RF or PA on univariate (p = 0.004) and multivariable (OR 0.062, 95% CI 0.007-0.553, p = 0.013) analyses; this effect approached statistical significance on Kaplan-Meier analysis (p = 0.053, log-rank test). Interbody cage placement at the ePSO site resulted in greater ePSO segmental lordosis correction (45° vs 35°, p = 0.007) without significant change in RF or PA (p = 0.304). Transient and persistent motor deficits occurred in 14.5% (8/55) and 1.8% (1/55) of patients, respectively.CONCLUSIONSExtended PSO is an effective technique to correct fixed sagittal malalignment for ASD. In comparison to traditional PSO techniques, ePSO may allow greater focal correction with comparable complication rates, especially with interbody cage placement at the ePSO site and the use of accessory supplemental rods.Item Open Access Rotational thromboelastometry-guided transfusion during lumbar pedicle subtraction osteotomy for adult spinal deformity: preliminary findings from a matched cohort study.(Neurosurgical focus, 2019-04) Buell, Thomas J; Taylor, Davis G; Chen, Ching-Jen; Dunn, Lauren K; Mullin, Jeffrey P; Mazur, Marcus D; Yen, Chun-Po; Shaffrey, Mark E; Shaffrey, Christopher I; Smith, Justin S; Naik, Bhiken IOBJECTIVESignificant blood loss and coagulopathy are often encountered during adult spinal deformity (ASD) surgery, and the optimal intraoperative transfusion algorithm is debatable. Rotational thromboelastometry (ROTEM), a functional viscoelastometric method for real-time hemostasis testing, may allow early identification of coagulopathy and improve transfusion practices. The objective of this study was to investigate the effect of ROTEM-guided blood product management on perioperative blood loss and transfusion requirements in ASD patients undergoing correction with pedicle subtraction osteotomy (PSO).METHODSThe authors retrospectively reviewed patients with ASD who underwent single-level lumbar PSO at the University of Virginia Health System. All patients who received ROTEM-guided blood product transfusion between 2015 and 2017 were matched in a 1:1 ratio to a historical cohort treated using conventional laboratory testing (control group). Co-primary outcomes were intraoperative estimated blood loss (EBL) and total blood product transfusion volume. Secondary outcomes were perioperative transfusion requirements and postoperative subfascial drain output.RESULTSThe matched groups (ROTEM and control) comprised 17 patients each. Comparison of matched group baseline characteristics demonstrated differences in female sex and total intraoperative dose of intravenous tranexamic acid (TXA). Although EBL was comparable between ROTEM versus control (3200.00 ± 2106.24 ml vs 3874.12 ± 2224.22 ml, p = 0.36), there was a small to medium effect size (Cohen's d = 0.31) on EBL reduction with ROTEM. The ROTEM group had less total blood product transfusion volume (1624.18 ± 1774.79 ml vs 2810.88 ± 1847.46 ml, p = 0.02), and the effect size was medium to large (Cohen's d = 0.66). This difference was no longer significant after adjusting for TXA (β = -0.18, 95% confidence interval [CI] -1995.78 to 671.64, p = 0.32). More cryoprecipitate and less fresh frozen plasma (FFP) were transfused in the ROTEM group patients (cryoprecipitate units: 1.24 ± 1.20 vs 0.53 ± 1.01, p = 0.03; FFP volume: 119.76 ± 230.82 ml vs 673.06 ± 627.08 ml, p < 0.01), and this remained significant after adjusting for TXA (cryoprecipitate units: β = 0.39, 95% CI 0.05 to 1.73, p = 0.04; FFP volume: β = -0.41, 95% CI -772.55 to -76.30, p = 0.02). Drain output was lower in the ROTEM group and remained significant after adjusting for TXA.CONCLUSIONSFor ASD patients treated using lumbar PSO, more cryoprecipitate and less FFP were transfused in the ROTEM group compared to the control group. These preliminary findings suggest ROTEM-guided therapy may allow early identification of hypofibrinogenemia, and aggressive management of this may reduce blood loss and total blood product transfusion volume. Additional prospective studies of larger cohorts are warranted to identify the appropriate subset of ASD patients who may benefit from intraoperative ROTEM analysis.Item Open Access Utility of topical tranexamic acid for adult patients with spinal deformity and contraindications to systemic tranexamic acid: Initial experience and report of 2 cases(Journal of Neurosurgery: Spine, 2019-04-01) Desai, Bhargav D; Taylor, Davis G; Chen, Ching-Jen; Buell, Thomas J; Mullin, Jeffrey P; Naik, Bhiken I; Smith, Justin S; Shaffrey, Christopher ITranexamic acid (TXA) is an antifibrinolytic agent with demonstrated efficacy in reducing blood loss when administered systemically. However, in patients with contraindications to systemic or intravenous TXA, topical TXA (tTXA) has been shown to reduce perioperative blood loss, with some studies suggesting equivalence compared to systemic TXA. However, these studies have been conducted in healthy cohorts without contraindications to systemic TXA. In the surgical management of adult spinal deformity (ASD), comorbid disease is commonly encountered and may preclude use of systemic TXA. In this subset of patients with ASD who have contraindications for systemic TXA, use of tTXA has not been reported. The primary objective of this study was to conduct a systematic review on the use of tTXA in spine surgery and to present the authors' initial experience with tTXA as a novel hemostatic technique for 2 patients with medically complex ASD. Both patients had contraindications to systemic TXA use and underwent high-risk, long-segment fusion operations for correction of ASD. Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines were used to obtain studies related to spine surgery and tTXA from the National Institutes of Health PubMed (www.pubmed. gov) database. Criteria for final selection included a demonstration of quantitative data regarding operative or postoperative blood loss with the use of tTXA, and selection criteria were met by 6 articles. Topical TXA may offer a potential therapeutic role in reducing intra- and postoperative blood loss following long-segment spinal fusion surgeries, particularly for medically complex patients with contraindications to systemic TXA. It is reasonable to consider the use of tTXA as a salvage technique in complex high-risk patients with contraindications to systemic TXA, although further research is needed to delineate safety, magnitude of benefit, and optimization of dosing.Item Open Access Ventilator Mode Does Not Influence Blood Loss or Transfusion Requirements During Major Spine Surgery: A Retrospective Study.(Anesthesia and analgesia, 2020-01) Dunn, Lauren K; Taylor, Davis G; Chen, Ching-Jen; Singla, Priyanka; Fernández, Lucas; Wiedle, Christopher H; Hanak, Mark F; Tsang, Siny; Smith, Justin S; Shaffrey, Christopher I; Nemergut, Edward C; Durieux, Marcel E; Blank, Randal S; Naik, Bhiken IBackground
Blood loss during adult spinal deformity surgery is multifactorial. Anesthetic-related factors, such as mode of mechanical ventilation, may contribute to intraoperative blood loss. The aim of this study was to determine the influence of ventilator mode and ventilator parameters on intraoperative blood loss and transfusion requirements in patients undergoing prone position spine surgery.Methods
This single-center retrospective study examined electronic medical records of patients ≥18 years of age who underwent elective prone position spine surgery between May 2015 and June 2016. Associations between ventilator mode and ventilator parameters with intraoperative estimated blood loss (EBL), packed red blood cells (PRBCs), fresh-frozen plasma (FFP), cryoprecipitate and platelet transfusions, and subfascial drain output were examined using multiple linear regression models controlling for age, sex, American Society of Anesthesiologist (ASA) physical status score, body mass index (BMI), preoperative blood coagulation parameters and laboratory values, operative levels, cage constructs, osteotomies, transforaminal lumbar interbody fusions, laminectomies, reoperation, spine surgery invasiveness index, and operative time. In a secondary analysis, EBL, blood product transfusions, and postoperative drain output were compared between pressure-controlled ventilation (PCV) and volume-controlled ventilation (VCV) propensity score-matched cohorts.Results
Nine hundred forty-six records were reviewed, and 822 were included in the analysis. After adjusting for confounding, no statistically significant associations were observed between mode of ventilation and intraoperative EBL (estimate, -2; 95% confidence interval [CI], -248 to 245; P = .99) or blood product transfusions (PRBC: estimate, -9; 95% CI, -154 to 135; P = .90; FFP: estimate, -3; 95% CI, -59 to 54; P = .93; cryoprecipitate: estimate, -14; 95% CI, -70 to 43; P = .63; platelets: -7; 95% CI, -39 to 24; P = .64). After propensity score matching (n = 27 per group), no significant differences were observed in EBL (mean difference, 525 mL; 95% CI, -15 to 1065; P = .056) or blood transfusions (PRBC: mean difference, 208 mL; 95% CI, -23 to 439; P = .077; FFP (mean difference, 34 mL; 95% CI, -17 to 84; P = .19); cryoprecipitate (mean difference, 55 mL; 95% CI, -24 to 133; P = .17); or platelets (mean difference, 26 mL; 95% CI, -12 to 64; P = .18) between PCV and VCV groups.Conclusions
In prone position spine surgery, neither mode of mechanical ventilation nor airway pressure is associated with intraoperative blood loss or need for allogeneic transfusion. Use of modern ventilation strategies using lung protective techniques may mitigate differences in blood loss previously observed between PCV and VCV modes.