Item Open Access Ablation Versus Drug Therapy for Atrial Fibrillation in Racial and Ethnic Minorities.(Journal of the American College of Cardiology, 2021-07) Thomas, Kevin L; Al-Khalidi, Hussein R; Silverstein, Adam P; Monahan, Kristi H; Bahnson, Tristram D; Poole, Jeanne E; Mark, Daniel B; Packer, Douglas L; CABANA InvestigatorsBackground
Rhythm control strategies for atrial fibrillation (AF), including catheter ablation, are substantially underused in racial/ethnic minorities in North America.Objectives
This study sought to describe outcomes in the CABANA trial as a function of race/ethnicity.Methods
CABANA randomized 2,204 symptomatic participants with AF to ablation or drug therapy including rate and/or rhythm control drugs. Only participants in North America were included in the present analysis, and participants were subgrouped as racial/ethnic minority or nonminority with the use of National Institutes of Health definitions. The primary endpoint was a composite of death, disabling stroke, serious bleeding, or cardiac arrest.Results
Of 1,280 participants enrolled in CABANA in North America, 127 (9.9%) were racial and ethnic minorities. Compared with nonminorities, racial and ethnic minorities were younger with median age 65.6 versus 68.5 years, respectively, and had more symptomatic heart failure (37.0% vs 22.0%), hypertension (92.1% vs 76.8%, respectively), and ejection fraction <40% (20.8% vs 7.1%). Racial/ethnic minorities treated with ablation had a 68% relative reduction in the primary endpoint (adjusted hazard ratio [aHR]: 0.32; 95% confidence interval [CI]: 0.13-0.78) and a 72% relative reduction in all-cause mortality (aHR: 0.28; 95% CI: 0.10-0.79). Primary event rates in racial/ethnic minority and nonminority participants were similar in the ablation arm (4-year Kaplan-Meier event rates 12.3% vs 9.9%); however, racial and ethnic minorities randomized to drug therapy had a much higher event rate than nonminority participants (27.4% vs. 9.4%).Conclusion
Among racial or ethnic minorities enrolled in the North American CABANA cohort, catheter ablation significantly improved major clinical outcomes compared with drug therapy. These benefits, which were not seen in nonminority participants, appear to be due to worse outcomes with drug therapy. (Catheter Ablation vs Anti-arrhythmic Drug Therapy for Atrial Fibrillation Trial [CABANA]; NCT00911508).Item Open Access Assessment of the quality of existing patient educational tools focused on sudden cardiac arrest: a systematic evaluation by the Sudden Cardiac Arrest Thought Leadership Alliance.(Patient Prefer Adherence, 2013) Hazelton, Garrett; Al-Khatib, Sana M; Fonarow, Gregg C; Thomas, Kevin L; Hayes, David; Sanders, Gillian D; Campbell, Susan M; Yancy, Clyde; Peterson, Eric D; Sears, SamuelBACKGROUND: Conveying contemporary treatment options for those at risk of sudden cardiac arrest (SCA) is challenging. The purpose of the present research was to evaluate the quality and usability of available patient educational tools relevant to SCA and its treatment options, such as implantable cardioverter defibrillators (ICDs). We hypothesized that this review would identify gaps in areas of information for the enhancement of patient education and decision-making materials. METHODS: We used a formal instrument to assess specific domains of content, development, and effectiveness of 18 available SCA and ICD educational tools. The multidisciplinary review panel included two electrophysiologists, two general cardiologists, a cardiac psychologist, a health services researcher, and a patient advocate. RESULTS: Of the 18 education tools, four were rated as "good, may need revisions, but sufficient for use", 12 were rated as "marginal, needs revision prior to use", and two were rated as "poor, inadequate for use". None of the tools were rated as being of "very good" or "excellent" quality. CONCLUSION: There appear to be opportunities to improve the quality and completeness of existing educational tools for patients with SCA and ICD. While many tools have been developed, they fall below current standards for supporting informed medical decision-making.Item Open Access Catheter ablation of atrial fibrillation in patients with diabetes mellitus.(Heart rhythm O2, 2020-08) Wang, Allen; Truong, Tracy; Black-Maier, Eric; Green, Cynthia; Campbell, Kristen B; Barnett, Adam S; Febre, Janice; Loring, Zak; Al-Khatib, Sana M; Atwater, Brett D; Daubert, James P; Frazier-Mills, Camille; Hegland, Donald D; Jackson, Kevin P; Jackson, Larry R; Koontz, Jason I; Lewis, Robert K; Pokorney, Sean D; Sun, Albert Y; Thomas, Kevin L; Bahnson, Tristam D; Piccini, Jonathan PBackground
Diabetes mellitus (DM) is an independent risk factor for atrial fibrillation (AF). Few studies have compared clinical outcomes after catheter ablation between patients with and those without DM.Objective
The purpose of this study was to compare AF ablation outcomes in patients with and those without DM.Methods
We performed a retrospective analysis of 351 consecutive patients who underwent first-time AF ablation. Clinical outcomes included freedom from recurrent atrial arrhythmia, symptom burden (Mayo AF Symptom Inventory score), cardiovascular and all-cause hospitalizations, and periprocedural complications.Results
Patients with DM (n = 65) were older, had a higher body mass index, more persistent AF, more hypertension, and larger left atrial diameter (P <.05 for all). Median (Q1, Q3) total radiofrequency duration [64.0 (43.6, 81.4) minutes vs 54.3 (39.2, 76.4) minutes; P = .132] and periprocedural complications (P = .868) did not differ between patients with and those without DM. After a median follow-up of 29.5 months, arrhythmia recurrence was significantly higher in the DM group compared to the no-DM group after adjustment for baseline differences (adjusted hazard ratio [HR] 2.24; 95% confidence [CI] 1.42-3.55; P = .001). There was a nonsignificant trend toward higher AF recurrence with worse glycemic levels (HR 1.29; 95% CI 0.99-1.69; P = .064).Conclusion
Although safety outcomes associated with AF ablation were similar between patients with and those without DM, arrhythmia-free survival was significantly lower among patients with DM. Poor glycemic control seems to an important risk factor for AF recurrence.Item Open Access Effectiveness of catheter ablation of atrial fibrillation according to heart failure etiology.(Journal of arrhythmia, 2020-02) Black-Maier, Eric; Steinberg, Benjamin A; Trulock, Kevin M; Wang, Frances; Lokhnygina, Yuliya; O'Neal, Wanda; Al-Khatib, Sana; Atwater, Brett D; Daubert, James P; Frazier-Mills, Camille; Hegland, Donald D; Jackson, Kevin P; Jackson, Larry R; Koontz, Jason I; Lewis, Robert K; Sun, Albert Y; Thomas, Kevin L; Bahnson, Tristram D; Piccini, Jonathan PBackground
Catheter ablation is an important rhythm control therapy in patients with atrial fibrillation (AF) with concomitant heart failure (HF). The objective of this study was to assess the comparative efficacy of AF ablation patients with ischemic vs nonischemic heart failure.Methods
We conducted a retrospective, observational cohort study of patients with HF who underwent AF ablation. Outcomes were compared based on HF etiology and included in-hospital events, symptoms (Mayo AF Symptom Inventory [MAFSI]), and functional status (New York Heart Association class) and freedom from atrial arrhythmias at 12 months.Results
Among 242 patients (n = 70 [29%] ischemic, n = 172 [71%] nonischemic), patients with nonischemic cardiomyopathy were younger (mean age 64 ± 11.5 vs 69 ± 9.1, P = .002), more often female (36% vs 17%, P = .004), and had higher mean left-ventricular ejection fraction (47% vs 42%, P = .0007). There were no significant differences in periprocedural characteristics, including mean procedure time (243 ± 74.2 vs 259 ± 81.8 minutes, P = .1) and nonleft atrial ablation (17% vs 20%, P = .6). All-cause adverse events were similar in each group (15% vs 17%, P = .7). NYHA and MAFSI scores improved significantly at follow-up and did not differ according to HF etiology (P = .5; P = .10-1.00 after Bonferroni correction). There were no significant differences in freedom from recurrent atrial arrhythmia at 12-months between ischemic (74%) and nonischemic patients (78%): adjusted RR 0.63, 95% confidence interval 0.33-1.19.Conclusions
Catheter ablation in patients with AF and concomitant heart failure leads to significant improvements in functional and symptom status without significant differences between patients with ischemic vs nonischemic HF etiology.Item Open Access Optimizing mechanically sensed atrial tracking in patients with atrioventricular-synchronous leadless pacemakers: A single-center experience.(Heart rhythm O2, 2021-10) Arps, Kelly; Piccini, Jonathan P; Yapejian, Rebecca; Leguire, Rhonda; Smith, Brenda; Al-Khatib, Sana M; Bahnson, Tristram D; Daubert, James P; Hegland, Donald D; Jackson, Kevin P; Jackson, Larry R; Lewis, Robert K; Pokorney, Sean D; Sun, Albert Y; Thomas, Kevin L; Frazier-Mills, CamilleBackground
Atrioventricular (AV)-synchronous single-chamber leadless pacing using a mechanical atrial sensing algorithm produced high AV synchrony in clinical trials, but clinical practice experience with these devices has not yet been described.Objective
To describe pacing outcomes and programming changes with AV-synchronous leadless pacemakers in clinical practice.Methods
Consecutive patients without persistent atrial fibrillation who received an AV-synchronous leadless pacemaker and completed follow-up between February 2020 and April 2021 were included. We evaluated tracking index (atrial mechanical sense followed by ventricular pace [AM-VP] divided by total VP), total AV synchrony (sum of AM-ventricular sense [AM-VS], AM-VP, and AV conduction mode switch), use of programming optimization, and improvement in AV synchrony after optimization.Results
Fifty patients met the inclusion criteria. Mean age was 69 ± 16.8 years, 24 (48%) were women, 24 (48%) had complete heart block, and 17 (34%) required ≥50% pacing. Mean tracking index was 41% ± 34%. Thirty-five patients (70%) received ≥1 programming change. In 36 patients with 2 follow-up visits, tracking improved by +9% ± 28% (P value for improvement = .09) and +18% ± 19% (P = .02) among 15 patients with complete heart block. Average total AV synchrony increased from 89% [67%, 99%] to 93% [78%, 100%] in all patients (P = .22), from 86% [52%, 98%] to 97% [82%, 99%] in those with complete heart block (P = .04), and from 73% [52%, 80%] to 78% [70%, 85%] in those with ≥50% pacing (P = .09).Conclusion
In patients with AV-synchronous leadless pacemakers, programming changes are frequent and are associated with increased atrial tracking and increased AV synchrony in patients with complete heart block.Item Open Access Predicting atrial fibrillation recurrence after ablation in patients with heart failure: Validity of the APPLE and CAAP-AF risk scoring systems.(Pacing and clinical electrophysiology : PACE, 2019-11) Black-Maier, Eric; Parish, Alice; Steinberg, Benjamin A; Green, Cynthia L; Loring, Zak; Barnett, Adam S; Al-Khatib, Sana M; Atwater, Brett D; Daubert, James P; Frazier-Mills, Camille; Hegland, Donald D; Jackson, Kevin P; Jackson, Larry R; Koontz, Jason; Lewis, Robert K; Pokorney, Sean D; Sun, Albert Y; Thomas, Kevin L; Bahnson, Tristam D; Piccini, Jonathan PBackground
Compared with medical therapy, catheter ablation of atrial fibrillation (AF) in patients with heart failure (HF) improves cardiovascular outcomes. Risk scores (CAAP-AF and APPLE) have been developed to predict the likelihood of AF recurrence after ablation, have not been validated specifically in patients with AF and HF.Methods
We analyzed baseline characteristics, risk scores, and rates of AF recurrence 12 months postablation in a cohort of 230 consecutive patients with AF and HF undergoing PVI in the Duke Center for Atrial Fibrillation registry from 2009-2013.Results
During a follow-up period of 12 months, 76 of 230 (33%) patients with HF experienced recurrent AF after ablation. The median APPLE and CAAP-AF scores were 1.5 ([Q1, Q3]: [1.0, 2.0]) and 4.0 ([Q1, Q3]: [3.0, 5.0]), respectively and were not different from those patients with and without recurrent AF. Freedom from AF was not different according to APPLE and CAAP-AF scores. Discrimination for recurrent AF with the CAAP-AF score was modest with a C-statistic of 0.60 (95% CI 0.52-0.67). Discrimination with the APPLE score was similarly modest, with a C-statistic of 0.54 (95% CI: 0.47-0.62).Conclusions
Validated predictive risk scores for recurrent AF after catheter ablation exhibit limited predictive ability in cohorts of AF and HF. Additional tools are needed to facilitate risk stratification and patient selection for AF ablation in patients with concomitant HF.Item Open Access Race and Sex Differences in QRS Interval and Associated Outcome Among Patients with Left Ventricular Systolic Dysfunction.(J Am Heart Assoc, 2017-03-20) Randolph, Tiffany C; Broderick, Samuel; Shaw, Linda K; Chiswell, Karen; Mentz, Robert J; Kutyifa, Valentina; Velazquez, Eric J; Gilliam, Francis R; Thomas, Kevin LBACKGROUND: Prolonged QRS duration is associated with increased mortality among heart failure patients, but race or sex differences in QRS duration and associated effect on outcomes are unknown. METHODS AND RESULTS: We investigated QRS duration and morphology among 2463 black and white patients with heart failure and left ventricular ejection fraction ≤35% who underwent coronary angiography and 12-lead electrocardiography at Duke University Hospital from 1995 through 2011. We used multivariable Cox regression models to assess the relationship between QRS duration and all-cause mortality and investigate race-QRS and sex-QRS duration interaction. Median QRS duration was 105 ms (interquartile range [IQR], 92-132) with variation by race and sex (P<0.001). QRS duration was longest in white men (111 ms; IQR, 98-139) followed by white women (108 ms; IQR, 92-140), black men (100 ms; IQR, 91-120), and black women (94 ms; IQR, 86-118). Left bundle branch block was more common in women than men (24% vs 14%) and in white (21%) versus black individuals (12%). In black patients, there was a 16% increase in risk of mortality for every 10 ms increase in QRS duration up to 112 ms (hazard ratio, 1.16; 95% CI, 1.07, 1.25) that was not present among white patients (interaction, P=0.06). CONCLUSIONS: Black individuals with heart failure had a shorter QRS duration and more often had non-left bundle branch block morphology than white patients. Women had left bundle branch block more commonly than men. Among black patients, modest QRS prolongation was associated with increased mortality.Item Open Access Racial and Ethnic Differences in Treatment and Outcomes of Severe Aortic Stenosis: A Review.(JACC. Cardiovascular interventions, 2020-01) Wilson, Jimica B; Jackson, Larry R; Ugowe, Francis E; Jones, Terrell; Yankey, George SA; Marts, Colin; Thomas, Kevin LAortic stenosis (AS) is among the most common valvular heart diseases encountered in the United States. In this review the authors examine differences between racial and ethnic groups in the epidemiology and management of severe AS, explore potential explanations for these findings, and discuss the implications for improving the delivery of care to racially and ethnically diverse populations. Underrepresented racial and ethnic groups experience a paradoxically lower prevalence or incidence of AS relative to white subjects, despite having a higher prevalence of traditional risk factors. Historically, UREGs with severe AS have had lower rates of both surgical and transcatheter aortic valve replacement and experienced more post-surgical complications, including, bleeding, worsening heart failure, and rehospitalization. Last, UREGs with severe AS have an increased risk for morbidity and mortality relative to white patients. To date much of the research on AS has examined black-white differences, so there is a need to understand how other racial and ethnic groups with severe AS are diagnosed and treated, with examination of their resulting outcomes. Overall, racial and ethnic disparities in health care access and care delivery are a public health concern given the changing demographics of the U.S. population. These differences in AS management and outcomes highlight the need for additional research into contributing factors and appropriate interventions to address the lower rates of aortic valve replacement and higher morbidity and mortality among UREGs.Item Open Access Racial differences in the prevalence and outcomes of atrial fibrillation among patients hospitalized with heart failure.(J Am Heart Assoc, 2013-09-26) Thomas, Kevin L; Piccini, Jonathan P; Liang, Li; Fonarow, Gregg C; Yancy, Clyde W; Peterson, Eric D; Hernandez, Adrian F; Get With the Guidelines Steering Committee and HospitalsBACKGROUND: The intersection of heart failure (HF) and atrial fibrillation (AF) is common, but the burden of AF among black patients with HF is poorly characterized. We sought to determine the prevalence of AF, characteristics, in-hospital outcomes, and warfarin use associated with AF in patients hospitalized with HF as a function of race. METHODS AND RESULTS: We analyzed data on 135 494 hospitalizations from January 2006 through January 2012 at 276 hospitals participating in the American Heart Association's Get With The Guidelines HF Program. Multivariable logistic regression models using generalized estimating equations approach for risk-adjusted comparison of AF prevalence, in-hospital outcomes, and warfarin use. In this HF population, 53 389 (39.4%) had AF. Black patients had markedly less AF than white patients (20.8% versus 44.8%, P < 0.001). Adjusting for risk factors and hospital characteristics, black race was associated with significantly lower odds of AF (adjusted odds ratio 0.52, 95% CI 0.48 to 0.55, P < 0.0001). There were no racial differences in in-hospital mortality; however, black patients had a longer length of stay relative to white patients. Black patients compared with white patients with AF were less likely to be discharged on warfarin (adjusted odds ratio 0.76, 95% CI 0.69 to 0.85, P < 0.001). CONCLUSIONS: Despite having many risk factors for AF, black patients, relative to white patients hospitalized for HF, had a lower prevalence of AF and lower prescription of guideline-recommended warfarin therapy.Item Open Access Ventricular conduction and long-term heart failure outcomes and mortality in African Americans: insights from the Jackson Heart Study.(Circ Heart Fail, 2015-03) Mentz, Robert J; Greiner, Melissa A; DeVore, Adam D; Dunlay, Shannon M; Choudhary, Gaurav; Ahmad, Tariq; Khazanie, Prateeti; Randolph, Tiffany C; Griswold, Michael E; Eapen, Zubin J; O'Brien, Emily C; Thomas, Kevin L; Curtis, Lesley H; Hernandez, Adrian FBACKGROUND: QRS prolongation is associated with adverse outcomes in mostly white populations, but its clinical significance is not well established for other groups. We investigated the association between QRS duration and mortality in African Americans. METHODS AND RESULTS: We analyzed data from 5146 African Americans in the Jackson Heart Study stratified by QRS duration on baseline 12-lead ECG. We defined QRS prolongation as QRS≥100 ms. We assessed the association between QRS duration and all-cause mortality using Cox proportional hazards models and reported the cumulative incidence of heart failure hospitalization. We identified factors associated with the development of QRS prolongation in patients with normal baseline QRS. At baseline, 30% (n=1528) of participants had QRS prolongation. The cumulative incidences of mortality and heart failure hospitalization were greater with versus without baseline QRS prolongation: 12.6% (95% confidence interval [CI], 11.0-14.4) versus 7.1% (95% CI, 6.3-8.0) and 8.2% (95% CI, 6.9-9.7) versus 4.4% (95% CI, 3.7-5.1), respectively. After risk adjustment, QRS prolongation was associated with increased mortality (hazard ratio, 1.27; 95% CI, 1.03-1.56; P=0.02). There was a linear relationship between QRS duration and mortality (hazard ratio per 10 ms increase, 1.06; 95% CI, 1.01-1.12). Older age, male sex, prior myocardial infarction, lower ejection fraction, left ventricular hypertrophy, and left ventricular dilatation were associated with the development of QRS prolongation. CONCLUSIONS: QRS prolongation in African Americans was associated with increased mortality and heart failure hospitalization. Factors associated with developing QRS prolongation included age, male sex, prior myocardial infarction, and left ventricular structural abnormalities.