Browsing by Author "Zeitler, Emily P"
Now showing 1 - 4 of 4
- Results Per Page
- Sort Options
Item Open Access Association Between Sex and Treatment Outcomes of Atrial Fibrillation Ablation Versus Drug Therapy: Results From the CABANA Trial.(Circulation, 2021-02) Russo, Andrea M; Zeitler, Emily P; Giczewska, Anna; Silverstein, Adam P; Al-Khalidi, Hussein R; Cha, Yong-Mei; Monahan, Kristi H; Bahnson, Tristram D; Mark, Daniel B; Packer, Douglas L; Poole, Jeanne E; CABANA InvestigatorsBackground
Among patients with atrial fibrillation (AF), women are less likely to receive catheter ablation and may have more complications and less durable results. Most information about sex-specific differences after ablation comes from observational data. We prespecified an examination of outcomes by sex in the 2204-patient CABANA trial (Catheter Ablation Versus Antiarrhythmic Drug Therapy for Atrial Fibrillation).Methods
CABANA randomized patients with AF age ≥65 years or <65 years with ≥1 risk factor for stroke to a strategy of catheter ablation with pulmonary vein isolation versus drug therapy with rate/rhythm control agents. The primary composite outcome was death, disabling stroke, serious bleeding, or cardiac arrest, and key secondary outcomes included AF recurrence.Results
CABANA randomized 819 (37%) women (ablation 413, drug 406) and 1385 men (ablation 695, drug 690). Compared with men, women were older (median age, 69 years versus 67 years for men), were more symptomatic (48% Canadian Cardiovascular Society AF Severity Class 3 or 4 versus 39% for men), had more symptomatic heart failure (42% with New York Heart Association Class ≥II versus 32% for men), and more often had a paroxysmal AF pattern at enrollment (50% versus 39% for men) (P<0.0001 for all). Women were less likely to have ancillary (nonpulmonary vein) ablation procedures performed during the index procedure (55.7% versus 62.2% in men, P=0.043), and complications from treatment were infrequent in both sexes. For the primary outcome, the hazard ratio for those who underwent ablation versus drug therapy was 1.01 (95% CI, 0.62-1.65) in women and 0.73 (95% CI, 0.51-1.05) in men (interaction P value=0.299). The risk of recurrent AF was significantly reduced in patients undergoing ablation compared with those receiving drug therapy regardless of sex, but the effect was greater in men (hazard ratio, 0.64 [95% CI, 0.51-0.82] for women versus hazard ratio, 0.48 [95% CI, 0.40-0.58] for men; interaction P value=0.060).Conclusions
Clinically relevant treatment-related strategy differences in the primary and secondary clinical outcomes of CABANA were not seen between men and women, and there were no sex differences in adverse events. The CABANA trial results support catheter ablation as an effective treatment strategy for both women and men. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT00911508.Item Open Access Cable externalization and electrical failure of the Riata family of implantable cardioverter-defibrillator leads: A systematic review and meta-analysis.(Heart rhythm, 2015-06) Zeitler, Emily P; Pokorney, Sean D; Zhou, Ke; Lewis, Robert K; Greenfield, Ruth Ann; Daubert, James P; Matchar, David B; Piccini, Jonathan PBackground
The Riata class of defibrillator leads were placed under US Food and Drug Association (FDA) advisory as of November 2011 because of high rates of cable externalization (CE) and electrical failure (EF). The overall rates of these complications remain unknown.Objective
The purpose of this study was to systematically search the literature for rates of Riata lead failure and to perform a meta-analysis to estimate failure rates.Methods
We conducted a meta-analysis of observational studies examining the rates of EF, CE, and the interaction of the two. We identified 23 English language manuscripts addressing 1 or more of these questions.Results
Across 23 studies, the overall CE rate was 23.1% (95% confidence interval [CI] 19.0%-27.6%). The overall EF rate was 6.3% (95% CI 4.7%-8.2%). The presence of CE was associated with a more than 6-fold increase in the rate of EF compared to no CE (17.3% [95% CI 11.2%-25.9%] vs 2.7% [95% CI 1.4%-5.2%], respectively). The rate of CE was 3-fold higher for 8Fr leads compared to 7Fr leads, but rates of EF were similar (4.6%; 95% CI 3.2-6.6] and 3.9%; 95% CI 2.4-6.1], respectively). Rates of both CE and EF were higher in dual coil vs single coil leads, but confidence intervals overlapped.Conclusion
In clinical practice, rates of CE in Riata leads are substantial. While CE is associated with a significant increase in the risk of EF, the incidence of EF without externalization is not trivial.Item Open Access Effects of Ablation Versus Drug Therapy on Quality of Life by Sex in Atrial Fibrillation: Results From the CABANA Trial.(Journal of the American Heart Association, 2023-02) Zeitler, Emily P; Li, Yanhong; Silverstein, Adam P; Russo, Andrea M; Poole, Jeanne E; Daniels, Melanie R; Al-Khalidi, Hussein R; Lee, Kerry L; Bahnson, Tristram D; Anstrom, Kevin J; Packer, Douglas L; Mark, Daniel B; CABANA InvestigatorsBackground Women with atrial fibrillation (AF) demonstrate more AF-related symptoms and worse quality of life (QOL). Whether increased use of ablation in women reduces sex-related QOL differences is unknown. Sex-related outcomes for ablation versus drug therapy was a prespecified analysis in the CABANA (Catheter Ablation Versus Antiarrhythmic Drug Therapy for Atrial Fibrillation) trial. Methods and Results Symptoms were assessed periodically over 60 months with the Mayo AF-Specific Symptom Inventory (MAFSI) frequency score, and QOL was assessed with the Atrial Fibrillation Effect on Quality of Life (AFEQT) summary and component scores. Women had lower baseline QOL scores than men (mean AFEQT scores 55.9 and 65.6, respectively). Ablation patients improved more than drug therapy patients with similar treatment effect by sex: AFEQT 12-month mean adjusted treatment difference in women 6.1 points (95% CI, 3.5-8.6) and men 4.9 points (95% CI, 3.0-6.9). Participants with baseline AFEQT summary scores <70 had greater QOL improvement, with a mean treatment difference at 12 months of 7.6 points for women (95% CI, 4.3-10.9) and 6.4 points for men (95% CI, 3.3-9.4). The mean adjusted difference in MAFSI frequency score between women randomized to ablation versus drug therapy at 12 months was -2.5 (95% CI, -3.4 to -1.6); for men, the difference was -1.3 (95% CI, -2.0 to -0.6). Conclusions Compared with drug therapy for AF, ablation resulted in more QOL improvement in both sexes, primarily driven by improvements in those with lower baseline QOL. Ablation did not eliminate the AF-related QOL gap between women and men. Registration URL: https://www.clinicaltrials.gov; Unique identifier: NCT00911508.Item Open Access Optimal management of Riata leads with no known electrical abnormalities or externalization: a decision analysis.(Journal of cardiovascular electrophysiology, 2015-02) Pokorney, Sean D; Zhou, Ke; Matchar, David B; Love, Sean; Zeitler, Emily P; Lewis, Robert; Piccini, Jonathan PIntroduction
Riata and Riata ST implantable cardioverter-defibrillator (ICD) leads (St. Jude Medical, Sylmar, CA, USA) can develop conductor cable externalization and/or electrical failure. Optimal management of these leads remains unknown.Methods and results
A Markov model compared 4 lead management strategies: (1) routine device interrogation for electrical failure, (2) systematic yearly fluoroscopic screening and routine device interrogation, (3) implantation of new ICD lead with capping of the in situ lead, and (4) implantation of new ICD lead with extraction of the in situ lead. The base case was a 64-year-old primary prevention ICD patient. Modeling demonstrated average life expectancies as follows: capping with new lead implanted at 134.5 months, extraction with new lead implanted at 134.0 months, fluoroscopy with routine interrogation at 133.9 months, and routine interrogation at 133.5 months. One-way sensitivity analyses identified capping as the preferred strategy with only one parameter having a threshold value: when risk of nonarrhythmic death associated with lead abandonment is greater than 0.05% per year, lead extraction is preferred over capping. A second-order Monte Carlo simulation (n = 10,000), as a probabilistic sensitivity analysis, found that lead revision was favored with 100% certainty (extraction 76% and capping 24%).Conclusions
Overall there were minimal differences in survival with monitoring versus active lead management approaches. There is no evidence to support fluoroscopic screening for externalization of Riata or Riata ST leads.