Item Open Access CT Radiation Dosimetry Study using Monte Carlo Simulation and Computational Anthropomorphic Phantoms(2012) Zhang, YakunThere are three main x-ray based modalities for imaging the thorax: radiography, tomosynthesis, and computed tomography (CT). CT perhaps provides the highest level of feature resolution but at notably higher radiation dose, which has increased the concern among radiation protection professionals. Being able to accurately assess the radiation dose patients receive during CT procedures is a crucial step in the management of CT dose. To identify the best imaging modality for patients, the American College of Radiology published the guiding principle of "The right exam, for the right reason, at the right time". To implement this principle in making an appropriate choice between standard chest projection imaging, tomosynthesis, and CT, the organ and effective dose for each modality should be accurately known. This thesis work attempted to explain the effect on dose results when choosing different types of computational phantoms used in CT dosimetry; this work also compared radiation dose across three main x-ray based modalities on one common platform for different body shape adults.
The first part of this thesis compared organ doses, effective doses, and risk indices from 13 representative adult CT protocols using four types of reference phantoms (XCAT, ICRP 110, ImPACT, and CT-Expo). Despite closely-matched organ mass, total body weight, and height, large differences in organ dose exist due to variation in organ location, spatial distribution, and dose approximation method. Dose differences for fully irradiated radiosensitive organs were much smaller than those for partially irradiated organs. Weighted dosimetry quantities including effective dose, male risk indices, k factors, and male q factors agreed well across phantoms. The female risk indices and q factors varied considerably across phantoms.
Item Open Access Image noise and dose performance across a clinical population: patient size adaptation as a metric of CT performance.(Med Phys, 2017-02-24) Ria, Francesco; Wilson, Joshua Mark; Zhang, Yakun; Samei, EhsanPURPOSE: Modern CT systems adjust x-ray flux accommodating for patient size to achieve certain image noise values. The effectiveness of this adaptation is an important aspect of CT performance and should ideally be characterized in the context of real patient cases. The objective of this study was to characterize CT performance with a new metric that includes image noise and radiation dose across a clinical patient population. MATERIALS AND METHODS: The study included 1526 examinations performed by three CT scanners (one GE Healthcare Discovery CT750HD, one GE Healthcare Lightspeed VCT, and one Siemens SOMATOM definition Flash) used for two routine clinical protocols (abdominopelvic with contrast and chest without contrast). An institutional monitoring system recorded all the data involved in the study. The dose-patient size and noise-patient size dependencies were linearized by considering a first order approximation of analytical models that describe the relationship between ionization dose and patient size, as well as image noise and patient size. A 3D-fit was performed for each protocol and each scanner with a planar function, and the Root Mean Square Error (RMSE) values were estimated as a metric of CT adaptability across the patient population. RESULTS: The data show different scanner dependencies in terms of adaptability: the RMSE values for the three scanners are between 0.0385 HU(1/2) and 0.0215 HU(1/2) . CONCLUSIONS: A theoretical relationship between image noise, CTDIvol and patient size was determined based on real patient data. This relationship may be interpreted as a new metric related to the scanners' adaptability concerning image quality and radiation dose across a patient population. This method could be implemented to investigate the adaptability related to other image quality indexes and radiation dose in a clinical population. This article is protected by copyright. All rights reserved.Item Open Access Organ doses from CT localizer radiographs: Development, validation, and application of a Monte Carlo estimation technique(MEDICAL PHYSICS, 2019-11-01) Hoye, Jocelyn; Sharma, Shobhit; Zhang, Yakun; Fu, Wanyi; Ria, Francesco; Kapadia, Anuj; Segars, W Paul; Wilson, Joshua; Samei, EhsanItem Open Access Organ Doses from CT Localizer Radiographs: Development, Validation, and Application of a Monte Carlo Estimation Technique.(Medical physics, 2019-08-23) Hoye, Jocelyn; Sharma, Shobhit; Zhang, Yakun; Fu, Wanyi; Ria, Francesco; Kapadia, Anuj; Segars, W Paul; Wilson, Joshua; Samei, EhsanPURPOSE:The purpose of this study was to simulate and validate organ doses from different CT localizer radiograph geometries using Monte Carlo methods for a population of patients. METHODS:A Monte Carlo method was developed to estimate organ doses from CT localizer radiographs using PENELOPE. The method was validated by comparing dosimetry estimates with measurements using an anthropomorphic phantom imbedded with thermoluminescent dosimeters (TLDs) scanned on a commercial CT system (Siemens SOMATOM Flash). The Monte Carlo simulation platform was then applied to conduct a population study with fifty-seven adult computational phantoms (XCAT). In the population study, clinically relevant chest localizer protocols were simulated with the x-ray tube in anterior-posterior (AP), right lateral, and PA positions. Mean organ doses and associated standard deviations (in mGy) were then estimated for all simulations. The obtained organ doses were studied as a function of patient chest diameter. Organ doses for breast and lung were compared across different views and represented as a percentage of organ doses from rotational CT scans. RESULTS:The validation study showed an agreement between the Monte Carlo and physical TLD measurements with a maximum percent difference of 15.5% and a mean difference of 3.5% across all organs. The XCAT population study showed that breast dose from AP localizers was the highest with a mean value of 0.24 mGy across patients, while the lung dose was relatively consistent across different localizer geometries. The organ dose estimates were found to vary across the patient population, partially explained by the changes in the patient chest diameter. The average effective dose was 0.18 mGy for AP, 0.09 mGy for lateral, and 0.08 mGy for PA localizer. CONCLUSION:A platform to estimate organ doses in CT localizer scans using Monte Carlo methods was implemented and validated based on comparison with physical dose measurements. The simulation platform was applied to a virtual patient population, where the localizer organ doses were found to range within 0.4-8.6% of corresponding organ doses for a typical CT scan, 0.2-3.3% of organ doses for a CT pulmonary angiography scan, and 1.1-20.8% of organ doses for a low dose lung cancer screening scan.