Browsing by Subject "AIDS Serodiagnosis"
Now showing 1 - 2 of 2
Results Per Page
Sort Options
Item Open Access Comparison of Detection Limits of Fourth- and Fifth-Generation Combination HIV Antigen-Antibody, p24 Antigen, and Viral Load Assays on Diverse HIV Isolates.(Journal of clinical microbiology, 2018-08) Stone, Mars; Bainbridge, John; Sanchez, Ana M; Keating, Sheila M; Pappas, Andrea; Rountree, Wes; Todd, Chris; Bakkour, Sonia; Manak, Mark; Peel, Sheila A; Coombs, Robert W; Ramos, Eric M; Shriver, M Kathleen; Contestable, Paul; Nair, Sangeetha Vijaysri; Wilson, David H; Stengelin, Martin; Murphy, Gary; Hewlett, Indira; Denny, Thomas N; Busch, Michael PDetection of acute HIV infection is critical for HIV public health and diagnostics. Clinical fourth-generation antigen (Ag)/antibody (Ab) combination (combo) and p24 Ag immunoassays have enhanced detection of acute infection compared to Ab-alone assays but require ongoing evaluation with currently circulating diverse subtypes. Genetically and geographically diverse HIV clinical isolates were used to assess clinical HIV diagnostic, blood screening, and next-generation assays. Three-hundred-member panels of 20 serially diluted well-characterized antibody-negative HIV isolates for which the researchers were blind to the results (blind panels) were distributed to manufacturers and end-user labs to assess the relative analytic sensitivity of currently approved and preapproved clinical HIV fourth-generation Ag/Ab combo or p24 Ag-alone immunoassays for the detection of diverse subtypes. The limits of detection (LODs) of virus were estimated for different subtypes relative to confirmed viral loads. Analysis of immunoassay sensitivity was benchmarked against confirmed viral load measurements on the blind panel. On the basis of the proportion of positive results on 300 observations, all Ag/Ab combo and standard sensitivity p24 Ag assays performed similarly and within half-log LODs, illustrating the similar breadth of reactivity and diagnostic utility. Ultrasensitive p24 Ag assays achieved dramatically increased sensitivities, while the rapid combo assays performed poorly. The similar performance of the different commercially available fourth-generation assays on diverse subtypes supports their use in broad geographic settings with locally circulating HIV clades and recombinant strains. Next-generation preclinical ultrasensitive p24 Ag assays achieved dramatically improved sensitivity, while rapid fourth-generation assays performed poorly for p24 Ag detection.Item Open Access The association of HIV counseling and testing with HIV risk behaviors in a random population-based survey in Kisumu, Kenya.(AIDS Behav, 2011-05) Huchko, Megan J; Montandon, Michele; Nguti, Rosemary; Bukusi, Elizabeth A; Cohen, Craig RHIV testing has been promoted as a key HIV prevention strategy in low-resource settings, despite studies showing variable impact on risk behavior. We sought to examine rates of HIV testing and the association between testing and sexual risk behaviors in Kisumu, Kenya. Participants were interviewed about HIV testing and sexual risk behaviors. They then underwent HIV serologic testing. We found that 47% of women and 36% of men reported prior testing. Two-thirds of participants who tested HIV-positive in this study reported no prior HIV test. Women who had undergone recent testing were less likely to report high-risk behaviors than women who had never been tested; this was not seen among men. Although rates of HIV testing were higher than seen in previous studies, the majority of HIV-infected people were unaware of their status. Efforts should be made to increase HIV testing among this population.