Browsing by Subject "Bone Nails"
Now showing 1 - 4 of 4
- Results Per Page
- Sort Options
Item Open Access Cost utility analysis of intramedullary nailing and skeletal traction treatment for patients with femoral shaft fractures in Malawi.(Acta orthopaedica, 2021-08) Chokotho, Linda; Donnelley, Claire A; Young, Sven; Lau, Brian C; Wu, Hao-Hua; Mkandawire, Nyengo; Gjertsen, Jan-Erik; Hallan, Geir; Agarwal-Harding, Kiran J; Shearer, DavidBackground and purpose - In Malawi, both skeletal traction (ST) and intramedullary nailing (IMN) are used in the treatment of femoral shaft fractures, ST being the mainstay treatment. Previous studies have found that IMN has improved outcomes and is less expensive than ST. However, no cost-effectiveness analyses have yet compared IMN and ST in Malawi. We report the results of a cost-utility analysis (CUA) comparing treatment using either IMN or ST.Patients and methods - This was an economic evaluation study, where a CUA was done using a decision-tree model from the government healthcare payer and societal perspectives with an 1-year time horizon. We obtained EQ-5D-3L utility scores and probabilities from a prospective observational study assessing quality of life and function in 187 adult patients with femoral shaft fractures treated with either IMN or ST. The patients were followed up at 6 weeks, and 3, 6, and 12 months post-injury. Quality adjusted life years (QALYs) were calculated from utility scores using the area under the curve method. Direct treatment costs were obtained from a prospective micro costing study. Indirect costs included patient lost productivity, patient transportation, meals, and childcare costs associated with hospital stay and follow-up visits. Multiple sensitivity analyses assessed model uncertainty.Results - Total treatment costs were higher for ST ($1,349) compared with IMN ($1,122). QALYs were lower for ST than IMN, 0.71 (95% confidence interval [CI] 0.66-0.76) and 0.77 (CI 0.71-0.82) respectively. Based on lower cost and higher utility, IMN was the dominant strategy. IMN remained dominant in 94% of simulations. IMN would be less cost-effective than ST at a total procedure cost exceeding $880 from the payer's perspective, or $1,035 from the societal perspective.Interpretation - IMN was cost saving and more effective than ST in the treatment of adult femoral shaft fractures in Malawi, and may be an efficient use of limited healthcare resources.Item Open Access Evaluation of monoenergetic imaging to reduce metallic instrumentation artifacts in computed tomography of the cervical spine.(Journal of neurosurgery. Spine, 2015-01) Komlosi, Peter; Grady, Deborah; Smith, Justin S; Shaffrey, Christopher I; Goode, Allen R; Judy, Patricia G; Shaffrey, Mark; Wintermark, MaxObject
Monoenergetic imaging with dual-energy CT has been proposed to reduce metallic artifacts in comparison with conventional polychromatic CT. The purpose of this study is to systematically evaluate and define the optimal dual-energy CT imaging parameters for specific cervical spinal implant alloy compositions.Methods
Spinal fixation rods of cobalt-chromium or titanium alloy inserted into the cervical spine section of an Alderson Rando anthropomorphic phantom were imaged ex vivo with fast-kilovoltage switching CT at 80 and 140 peak kV. The collimation width and field of view were varied between 20 and 40 mm and medium to large, respectively. Extrapolated monoenergetic images were generated at 70, 90, 110, and 130 kiloelectron volts (keV). The standard deviation of voxel intensities along a circular line profile around the spine was used as an index of the magnitude of metallic artifact.Results
The metallic artifact was more conspicuous around the fixation rods made of cobalt-chromium than those of titanium alloy. The magnitude of metallic artifact seen with titanium fixation rods was minimized at monoenergies of 90 keV and higher, using a collimation width of 20 mm and large field of view. The magnitude of metallic artifact with cobalt-chromium fixation rods was minimized at monoenergies of 110 keV and higher; collimation width or field of view had no effect.Conclusions
Optimization of acquisition settings used with monoenergetic CT studies might yield reduced metallic artifacts.Item Open Access Femoral malrotation after intramedullary nailing in obese versus non-obese patients.(Injury, 2014-07) Koerner, John D; Patel, Neeraj M; Yoon, Richard S; Gage, Mark J; Donegan, Derek J; Liporace, Frank AOBJECTIVE: Intramedullary nailing (IMN) of obese patients with femoral fractures can be difficult due to soft tissue considerations and overall body habitus. Complications including malrotation can occur and have significant impact on postoperative function. The purpose of this study was to evaluate femoral rotation after intramedullary nailing of obese and non-obese patients to see if there was a difference in rotation, complications and any risk factors for malrotation. MATERIALS AND METHODS: Between 2000 and 2009, 417 consecutive patients with femur fractures treated with IM nail at Level I trauma and tertiary referral center. Of these, 335 with postoperative computed tomography (CT) scanogram of the bilateral lower extremities were included in this study. Baseline demographic, perioperative and postoperative femoral version calculations were included in the dataset. Statistical analysis included chi-squared test for categorical data, t-test for continuous data, and univariate and multivariate regression analysis. Significance was set at p<0.05. RESULTS: Of the 417 patients with femur fractures between 2000 and 2009, 335 met criteria for this study. There were 111 patients with a BMI <25, 129 with BMI 25-29.9, and 95 patients with a BMI >30. When BMI was categorised into 3 groups (<25, 25-29.9, or 30+), none of these groups were predictive of version in univariate or multivariate regressions. Among only obese patients (BMI 30+), BMI of 35+ was not a significant predictor of version when compared to BMI 30-34.9. There were no significant differences in femoral version based on entry point (antegrade vs. retrograde) in any BMI category. There were also no significant difference between groups of patients with a DFV of >15̊ (p=0.212). CONCLUSIONS: Based on this study, BMI did not have an effect on postoperative difference in femoral version. In fact, in our multivariate regression analysis, BMI of over 30 was actually predictive of significantly lower difference in femoral version. While other studies have documented the intraoperative difficulties encountered with obese patients with femur fractures, the outcome of femoral rotation is not affected by an increasing BMI.Item Open Access Prospective multicenter assessment of risk factors for rod fracture following surgery for adult spinal deformity.(Journal of neurosurgery. Spine, 2014-12) Smith, Justin S; Shaffrey, Ellen; Klineberg, Eric; Shaffrey, Christopher I; Lafage, Virginie; Schwab, Frank J; Protopsaltis, Themistocles; Scheer, Justin K; Mundis, Gregory M; Fu, Kai-Ming G; Gupta, Munish C; Hostin, Richard; Deviren, Vedat; Kebaish, Khaled; Hart, Robert; Burton, Douglas C; Line, Breton; Bess, Shay; Ames, Christopher P; International Spine Study GroupObject
Improved understanding of rod fracture (RF) following adult spinal deformity (ASD) surgery could prove valuable for surgical planning, patient counseling, and implant design. The objective of this study was to prospectively assess the rates of and risk factors for RF following surgery for ASD.Methods
This was a prospective, multicenter, consecutive series. Inclusion criteria were ASD, age > 18 years, ≥5 levels posterior instrumented fusion, baseline full-length standing spine radiographs, and either development of RF or full-length standing spine radiographs obtained at least 1 year after surgery that demonstrated lack of RF. ASD was defined as presence of at least one of the following: coronal Cobb angle ≥20°, sagittal vertical axis (SVA) ≥5 cm, pelvic tilt (PT) ≥25°, and thoracic kyphosis ≥60°.Results
Of 287 patients who otherwise met inclusion criteria, 200 (70%) either demonstrated RF or had radiographic imaging obtained at a minimum of 1 year after surgery showing lack of RF. The patients' mean age was 54.8 ± 15.8 years; 81% were women; 10% were smokers; the mean body mass index (BMI) was 27.1 ± 6.5; the mean number of levels fused was 12.0 ± 3.8; and 50 patients (25%) had a pedicle subtraction osteotomy (PSO). The rod material was cobalt chromium (CC) in 53%, stainless steel (SS), in 26%, or titanium alloy (TA) in 21% of cases; the rod diameters were 5.5 mm (in 68% of cases), 6.0 mm (in 13%), or 6.35 mm (in 19%). RF occurred in 18 cases (9.0%) at a mean of 14.7 months (range 3-27 months); patients without RF had a mean follow-up of 19 months (range 12-24 months). Patients with RF were older (62.3 vs 54.1 years, p = 0.036), had greater BMI (30.6 vs 26.7, p = 0.019), had greater baseline sagittal malalignment (SVA 11.8 vs 5.0 cm, p = 0.001; PT 29.1° vs 21.9°, p = 0.016; and pelvic incidence [PI]-lumbar lordosis [LL] mismatch 29.6° vs 12.0°, p = 0.002), and had greater sagittal alignment correction following surgery (SVA reduction by 9.6 vs 2.8 cm, p < 0.001; and PI-LL mismatch reduction by 26.3° vs 10.9°, p = 0.003). RF occurred in 22.0% of patients with PSO (10 of the 11 fractures occurred adjacent to the PSO level), with rates ranging from 10.0% to 31.6% across centers. CC rods were used in 68% of PSO cases, including all with RF. Smoking, levels fused, and rod diameter did not differ significantly between patients with and without RF (p > 0.05). In cases including a PSO, the rate of RF was significantly higher with CC rods than with TA or SS rods (33% vs 0%, p = 0.010). On multivariate analysis, only PSO was associated with RF (p = 0.001, OR 5.76, 95% CI 2.01-15.8).Conclusions
Rod fracture occurred in 9.0% of ASD patients and in 22.0% of PSO patients with a minimum of 1-year follow-up. With further follow-up these rates would likely be even higher. There was a substantial range in the rate of RF with PSO across centers, suggesting potential variations in technique that warrant future investigation. Due to higher rates of RF with PSO, alternative instrumentation strategies should be considered for these cases.