Browsing by Subject "Computed Tomography Angiography"
Now showing 1 - 2 of 2
Results Per Page
Sort Options
Item Open Access Anomalous Origin of the Right Coronary Artery from the Pulmonary Artery in a Neonate with Turner Syndrome and Aortic Arch Hypoplasia.(Texas Heart Institute journal, 2019-06) Stefek, Bryan P; Imundo, Jason R; Clark, Joseph BAnomalous origin of the right coronary artery from the pulmonary artery, a rare congenital cardiac defect, is typically not diagnosed during infancy. On the other hand, Turner syndrome is usually diagnosed early, and it is classically associated with bicuspid aortic valve and aortic coarctation. Individuals with Turner syndrome are also at increased risk for coronary artery anomalies. We present a case of anomalous right coronary artery from the pulmonary artery in a week-old neonate who also had Turner syndrome, patent ductus arteriosus, transverse aortic arch hypoplasia, and impaired ventricular function. Prostaglandin therapy through the ductus increased the patient's myocardial perfusion. Four months after corrective surgery, she was doing well. We discuss the reperfusion phenomenon in our patient's case, as well as other considerations in this combination of congenital defects.Item Open Access Utility of virtual monoenergetic images derived from a dual-layer detector-based spectral CT in the assessment of aortic anatomy and pathology: A retrospective case control study.(Clinical imaging, 2018-11) Chalian, Hamid; Kalisz, Kevin; Rassouli, Negin; Dhanantwari, Amar; Rajiah, PrabhakarOBJECTIVES:To evaluate the ability of the retrospectively generated virtual monoenergetic images (VMIs) from a dual-layer detector-based spectral computed tomography (SDCT) to augment aortic enhancement for the evaluation of aortic anatomy and pathology. METHODS:98 patients with suboptimal aortic enhancement (≤200 HU) were retrospectively identified from SDCT scans. VMI from 40 to 80 keV were generated. Attenuation, noise, SNR, and CNR were measured at seven levels in the aorta. Image quality was graded on a 5-point scale, 5 being the best. From the VMI, an ideal set was chosen with mean vascular attenuation above 200 HU while maintaining diagnostic quality. Image parameters and quality of this ideal-set were compared to the standard 120-kVp images. RESULTS:The mean attenuation of all seven measured anatomical regions was 156.6 ± 61.7 HU in the 120-kVp images. Attenuation of the VMI from 40 to 70 keV were higher than the 120-kVp image, measuring 439.2 ± 215.3 HU, 298.5 ± 140.6 HU, 213.4 ± 94.3 HU, and 164.7 ± 90.2 HU, for 40 keV, 50 keV, 60 keV, and 70 keV, respectively (p value <0.01 for 40, 50, 60 keV; 0.07 for 70 keV). SNR and CNR showed similar trends. The 50 keV VMI had the best image quality (4.48 ± 0.84 vs. 2.24 ± 0.92 on 120-kVp images, p < 0.001). Attenuation, CNR, and SNR increased by 90.6%, 85.0%, and 108.1% at 50 keV compared to 120-kVp. CONCLUSIONS:A contrast-enhanced CT study can be optimized for the assessment of the aorta by using low-energy VMI obtained using SDCT. At the optimal monoenergetic level, attenuation, SNR, CNR and image quality were significantly higher than that of conventional polyenergetic images.