Browsing by Subject "D-dimer"
Now showing 1 - 2 of 2
Results Per Page
Sort Options
Item Open Access Elevated D-Dimer Is Associated with Multiple Clinical Outcomes in Hospitalized Covid-19 Patients: a Retrospective Cohort Study.(SN comprehensive clinical medicine, 2020-11-08) Wagner, Jason; Garcia-Rodriguez, Victor; Yu, Abraham; Dutra, Barbara; DuPont, Andrew; Cash, Brooks; Farooq, AhmadD-dimer is a prognostic marker for Covid-19 disease mortality and severity in hospitalized patients; however, little is known about the association between D-dimer and other clinical outcomes. The aim of this paper was to define a threshold of D-dimer to use in hospitalized patients with Covid-19 and to assess its utility in prognosticating in-hospital mortality, development of an acute kidney injury (AKI), and need for hemodialysis, vasopressors, or intubation. This is a single-center, retrospective, cohort review study of 100 predominantly minority patients (94%) hospitalized with Covid-19. The electronic medical record system was used to collect data. Receiver operating characteristics (ROC) and area under the curve (AUC) analysis were used to determine optimal thresholds of peak D-dimer, defined as the highest D-dimer obtained during admission that was clinically meaningful. Odds ratios were then used to assess the relationship between peak D-dimer thresholds and clinical outcomes. D-dimer > 2.1 μg/mL and > 2.48 μg/mL had > 90% sensitivity and > 50% specificity for predicting need for vasopressors (AUC 0.80) or intubation (AUC 0.83) and in-hospital mortality (AUC 0.89), respectively. Additionally, D-dimer > 4.86 μg/mL had a 100% sensitivity and 81% specificity for predicting the need for hemodialysis (AUC 0.92). Furthermore, peak D-dimer > 2.48 μg/mL was associated with in-hospital mortality (p < 0.001), development of an AKI (p = 0.002), and need for intubation (p < 0.001), hemodialysis (p < 0.001), and vasopressors (p < 0.001). Peak D-dimer > 2.48 μg/mL may be a useful threshold that is prognostic of multiple clinical outcomes in hospitalized patients with Covid-19.Item Open Access International, multicenter evaluation of a new D-dimer assay for the exclusion of venous thromboembolism using standard and age-adjusted cut-offs.(Thrombosis research, 2018-04-05) Parry, Blair Alden; Chang, Anna Marie; Schellong, Sebastian M; House, Stacey L; Fermann, Gregory J; Deadmon, Erin K; Giordano, Nicholas J; Chang, Yuchiao; Cohen, Jason; Robak, Nancy; Singer, Adam J; Mulrow, Mary; Reibling, Ellen T; Francis, Samuel; Griffin, S Michelle; Prochaska, Jürgen H; Davis, Barbara; McNelis, Patricia; Delgado, Joao; Kümpers, Philipp; Werner, Nikos; Gentile, Nina T; Zeserson, Eli; Wild, Philipp S; Limkakeng, Alexander T; Walters, Elizabeth Lea; LoVecchio, Frank; Theodoro, Daniel; Hollander, Judd E; Kabrhel, ChristopherWe sought to determine the test characteristics of an automated INNOVANCE D-dimer assay for the exclusion of pulmonary embolism (PE) and deep venous thrombosis (DVT) in emergency department (ED) patients using standard and age-adjusted cut-offs.Cross-sectional, international, multicenter study of consecutive patients with suspected DVT or PE in 24 centers (18 USA, 6 Europe). Evaluated patients had low or intermediate Wells PE or DVT scores. For the standard cut-off, a D-dimer result <500 ng/ml was negative. For the age adjusted cut-off, we used the formula: Age (years) ∗ 10. The diagnostic standard was imaging demonstrating PE or DVT within 3 months. We calculated test characteristics using standard methods. We also explored modifications of the age adjustment multiplier.We included 3837 patients and excluded 251. The mean age of patients evaluated for PE (n = 1834) was 48 ± 16 years, with 676 (37%) male, and 1081 (59%) white. The mean age of evaluated for DVT (n = 1752) was 53 ± 16 years, with 710 (41%) male, and 1172 (67%) white. D-dimer test characteristics for PE were: sensitivity 98.0%, specificity 55.4%, negative predictive value (NPV) 99.8%, positive predictive value (PPV) 11.4%, and for DVT were: sensitivity 92.0%, specificity 44.8%, NPV 98.8%, PPV 10.3%. Age adjustment increased specificity (59.6% [PE], 51.1% [DVT]), but increasing the age-adjustment multiplier decreased sensitivity without increasing specificity.INNOVANCE D-dimer is highly sensitive and can exclude PE and DVT in ED patients with low- and intermediate- pre-test probability. Age-adjustment increases specificity, without increasing false negatives.