Browsing by Subject "Dose-Response Relationship, Radiation"
Now showing 1 - 6 of 6
Results Per Page
Sort Options
Item Open Access Early hematopoiesis inhibition under chronic radiation exposure in humans.(Radiat Environ Biophys, 2010-05) Akleyev, Alexander V; Akushevich, Igor V; Dimov, Georgy P; Veremeyeva, Galina A; Varfolomeyeva, Tatyana A; Ukraintseva, Svetlana V; Yashin, Anatoly IThe major goal of this study was to identify and quantitatively describe the association between the characteristics of chronic (low-dose rate) exposure to (low LET) ionizing radiation and cellularity of peripheral blood cell lines. About 3,200 hemograms (i.e., spectra of blood counts) obtained over the years of maximal exposure to ionizing radiation (1950-1956) for inhabitants of the Techa River were used in analyses. The mean cumulative red bone marrow dose (with standard errors), calculated using Techa River Dosimetry System-2000, was 333.6 +/- 4.6 mGy (SD = 259.9 mGy, max = 1151 mGy) to the year 1956. The statistical approach included both empirical methods for estimating frequencies of cytopenic states of the investigated blood cell lines (e.g. neutrophile, platelets, erythrocyte, etc.), and regression methods, including generalized linear models and logistic regressions which allowed taking into account confounding factors (e.g., attained age, age at maximal exposure, presence of concomitant diseases, and demographic characteristics). The results of the analyses demonstrated hematopoiesis inhibition manifested by a decrease in peripheral blood cellularity and an increase in the frequency of cytopenia in all blood cell lines (leukocytes, including lymphocytes, monocytes, neutrophiles, as well as platelets and erythrocytes). The intensity of hematopoiesis inhibition in the period of maximal exposures is determined by the combined influence of the dose rate and cumulative dose. The contribution of specific confounding factors was quantified and shown to be much less important than dose characteristics. The best predictor among dose characteristics was identified for each blood cell line. A 2-fold increase in dose rate is assumed to be a characteristic of radiosensitivity and a quantitative characteristic of the effect.Item Open Access Gene expression signatures that predict radiation exposure in mice and humans.(PLoS Med, 2007-04) Dressman, Holly K; Muramoto, Garrett G; Chao, Nelson J; Meadows, Sarah; Marshall, Dawn; Ginsburg, Geoffrey S; Nevins, Joseph R; Chute, John PBACKGROUND: The capacity to assess environmental inputs to biological phenotypes is limited by methods that can accurately and quantitatively measure these contributions. One such example can be seen in the context of exposure to ionizing radiation. METHODS AND FINDINGS: We have made use of gene expression analysis of peripheral blood (PB) mononuclear cells to develop expression profiles that accurately reflect prior radiation exposure. We demonstrate that expression profiles can be developed that not only predict radiation exposure in mice but also distinguish the level of radiation exposure, ranging from 50 cGy to 1,000 cGy. Likewise, a molecular signature of radiation response developed solely from irradiated human patient samples can predict and distinguish irradiated human PB samples from nonirradiated samples with an accuracy of 90%, sensitivity of 85%, and specificity of 94%. We further demonstrate that a radiation profile developed in the mouse can correctly distinguish PB samples from irradiated and nonirradiated human patients with an accuracy of 77%, sensitivity of 82%, and specificity of 75%. Taken together, these data demonstrate that molecular profiles can be generated that are highly predictive of different levels of radiation exposure in mice and humans. CONCLUSIONS: We suggest that this approach, with additional refinement, could provide a method to assess the effects of various environmental inputs into biological phenotypes as well as providing a more practical application of a rapid molecular screening test for the diagnosis of radiation exposure.Item Open Access Impact of collimator leaf width and treatment technique on stereotactic radiosurgery and radiotherapy plans for intra- and extracranial lesions.(Radiation oncology (London, England), 2009-01-21) Wu, Q Jackie; Wang, Zhiheng; Kirkpatrick, John P; Chang, Zheng; Meyer, Jeffrey J; Lu, Mei; Huntzinger, Calvin; Yin, Fang-FangBACKGROUND: This study evaluated the dosimetric impact of various treatment techniques as well as collimator leaf width (2.5 vs 5 mm) for three groups of tumors -- spine tumors, brain tumors abutting the brainstem, and liver tumors. These lesions often present challenges in maximizing dose to target volumes without exceeding critical organ tolerance. Specifically, this study evaluated the dosimetric benefits of various techniques and collimator leaf sizes as a function of lesion size and shape. METHODS: Fifteen cases (5 for each site) were studied retrospectively. All lesions either abutted or were an integral part of critical structures (brainstem, liver or spinal cord). For brain and liver lesions, treatment plans using a 3D-conformal static technique (3D), dynamic conformal arcs (DARC) or intensity modulation (IMRT) were designed with a conventional linear accelerator with standard 5 mm leaf width multi-leaf collimator, and a linear accelerator dedicated for radiosurgery and hypofractionated therapy with a 2.5 mm leaf width collimator. For the concave spine lesions, intensity modulation was required to provide adequate conformality; hence, only IMRT plans were evaluated using either the standard or small leaf-width collimators.A total of 70 treatment plans were generated and each plan was individually optimized according to the technique employed. The Generalized Estimating Equation (GEE) was used to separate the impact of treatment technique from the MLC system on plan outcome, and t-tests were performed to evaluate statistical differences in target coverage and organ sparing between plans. RESULTS: The lesions ranged in size from 2.6 to 12.5 cc, 17.5 to 153 cc, and 20.9 to 87.7 cc for the brain, liver, and spine groups, respectively. As a group, brain lesions were smaller than spine and liver lesions. While brain and liver lesions were primarily ellipsoidal, spine lesions were more complex in shape, as they were all concave. Therefore, the brain and the liver groups were compared for volume effect, and the liver and spine groups were compared for shape. For the brain and liver groups, both the radiosurgery MLC and the IMRT technique contributed to the dose sparing of organs-at-risk(OARs), as dose in the high-dose regions of these OARs was reduced up to 15%, compared to the non-IMRT techniques employing a 5 mm leaf-width collimator. Also, the dose reduction contributed by the fine leaf-width MLC decreased, as dose savings at all levels diminished from 4 - 11% for the brain group to 1 - 5% for the liver group, as the target structures decreased in volume. The fine leaf-width collimator significantly improved spinal cord sparing, with dose reductions of 14 - 19% in high to middle dose regions, compared to the 5 mm leaf width collimator. CONCLUSION: The fine leaf-width MLC in combination with the IMRT technique can yield dosimetric benefits in radiosurgery and hypofractionated radiotherapy. Treatment of small lesions in cases involving complex target/OAR geometry will especially benefit from use of a fine leaf-width MLC and the use of IMRT.Item Open Access Modeling hematopoietic system response caused by chronic exposure to ionizing radiation.(Radiat Environ Biophys, 2011-05) Akushevich, Igor V; Veremeyeva, Galina A; Dimov, Georgy P; Ukraintseva, Svetlana V; Arbeev, Konstantin G; Akleyev, Alexander V; Yashin, Anatoly IA new model of the hematopoietic system response in humans chronically exposed to ionizing radiation describes the dynamics of the hematopoietic stem cell compartment as well as the dynamics of each of the four blood cell types (lymphocytes, neutrophiles, erythrocytes, and platelets). The required model parameters were estimated based on available results of human and experimental animal studies. They include the steady-state number of hematopoietic stem cells and peripheral blood cell lines in an unexposed organism, amplification parameters for each blood line, parameters describing proliferation and apoptosis, parameters of feedback functions regulating the steady-state numbers, and characteristics of radiosensitivity related to cell death and non-lethal cell damage. The model predictions were tested using data on hematological measurements (e.g., blood counts) performed in 1950-1956 in the Techa River residents chronically exposed to ionizing radiation since 1949. The suggested model of hematopoiesis is capable of describing experimental findings in the Techa River Cohort, including: (1) slopes of the dose-effect curves reflecting the inhibition of hematopoiesis due to chronic ionizing radiation, (2) delay in effect of chronic exposure and accumulated character of the effect, and (3) dose-rate patterns for different cytopenic states (e.g., leukopenia, thrombocytopenia).Item Open Access Novel Manganese-Porphyrin Superoxide Dismutase-Mimetic Widens the Therapeutic Margin in a Preclinical Head and Neck Cancer Model.(International journal of radiation oncology, biology, physics, 2015-11) Ashcraft, Kathleen A; Boss, Mary-Keara; Tovmasyan, Artak; Roy Choudhury, Kingshuk; Fontanella, Andrew N; Young, Kenneth H; Palmer, Gregory M; Birer, Samuel R; Landon, Chelsea D; Park, Won; Das, Shiva K; Weitner, Tin; Sheng, Huaxin; Warner, David S; Brizel, David M; Spasojevic, Ivan; Batinic-Haberle, Ines; Dewhirst, Mark WPurpose
To test the effects of a novel Mn porphyrin oxidative stress modifier, Mn(III) meso-tetrakis(N-n-butoxyethylpyridinium-2-yl)porphyrin (MnBuOE), for its radioprotective and radiosensitizing properties in normal tissue versus tumor, respectively.Methods and materials
Murine oral mucosa and salivary glands were treated with a range of radiation doses with or without MnBuOE to establish the dose-effect curves for mucositis and xerostomia. Radiation injury was quantified by intravital near-infrared imaging of cathepsin activity, assessment of salivation, and histologic analysis. To evaluate effects of MnBuOE on the tumor radiation response, we administered the drug as an adjuvant to fractionated radiation of FaDu xenografts. Again, a range of radiation therapy (RT) doses was administered to establish the radiation dose-effect curve. The 50% tumor control dose values with or without MnBuOE and dose-modifying factor were determined.Results
MnBuOE protected normal tissue by reducing RT-mediated mucositis, xerostomia, and fibrosis. The dose-modifying factor for protection against xerostomia was 0.77. In contrast, MnBuOE increased tumor local control rates compared with controls. The dose-modifying factor, based on the ratio of 50% tumor control dose values, was 1.3. Immunohistochemistry showed that MnBuOE-treated tumors exhibited a significant influx of M1 tumor-associated macrophages, which provides mechanistic insight into its radiosensitizing effects in tumors.Conclusions
MnBuOE widens the therapeutic margin by decreasing the dose of radiation required to control tumor, while increasing normal tissue resistance to RT-mediated injury. This is the first study to quantitatively demonstrate the magnitude of a single drug's ability to radioprotect normal tissue while radiosensitizing tumor.Item Open Access Optical-CT 3D Dosimetry Using Fresnel Lenses with Minimal Refractive-Index Matching Fluid.(PLoS One, 2016) Bache, Steven; Malcolm, Javian; Adamovics, John; Oldham, MarkTelecentric optical computed tomography (optical-CT) is a state-of-the-art method for visualizing and quantifying 3-dimensional dose distributions in radiochromic dosimeters. In this work a prototype telecentric system (DFOS-Duke Fresnel Optical-CT Scanner) is evaluated which incorporates two substantial design changes: the use of Fresnel lenses (reducing lens costs from $10-30K t0 $1-3K) and the use of a 'solid tank' (which reduces noise, and the volume of refractively matched fluid from 1 ltr to 10 cc). The efficacy of DFOS was evaluated by direct comparison against commissioned scanners in our lab. Measured dose distributions from all systems were compared against the predicted dose distributions from a commissioned treatment planning system (TPS). Three treatment plans were investigated including a simple four-field box treatment, a multiple small field delivery, and a complex IMRT treatment. Dosimeters were imaged within 2 h post irradiation, using consistent scanning techniques (360 projections acquired at 1 degree intervals, reconstruction at 2mm). DFOS efficacy was evaluated through inspection of dose line-profiles, and 2D and 3D dose and gamma maps. DFOS/TPS gamma pass rates with 3%/3mm dose difference/distance-to-agreement criteria ranged from 89.3% to 92.2%, compared to from 95.6% to 99.0% obtained with the commissioned system. The 3D gamma pass rate between the commissioned system and DFOS was 98.2%. The typical noise rates in DFOS reconstructions were up to 3%, compared to under 2% for the commissioned system. In conclusion, while the introduction of a solid tank proved advantageous with regards to cost and convenience, further work is required to improve the image quality and dose reconstruction accuracy of the new DFOS optical-CT system.