Item Open Access Distant Harrington rod migration 35 years after implantation.(Journal of clinical neuroscience : official journal of the Neurosurgical Society of Australasia, 2013-10) Lark, Robert K; Caputo, Adam M; Brown, Christopher R; Michael, Keith W; Thacker, Julie K; Richardson, William JHarrington rods have been successfully implanted in thousands of patients for the correction of scoliotic deformity since the 1950s. An exceedingly rare complication of Harrington rod placement is loosening with resultant migration. The authors present a 50-year-old woman who had a single Harrington rod placed when she was 15 years old. Thirty-five years later, she presented with acute sensory changes in her lower extremities. Imaging revealed rod failure and migration of the hardware distally, resulting in penetration of the wall of the rectum. Due to the unique anatomical position of the migrated hardware, sigmoidoscopy was used to directly visualize and remove the rod. The patient ultimately made a full recovery. Rod migration is an exceedingly rare complication that has been described only a few times since the introduction of Harrington rods over 60 years ago. The case herein is particularly unique given the extensive period of time that passed before migration (35 years) and the use of sigmoidoscopy for hardware removal.Item Open Access Embolization of patent foramen ovale closure devices: incidence, role of imaging in identification, potential causes, and management.(Tex Heart Inst J, 2013) Goel, Sachin S; Aksoy, Olcay; Tuzcu, E Murat; Krasuski, Richard A; Kapadia, Samir RTranscatheter patent foramen ovale (PFO) closure is an alternative to antiplatelet or anticoagulative therapy in patients with cryptogenic stroke, and it is associated with a small incidence of periprocedural sequelae. Because embolization of PFO closure devices is a very rare procedural complication, data on its frequency, causes, and management are sparse. We sought to review the medical literature and the cases of PFO closure-device embolization at our institution with the aim of identifying likely problems and reporting potential solutions. Out of 310 adult patients who underwent transcatheter PFO closure from June 2002 through April 2011, there were 2 cases (0.6%) of PFO closure-device embolization. In both patients, hypermobile septum primum and thick septum secundum were present. In one patient, failure to use a sizing balloon might have resulted in an underestimation of the PFO's size. In both patients, device embolization was identified in a timely fashion, the embolized device was safely retrieved, and the PFO was percutaneously closed with success. The incidence of PFO closure-device embolization is very low. The cases described here underscore the importance of imaging in the identification of morphologic predispositions to closure-device malpositioning, in the recognition of impending embolization, and in the timely management of embolization.Item Open Access Optimal management of Riata leads with no known electrical abnormalities or externalization: a decision analysis.(Journal of cardiovascular electrophysiology, 2015-02) Pokorney, Sean D; Zhou, Ke; Matchar, David B; Love, Sean; Zeitler, Emily P; Lewis, Robert; Piccini, Jonathan PIntroduction
Riata and Riata ST implantable cardioverter-defibrillator (ICD) leads (St. Jude Medical, Sylmar, CA, USA) can develop conductor cable externalization and/or electrical failure. Optimal management of these leads remains unknown.Methods and results
A Markov model compared 4 lead management strategies: (1) routine device interrogation for electrical failure, (2) systematic yearly fluoroscopic screening and routine device interrogation, (3) implantation of new ICD lead with capping of the in situ lead, and (4) implantation of new ICD lead with extraction of the in situ lead. The base case was a 64-year-old primary prevention ICD patient. Modeling demonstrated average life expectancies as follows: capping with new lead implanted at 134.5 months, extraction with new lead implanted at 134.0 months, fluoroscopy with routine interrogation at 133.9 months, and routine interrogation at 133.5 months. One-way sensitivity analyses identified capping as the preferred strategy with only one parameter having a threshold value: when risk of nonarrhythmic death associated with lead abandonment is greater than 0.05% per year, lead extraction is preferred over capping. A second-order Monte Carlo simulation (n = 10,000), as a probabilistic sensitivity analysis, found that lead revision was favored with 100% certainty (extraction 76% and capping 24%).Conclusions
Overall there were minimal differences in survival with monitoring versus active lead management approaches. There is no evidence to support fluoroscopic screening for externalization of Riata or Riata ST leads.