Browsing by Subject "Optical Phenomena"
Now showing 1 - 3 of 3
Results Per Page
Sort Options
Item Open Access A low-cost, portable, and quantitative spectral imaging system for application to biological tissues.(Opt Express, 2010-06-07) Fu, Henry L; Yu, Bing; Lo, Justin Y; Palmer, Greg M; Kuech, Thomas F; Ramanujam, NimmiThe ability of diffuse reflectance spectroscopy to extract quantitative biological composition of tissues has been used to discern tissue types in both pre-clinical and clinical cancer studies. Typically, diffuse reflectance spectroscopy systems are designed for single-point measurements. Clinically, an imaging system would provide valuable spatial information on tissue composition. While it is feasible to build a multiplexed fiber-optic probe based spectral imaging system, these systems suffer from drawbacks with respect to cost and size. To address these we developed a compact and low cost system using a broadband light source with an 8-slot filter wheel for illumination and silicon photodiodes for detection. The spectral imaging system was tested on a set of tissue mimicking liquid phantoms which yielded an optical property extraction accuracy of 6.40 +/- 7.78% for the absorption coefficient (micro(a)) and 11.37 +/- 19.62% for the wavelength-averaged reduced scattering coefficient (micro(s)').Item Open Access Control of the orientational order and nonlinear optical response of the "push-pull" chromophore RuPZn via specific incorporation into densely packed monolayer ensembles of an amphiphilic four-helix bundle peptide: characterization of the peptide-chromophore complexes.(J Am Chem Soc, 2010-08-18) Krishnan, Venkata; Tronin, Andrey; Strzalka, Joseph; Fry, H Christopher; Therien, Michael J; Blasie, J Kent"Push-pull" chromophores based on extended pi-electron systems have been designed to exhibit exceptionally large molecular hyperpolarizabilities. We have engineered an amphiphilic four-helix bundle peptide to vectorially incorporate such hyperpolarizable chromophores having a metalloporphyrin moiety, with high specificity into the interior core of the bundle. The amphiphilic exterior of the bundle facilitates the formation of densely packed monolayer ensembles of the vectorially oriented peptide-chromophore complexes at the liquid-gas interface. Chemical specificity designed into the ends of the bundle facilitates the subsequent covalent attachment of these monolayer ensembles onto the surface of an inorganic substrate. In this article, we describe the structural characterization of these monolayer ensembles at each stage of their fabrication for one such peptide-chromophore complex designated as AP0-RuPZn. In the accompanying article, we describe the characterization of their macroscopic nonlinear optical properties.Item Open Access Identification of fluorescent beads using a coded aperture snapshot spectral imager.(Appl Opt, 2010-04-01) Cull, Christy Fernandez; Choi, Kerkil; Brady, David J; Oliver, TimWe apply a coded aperture snapshot spectral imager (CASSI) to fluorescence microscopy. CASSI records a two-dimensional (2D) spectrally filtered projection of a three-dimensional (3D) spectral data cube. We minimize a convex quadratic function with total variation (TV) constraints for data cube estimation from the 2D snapshot. We adapt the TV minimization algorithm for direct fluorescent bead identification from CASSI measurements by combining a priori knowledge of the spectra associated with each bead type. Our proposed method creates a 2D bead identity image. Simulated fluorescence CASSI measurements are used to evaluate the behavior of the algorithm. We also record real CASSI measurements of a ten bead type fluorescence scene and create a 2D bead identity map. A baseline image from filtered-array imaging system verifies CASSI's 2D bead identity map.