Browsing by Subject "Radiotherapy Planning, Computer-Assisted"
Now showing 1 - 20 of 21
- Results Per Page
- Sort Options
Item Open Access A Collimator Setting Optimization Algorithm for Dual-Arc Volumetric Modulated Arc Therapy in Pancreas Stereotactic Body Radiation Therapy.(Technology in cancer research & treatment, 2019-01) Li, Xinyi; Wu, Jackie; Palta, Manisha; Zhang, You; Sheng, Yang; Zhang, Jiahan; Wang, ChunhaoPURPOSE:To optimize collimator setting to improve dosimetric quality of pancreas volumetric modulated arc therapy plan for stereotactic body radiation therapy. MATERIALS AND METHODS:Fifty-five volumetric modulated arc therapy cases in stereotactic body radiation therapy of pancreas were retrospectively included in this study with internal review board approval. Different from the routine practice of initializing collimator settings with a template, the proposed algorithm simultaneously optimizes the collimator angles and jaw positions that are customized to the patient geometry. Specifically, this algorithm includes 2 key steps: (1) an iterative optimization algorithm via simulated annealing that generates a set of potential collimator settings from 39 cases with pancreas stereotactic body radiation therapy, and (2) a multi-leaf collimator modulation scoring system that makes the final decision of the optimal collimator settings (collimator angles and jaw positions) based on organs at risk sparing criteria. For validation, the other 16 cases with pancreas stereotactic body radiation therapy were analyzed. Two plans were generated for each validation case, with one plan optimized using the proposed algorithm (Planopt) and the other plan with the template setting (Planconv). Each plan was optimized with 2 full arcs and the same set of constraints for the same case. Dosimetric results were analyzed and compared, including target dose coverage, conformity, organs at risk maximum dose, and modulation complexity score. All results were tested by Wilcoxon signed rank tests, and the statistical significance level was set to .05. RESULTS:Both plan groups had comparable target dose coverage and mean doses of all organs at risk. However, organs at risk (stomach, duodenum, large/small bowel) maximum dose sparing (D0.1 cc and D0.03 cc) was improved in Planopt compared to Planconv. Planopt also showed lower modulation complexity score, which suggests better capability of handling complex shape and sparing organs at risk . CONCLUSIONS:The proposed collimator settings optimization algorithm successfully improved dosimetric performance for dual-arc pancreas volumetric modulated arc therapy plans in stereotactic body radiation therapy of pancreas. This algorithm has the capability of immediate clinical application.Item Open Access A positioning QA procedure for 2D/2D (kV/MV) and 3D/3D (CT/CBCT) image matching for radiotherapy patient setup.(Journal of applied clinical medical physics, 2009-10-06) Guan, Huaiqun; Hammoud, Rabih; Yin, Fang-FangA positioning QA procedure for Varian's 2D/2D (kV/MV) and 3D/3D (planCT/CBCT) matching was developed. The procedure was to check: (1) the coincidence of on-board imager (OBI), portal imager (PI), and cone beam CT (CBCT)'s isocenters (digital graticules) to a linac's isocenter (to a pre-specified accuracy); (2) that the positioning difference detected by 2D/2D (kV/MV) and 3D/3D(planCT/CBCT) matching can be reliably transferred to couch motion. A cube phantom with a 2 mm metal ball (bb) at the center was used. The bb was used to define the isocenter. Two additional bbs were placed on two phantom surfaces in order to define a spatial location of 1.5 cm anterior, 1.5 cm inferior, and 1.5 cm right from the isocenter. An axial scan of the phantom was acquired from a multislice CT simulator. The phantom was set at the linac's isocenter (lasers); either AP MV/R Lat kV images or CBCT images were taken for 2D/2D or 3D/3D matching, respectively. For 2D/2D, the accuracy of each device's isocenter was obtained by checking the distance between the central bb and the digital graticule. Then the central bb in orthogonal DRRs was manually moved to overlay to the off-axis bbs in kV/MV images. For 3D/3D, CBCT was first matched to planCT to check the isocenter difference between the two CTs. Manual shifts were then made by moving CBCT such that the point defined by the two off-axis bbs overlay to the central bb in planCT. (PlanCT can not be moved in the current version of OBI1.4.) The manual shifts were then applied to remotely move the couch. The room laser was used to check the accuracy of the couch movement. For Trilogy (or Ix-21) linacs, the coincidence of imager and linac's isocenter was better than 1 mm (or 1.5 mm). The couch shift accuracy was better than 2 mm.Item Open Access Adaptive stereotactic body radiation therapy planning for lung cancer.(Int J Radiat Oncol Biol Phys, 2013-09-01) Qin, Y; Zhang, F; Yoo, DS; Kelsey, CR; Yin, FF; Cai, JPURPOSE: To investigate the dosimetric effects of adaptive planning on lung stereotactic body radiation therapy (SBRT). METHODS AND MATERIALS: Forty of 66 consecutive lung SBRT patients were selected for a retrospective adaptive planning study. CBCT images acquired at each fraction were used for treatment planning. Adaptive plans were created using the same planning parameters as the original CT-based plan, with the goal to achieve comparable comformality index (CI). For each patient, 2 cumulative plans, nonadaptive plan (PNON) and adaptive plan (PADP), were generated and compared for the following organs-at-risks (OARs): cord, esophagus, chest wall, and the lungs. Dosimetric comparison was performed between PNON and PADP for all 40 patients. Correlations were evaluated between changes in dosimetric metrics induced by adaptive planning and potential impacting factors, including tumor-to-OAR distances (dT-OAR), initial internal target volume (ITV1), ITV change (ΔITV), and effective ITV diameter change (ΔdITV). RESULTS: 34 (85%) patients showed ITV decrease and 6 (15%) patients showed ITV increase throughout the course of lung SBRT. Percentage ITV change ranged from -59.6% to 13.0%, with a mean (±SD) of -21.0% (±21.4%). On average of all patients, PADP resulted in significantly (P=0 to .045) lower values for all dosimetric metrics. ΔdITV/dT-OAR was found to correlate with changes in dose to 5 cc (ΔD5cc) of esophagus (r=0.61) and dose to 30 cc (ΔD30cc) of chest wall (r=0.81). Stronger correlations between ΔdITV/dT-OAR and ΔD30cc of chest wall were discovered for peripheral (r=0.81) and central (r=0.84) tumors, respectively. CONCLUSIONS: Dosimetric effects of adaptive lung SBRT planning depend upon target volume changes and tumor-to-OAR distances. Adaptive lung SBRT can potentially reduce dose to adjacent OARs if patients present large tumor volume shrinkage during the treatment.Item Open Access American Association of Physicists in Medicine Task Group 263: Standardizing Nomenclatures in Radiation Oncology.(International journal of radiation oncology, biology, physics, 2018-03) Mayo, Charles S; Moran, Jean M; Bosch, Walter; Xiao, Ying; McNutt, Todd; Popple, Richard; Michalski, Jeff; Feng, Mary; Marks, Lawrence B; Fuller, Clifton D; Yorke, Ellen; Palta, Jatinder; Gabriel, Peter E; Molineu, Andrea; Matuszak, Martha M; Covington, Elizabeth; Masi, Kathryn; Richardson, Susan L; Ritter, Timothy; Morgas, Tomasz; Flampouri, Stella; Santanam, Lakshmi; Moore, Joseph A; Purdie, Thomas G; Miller, Robert C; Hurkmans, Coen; Adams, Judy; Jackie Wu, Qing-Rong; Fox, Colleen J; Siochi, Ramon Alfredo; Brown, Norman L; Verbakel, Wilko; Archambault, Yves; Chmura, Steven J; Dekker, Andre L; Eagle, Don G; Fitzgerald, Thomas J; Hong, Theodore; Kapoor, Rishabh; Lansing, Beth; Jolly, Shruti; Napolitano, Mary E; Percy, James; Rose, Mark S; Siddiqui, Salim; Schadt, Christof; Simon, William E; Straube, William L; St James, Sara T; Ulin, Kenneth; Yom, Sue S; Yock, Torunn IA substantial barrier to the single- and multi-institutional aggregation of data to supporting clinical trials, practice quality improvement efforts, and development of big data analytics resource systems is the lack of standardized nomenclatures for expressing dosimetric data. To address this issue, the American Association of Physicists in Medicine (AAPM) Task Group 263 was charged with providing nomenclature guidelines and values in radiation oncology for use in clinical trials, data-pooling initiatives, population-based studies, and routine clinical care by standardizing: (1) structure names across image processing and treatment planning system platforms; (2) nomenclature for dosimetric data (eg, dose-volume histogram [DVH]-based metrics); (3) templates for clinical trial groups and users of an initial subset of software platforms to facilitate adoption of the standards; (4) formalism for nomenclature schema, which can accommodate the addition of other structures defined in the future. A multisociety, multidisciplinary, multinational group of 57 members representing stake holders ranging from large academic centers to community clinics and vendors was assembled, including physicists, physicians, dosimetrists, and vendors. The stakeholder groups represented in the membership included the AAPM, American Society for Radiation Oncology (ASTRO), NRG Oncology, European Society for Radiation Oncology (ESTRO), Radiation Therapy Oncology Group (RTOG), Children's Oncology Group (COG), Integrating Healthcare Enterprise in Radiation Oncology (IHE-RO), and Digital Imaging and Communications in Medicine working group (DICOM WG); A nomenclature system for target and organ at risk volumes and DVH nomenclature was developed and piloted to demonstrate viability across a range of clinics and within the framework of clinical trials. The final report was approved by AAPM in October 2017. The approval process included review by 8 AAPM committees, with additional review by ASTRO, European Society for Radiation Oncology (ESTRO), and American Association of Medical Dosimetrists (AAMD). This Executive Summary of the report highlights the key recommendations for clinical practice, research, and trials.Item Open Access Delivery efficiency of an Elekta linac under gated operation.(Journal of applied clinical medical physics, 2014-09-08) Cui, Guoqiang; Housley, David J; Chen, Fan; Mehta, Vivek K; Shepard, David MIn this study, we have characterized the efficiency of an Elekta linac in the delivery of gated radiotherapy. We have explored techniques to reduce the beam-on delay and to improve the delivery efficiency, and have investigated the impact of frequent beam interruptions on the dosimetric accuracy of gated deliveries. A newly available gating interface was installed on an Elekta Synergy. Gating signals were generated using a surface mapping system in conjunction with a respiratory motion phantom. A series of gated deliveries were performed using volumetric modulated arc therapy (VMAT) treatment plans previously generated for lung cancer patients treated with stereotactic body radiotherapy. Baseline values were determined for the delivery times. The machine was then tuned in an effort to minimize beam-on delays and improve delivery efficiency. After that process was completed, the dosimetric accuracy of the gated deliveries was evaluated by comparing the measured and the planned coronal dose distributions using gamma index analyses. Comparison of the gated and the non-gated deliveries were also performed. The results demonstrated that, with the optimal machine settings, the average beam-on delay was reduced to less than 0.22 s. High dosimetric accuracy was demonstrated with gamma index passing rates no lower than 99.0% for all tests (3%/3 mm criteria). Consequently, Elekta linacs can provide a practical solution for gated VMAT treatments with high dosimetric accuracy and only a moderate increase in the overall delivery time.Item Open Access Development of a neuro-fuzzy technique for automated parameter optimization of inverse treatment planning.(Radiation oncology (London, England), 2009-01) Stieler, Florian; Yan, Hui; Lohr, Frank; Wenz, Frederik; Yin, Fang-FangBACKGROUND: Parameter optimization in the process of inverse treatment planning for intensity modulated radiation therapy (IMRT) is mainly conducted by human planners in order to create a plan with the desired dose distribution. To automate this tedious process, an artificial intelligence (AI) guided system was developed and examined. METHODS: The AI system can automatically accomplish the optimization process based on prior knowledge operated by several fuzzy inference systems (FIS). Prior knowledge, which was collected from human planners during their routine trial-and-error process of inverse planning, has first to be "translated" to a set of "if-then rules" for driving the FISs. To minimize subjective error which could be costly during this knowledge acquisition process, it is necessary to find a quantitative method to automatically accomplish this task. A well-developed machine learning technique, based on an adaptive neuro fuzzy inference system (ANFIS), was introduced in this study. Based on this approach, prior knowledge of a fuzzy inference system can be quickly collected from observation data (clinically used constraints). The learning capability and the accuracy of such a system were analyzed by generating multiple FIS from data collected from an AI system with known settings and rules. RESULTS: Multiple analyses showed good agreements of FIS and ANFIS according to rules (error of the output values of ANFIS based on the training data from FIS of 7.77 +/- 0.02%) and membership functions (3.9%), thus suggesting that the "behavior" of an FIS can be propagated to another, based on this process. The initial experimental results on a clinical case showed that ANFIS is an effective way to build FIS from practical data, and analysis of ANFIS and FIS with clinical cases showed good planning results provided by ANFIS. OAR volumes encompassed by characteristic percentages of isodoses were reduced by a mean of between 0 and 28%. CONCLUSION: The study demonstrated a feasible way to automatically perform parameter optimization of inverse treatment planning under guidance of prior knowledge without human intervention other than providing a set of constraints that have proven clinically useful in a given setting.Item Open Access Diode-based transmission detector for IMRT delivery monitoring: a validation study.(Journal of applied clinical medical physics, 2016-09-08) Li, Taoran; Wu, Q Jackie; Matzen, Thomas; Yin, Fang-Fang; O'Daniel, Jennifer CThe purpose of this work was to evaluate the potential of a new transmission detector for real-time quality assurance of dynamic-MLC-based radiotherapy. The accuracy of detecting dose variation and static/dynamic MLC position deviations was measured, as well as the impact of the device on the radiation field (surface dose, transmission). Measured dose variations agreed with the known variations within 0.3%. The measurement of static and dynamic MLC position deviations matched the known deviations with high accuracy (0.7-1.2 mm). The absorption of the device was minimal (~ 1%). The increased surface dose was small (1%-9%) but, when added to existing collimator scatter effects could become significant at large field sizes (≥ 30 × 30 cm2). Overall the accuracy and speed of the device show good potential for real-time quality assurance.Item Open Access Dosimetric assessment of rigid setup error by CBCT for HN-IMRT.(Journal of applied clinical medical physics, 2010-05-28) Worthy, Danielle; Wu, QiuwenDose distributions in HN-IMRT are complex and may be sensitive to the treatment uncertainties. The goals of this study were to evaluate: 1) dose differences between plan and actual delivery and implications on margin requirement for HN-IMRT with rigid setup errors; 2) dose distribution complexity on setup error sensitivity; and 3) agreement between average dose and cumulative dose in fractionated radiotherapy. Rigid setup errors for HN-IMRT patients were measured using cone-beam CT (CBCT) for 30 patients and 896 fractions. These were applied to plans for 12HN patients who underwent simultaneous integrated boost (SIB) IMRT treatment. Dose distributions were recalculated at each fraction and summed into cumulative dose. Measured setup errors were scaled by factors of 2-4 to investigate margin adequacy. Two plans, direct machine parameter optimization (DMPO) and fluence only (FO), were available for each patient to represent plans of different complexity. Normalized dosimetric indices, conformity index (CI) and conformation number (CN) were used in the evaluation. It was found that current 5 mm margins are more than adequate to compensate for rigid setup errors, and that standard margin recipes overestimate margins for rigid setup error in SIB HN-IMRT because of differences in acceptance criteria used in margin evaluation. The CTV-to-PTV margins can be effectively reduced to 1.9 mm and 1.5 mm for CTV1 and CTV2. Plans of higher complexity and sharper dose gradients are more sensitive to setup error and require larger margins. The CI and CN are not recommended for cumulative dose evaluation because of inconsistent definition of target volumes used. For fractionated radiotherapy in HN-IMRT, the average fractional dose does not represent the true cumulative dose received by the patient through voxel-by-voxel summation, primarily due to the setup error characteristics, where the random component is larger than systematic and different target regions get underdosed at each fraction.Item Open Access Effect of machine learning methods on predicting NSCLC overall survival time based on Radiomics analysis.(Radiation oncology (London, England), 2018-10-05) Sun, Wenzheng; Jiang, Mingyan; Dang, Jun; Chang, Panchun; Yin, Fang-FangBACKGROUND:To investigate the effect of machine learning methods on predicting the Overall Survival (OS) for non-small cell lung cancer based on radiomics features analysis. METHODS:A total of 339 radiomic features were extracted from the segmented tumor volumes of pretreatment computed tomography (CT) images. These radiomic features quantify the tumor phenotypic characteristics on the medical images using tumor shape and size, the intensity statistics and the textures. The performance of 5 feature selection methods and 8 machine learning methods were investigated for OS prediction. The predicted performance was evaluated with concordance index between predicted and true OS for the non-small cell lung cancer patients. The survival curves were evaluated by the Kaplan-Meier algorithm and compared by the log-rank tests. RESULTS:The gradient boosting linear models based on Cox's partial likelihood method using the concordance index feature selection method obtained the best performance (Concordance Index: 0.68, 95% Confidence Interval: 0.62~ 0.74). CONCLUSIONS:The preliminary results demonstrated that certain machine learning and radiomics analysis method could predict OS of non-small cell lung cancer accuracy.Item Open Access Evaluation of an electron Monte Carlo dose calculation algorithm for electron beam.(Journal of applied clinical medical physics, 2008-06-23) Hu, Ye Angela; Song, Haijun; Chen, Zhe; Zhou, Sumin; Yin, Fang-FangThe electron Monte Carlo (eMC) dose calculation algorithm of the Eclipse treatment planning system is based heavily upon Monte Carlo simulation of the linac head and modeling of the linac beam characteristics with minimal measurement of beam data. Commissioning of the eMC algorithm on multiple identical linacs provided a unique opportunity to systematically evaluate the algorithm with actual measurements of clinically relevant beam and dose parameters. In this study, measured and eMC calculated dose distributions were compared both along and perpendicular to electron beam direction for electron energy/applicator/depth combination using measurement data from four Varian 21EX CLINAC linear accelerator (Varian Medical System, Palo Alto, CA). Cutout factors for sizes down to 3 x 3 cm were also compared. Comparisons between the measurement and the eMC calculated values show that the R90, R80, R50, and R10 values mostly agree within 3 mm. Measure and Calculated bremsstrahlung dose Dx correlates well statistically although eMC calculated Dx values are consistently smaller than the measured, with maximum discrepancy of 1% for the 20 MeV electron beams. Surface dose agrees mostly within 2%. Field width and penumbra agree mostly within 3mm. Calculation grid size is found to have a significant effect on the dose calculation. A grid size of 5 mm can produce erroneous dose distributions. Using a grid size of 2.5 mm and a 3% accuracy specified for the eMC to stop calculation iteration, the absolute output agrees with measurements within 3% for field sizes of 5 x 5 cm or larger. For cutout of 3 x 3 cm, however, the output disagreement can reach 8%. Our result indicate that eMC algorithm in Eclipse provides acceptable agreement with measurement data for most clinical situations. Calculation grid size of 2.5 mm or smaller is recommended.Item Open Access Evaluation of dosimetric uncertainty caused by MR geometric distortion in MRI-based liver SBRT treatment planning.(Journal of applied clinical medical physics, 2019-02) Han, Silu; Yin, Fang-Fang; Cai, JingPURPOSE:MRI-based treatment planning is a promising technique for liver stereotactic-body radiation therapy (SBRT) treatment planning to improve target volume delineation and reduce radiation dose to normal tissues. MR geometric distortion, however, is a source of potential error in MRI-based treatment planning. The aim of this study is to investigate dosimetric uncertainties caused by MRI geometric distortion in MRI-based treatment planning for liver SBRT. MATERIALS AND METHODS:The study was conducted using computer simulations. 3D MR geometric distortion was simulated using measured data in the literature. Planning MR images with distortions were generated by integrating the simulated 3D MR geometric distortion onto planning CT images. MRI-based treatment plans were then generated on the planning MR images with two dose calculation methods: (1) using original CT numbers; and (2) using organ-specific assigned CT numbers. Dosimetric uncertainties of various dose-volume-histogram parameters were determined as their differences between the simulated MRI-based plans and the original clinical CT-based plans for five liver SBRT cases. RESULTS:The average simulated distortion for the five liver SBRT cases was 2.77 mm. In the case of using original CT numbers for dose calculation, the average dose uncertainties for target volumes and critical structures were <0.5 Gy, and the average target volume percentage at prescription dose uncertainties was 0.97%. In the case of using assigned CT numbers, the average dose uncertainties for target volumes and critical structures were <1.0 Gy, and the average target volume percentage at prescription dose uncertainties was 2.02%. CONCLUSIONS:Dosimetric uncertainties caused by MR geometric distortion in MRI-based liver SBRT treatment planning was generally small (<1 Gy) when the distortion is 3 mm.Item Open Access Imaging system QA of a medical accelerator, Novalis Tx, for IGRT per TG 142: our 1 year experience.(Journal of applied clinical medical physics, 2012-07-05) Chang, Z; Bowsher, J; Cai, J; Yoo, S; Wang, Z; Adamson, J; Ren, L; Yin, FFAmerican Association of Physicists in Medicine (AAPM) task group (TG) 142 has recently published a report to update recommendations of the AAPM TG 40 report and add new recommendations concerning medical accelerators in the era of image-guided radiation therapy (IGRT). The recommendations of AAPM TG 142 on IGRT are timely. In our institute, we established a comprehensive imaging QA program on a medical accelerator based on AAPM TG 142 and implemented it successfully. In this paper, we share our one-year experience and performance evaluation of an OBI capable linear accelerator, Novalis Tx, per TG 142 guidelines.Item Open Access Impact of collimator leaf width and treatment technique on stereotactic radiosurgery and radiotherapy plans for intra- and extracranial lesions.(Radiation oncology (London, England), 2009-01-21) Wu, Q Jackie; Wang, Zhiheng; Kirkpatrick, John P; Chang, Zheng; Meyer, Jeffrey J; Lu, Mei; Huntzinger, Calvin; Yin, Fang-FangBACKGROUND: This study evaluated the dosimetric impact of various treatment techniques as well as collimator leaf width (2.5 vs 5 mm) for three groups of tumors -- spine tumors, brain tumors abutting the brainstem, and liver tumors. These lesions often present challenges in maximizing dose to target volumes without exceeding critical organ tolerance. Specifically, this study evaluated the dosimetric benefits of various techniques and collimator leaf sizes as a function of lesion size and shape. METHODS: Fifteen cases (5 for each site) were studied retrospectively. All lesions either abutted or were an integral part of critical structures (brainstem, liver or spinal cord). For brain and liver lesions, treatment plans using a 3D-conformal static technique (3D), dynamic conformal arcs (DARC) or intensity modulation (IMRT) were designed with a conventional linear accelerator with standard 5 mm leaf width multi-leaf collimator, and a linear accelerator dedicated for radiosurgery and hypofractionated therapy with a 2.5 mm leaf width collimator. For the concave spine lesions, intensity modulation was required to provide adequate conformality; hence, only IMRT plans were evaluated using either the standard or small leaf-width collimators.A total of 70 treatment plans were generated and each plan was individually optimized according to the technique employed. The Generalized Estimating Equation (GEE) was used to separate the impact of treatment technique from the MLC system on plan outcome, and t-tests were performed to evaluate statistical differences in target coverage and organ sparing between plans. RESULTS: The lesions ranged in size from 2.6 to 12.5 cc, 17.5 to 153 cc, and 20.9 to 87.7 cc for the brain, liver, and spine groups, respectively. As a group, brain lesions were smaller than spine and liver lesions. While brain and liver lesions were primarily ellipsoidal, spine lesions were more complex in shape, as they were all concave. Therefore, the brain and the liver groups were compared for volume effect, and the liver and spine groups were compared for shape. For the brain and liver groups, both the radiosurgery MLC and the IMRT technique contributed to the dose sparing of organs-at-risk(OARs), as dose in the high-dose regions of these OARs was reduced up to 15%, compared to the non-IMRT techniques employing a 5 mm leaf-width collimator. Also, the dose reduction contributed by the fine leaf-width MLC decreased, as dose savings at all levels diminished from 4 - 11% for the brain group to 1 - 5% for the liver group, as the target structures decreased in volume. The fine leaf-width collimator significantly improved spinal cord sparing, with dose reductions of 14 - 19% in high to middle dose regions, compared to the 5 mm leaf width collimator. CONCLUSION: The fine leaf-width MLC in combination with the IMRT technique can yield dosimetric benefits in radiosurgery and hypofractionated radiotherapy. Treatment of small lesions in cases involving complex target/OAR geometry will especially benefit from use of a fine leaf-width MLC and the use of IMRT.Item Open Access Knowledge-based IMRT treatment planning for prostate cancer.(2011) Chanyavanich, VorakarnThe goal of intensity-modulated radiation therapy (IMRT) treatment plan optimization is to produce a cumulative dose distribution that satisfies both the dose prescription and the normal tissue dose constraints. The typical manual treatment planning process is iterative, time consuming, and highly dependent on the skill and experience of the planner. We have addressed this problem by developing a knowledge based approach that utilizes a database of prior plans to leverage the planning expertise of physicians and physicists at our institution. We developed a case-similarity algorithm that uses mutual information to identify a similar matched case for a given query case, and various treatment parameters from the matched case are then adapted to derive new treatment plans that are patient specific. We used 10 randomly selected cases matched against a knowledge base of 100 cases to demonstrate that new, clinically acceptable IMRT treatment plans can be developed. This approach substantially reduced planning time by skipping all but the last few iterations of the optimization process. Additionally, we established a simple metric based on the areas under the curve (AUC) of the dose volume histogram (DVH), specifically for the planning target volume (PTV), rectum, and bladder. This plan quality metric was used to successfully rank order the plan quality of a collection of knowledgebased plans. Further, we used 100 pre-optimized plans (20 query x 5 matches) to show that the average normalized MI score can be used as a surrogate of overall plan quality. Plans of lower pre-optimized plan quality tended to improve substantially after optimization, though its final plan quality did not improve to the same level as a plan that has a higher pre-optimized plan quality to begin with. Optimization usually improved PTV coverage slightly while providing substantial dose sparing for both bladder and rectum of 12.4% and 9.1% respectively. Lastly, we developed new treatment plans for cases selected from an outside institution matched against our sitespecific database. The knowledge-based plans are very comparable to the original manual plan, providing adequate PTV coverage as well as substantial improvement in dose sparing to the rectum and bladder. In conclusion, we found that a site-specific database of prior plans can be effectively used to design new treatment plans for our own institution as well as outside cases. Specifically, knowledge-based plans can provide clinically acceptable planning target volume coverage and clinically acceptable dose sparing to the rectum and bladder. This approach has been demonstrated to improve the efficiency of the treatment planning process, and may potentially improve the quality of patient care by enabling more consistent treatment planning across institutions.Item Open Access On the sensitivity of TG-119 and IROC credentialing to TPS commissioning errors.(Journal of applied clinical medical physics, 2016-01-08) McVicker, Drew; Yin, Fang-Fang; Adamson, Justus DWe investigate the sensitivity of IMRT commissioning using the TG-119 C-shape phantom and credentialing with the IROC head and neck phantom to treatment planning system commissioning errors. We introduced errors into the various aspects of the commissioning process for a 6X photon energy modeled using the analytical anisotropic algorithm within a commercial treatment planning system. Errors were implemented into the various components of the dose calculation algorithm including primary photons, secondary photons, electron contamination, and MLC parameters. For each error we evaluated the probability that it could be committed unknowingly during the dose algorithm commissioning stage, and the probability of it being identified during the verification stage. The clinical impact of each commissioning error was evaluated using representative IMRT plans including low and intermediate risk prostate, head and neck, mesothelioma, and scalp; the sensitivity of the TG-119 and IROC phantoms was evaluated by comparing dosimetric changes to the dose planes where film measurements occur and change in point doses where dosimeter measurements occur. No commissioning errors were found to have both a low probability of detection and high clinical severity. When errors do occur, the IROC credentialing and TG 119 commissioning criteria are generally effective at detecting them; however, for the IROC phantom, OAR point-dose measurements are the most sensitive despite being currently excluded from IROC analysis. Point-dose measurements with an absolute dose constraint were the most effective at detecting errors, while film analysis using a gamma comparison and the IROC film distance to agreement criteria were less effective at detecting the specific commissioning errors implemented here.Item Open Access Quantitative comparison of automatic and manual IMRT optimization for prostate cancer: the benefits of DVH prediction.(Journal of applied clinical medical physics, 2015-03-08) Yang, Yun; Li, Taoran; Yuan, Lunlin; Ge, Yaorong; Yin, Fang-Fang; Lee, W Robert; Wu, Q JackieA recent publication indicated that the patient anatomical feature (PAF) model was capable of predicting optimal objectives based on past experience. In this study, the benefits of IMRT optimization using PAF-predicted objectives as guidance for prostate were evaluated. Three different optimization methods were compared.1) Expert Plan: Ten prostate cases (16 plans) were planned by an expert planner using conventional trial-and-error approach started with institutional modified OAR and PTV constraints. Optimization was stopped at 150 iterations and that plan was saved as Expert Plan. 2) Clinical Plan: The planner would keep working on the Expert Plan till he was satisfied with the dosimetric quality and the final plan was referred to as Clinical Plan. 3) PAF Plan: A third sets of plans for the same ten patients were generated fully automatically using predicted DVHs as guidance. The optimization was based on PAF-based predicted objectives, and was continued to 150 iterations without human interaction. DMAX and D98% for PTV, DMAX for femoral heads, DMAX, D10cc, D25%/D17%, and D40% for bladder/rectum were compared. Clinical Plans are further optimized with more iterations and adjustments, but in general provided limited dosimetric benefits over Expert Plans. PTV D98% agreed within 2.31% among Expert, Clinical, and PAF plans. Between Clinical and PAF Plans, differences for DMAX of PTV, bladder, and rectum were within 2.65%, 2.46%, and 2.20%, respectively. Bladder D10cc was higher for PAF but < 1.54% in general. Bladder D25% and D40% were lower for PAF, by up to 7.71% and 6.81%, respectively. Rectum D10cc, D17%, and D40% were 2.11%, 2.72%, and 0.27% lower for PAF, respectively. DMAX for femoral heads were comparable (< 35 Gy on average). Compared to Clinical Plan (Primary + Boost), the average optimization time for PAF plan was reduced by 5.2 min on average, with a maximum reduction of 7.1min. Total numbers of MUs per plan for PAF Plans were lower than Clinical Plans, indicating better delivery efficiency. The PAF-guided planning process is capable of generating clinical-quality prostate IMRT plans with no human intervention. Compared to manual optimization, this automatic optimization increases planning and delivery efficiency, while maintainingplan quality.Item Open Access Task Group 174 Report: Utilization of [18 F]Fluorodeoxyglucose Positron Emission Tomography ([18 F]FDG-PET) in Radiation Therapy.(Medical physics, 2019-10) Das, Shiva K; McGurk, Ross; Miften, Moyed; Mutic, Sasa; Bowsher, James; Bayouth, John; Erdi, Yusuf; Mawlawi, Osama; Boellaard, Ronald; Bowen, Stephen R; Xing, Lei; Bradley, Jeffrey; Schoder, Heiko; Yin, Fang-Fang; Sullivan, Daniel C; Kinahan, PaulThe use of positron emission tomography (PET) in radiation therapy (RT) is rapidly increasing in the areas of staging, segmentation, treatment planning, and response assessment. The most common radiotracer is 18 F-fluorodeoxyglucose ([18 F]FDG), a glucose analog with demonstrated efficacy in cancer diagnosis and staging. However, diagnosis and RT planning are different endeavors with unique requirements, and very little literature is available for guiding physicists and clinicians in the utilization of [18 F]FDG-PET in RT. The two goals of this report are to educate and provide recommendations. The report provides background and education on current PET imaging systems, PET tracers, intensity quantification, and current utilization in RT (staging, segmentation, image registration, treatment planning, and therapy response assessment). Recommendations are provided on acceptance testing, annual and monthly quality assurance, scanning protocols to ensure consistency between interpatient scans and intrapatient longitudinal scans, reporting of patient and scan parameters in literature, requirements for incorporation of [18 F]FDG-PET in treatment planning systems, and image registration. The recommendations provided here are minimum requirements and are not meant to cover all aspects of the use of [18 F]FDG-PET for RT.Item Open Access The application of distance transformation on parameter optimization of inverse planning in intensity-modulated radiation therapy.(Journal of applied clinical medical physics, 2008-04-16) Yan, Hui; Yin, Fang-FangIn inverse planning for intensity-modulated radiation therapy (IMRT), the dose specification and related weighting factor of an objective function for involved organs is usually predefined by a single value and then iteratively optimized, subject to a set of dose-volume constraints. Because the actual dose distribution is essentially non-uniform and considerably affected by the geometric shape and distribution of the anatomic structures involved, the spatial information regarding those structures should be incorporated such that the predefined parameter distribution is made to approach the clinically expected distribution. Ideally, these parameter distributions should be predefined on a voxel basis in a manual method. However, such an approach is too time-consuming to be feasible in routine use. In the present study, we developed a computer-aided method to achieve the goal described above, producing a non-uniform parameter distribution based on spatial information about the anatomic structures involved. The method consists of two steps: Use distance transformation technique to calculate the distance distribution of the structures. Based on the distance distribution, produce the parameter distribution via a function guided by prior knowledge. We use two simulated cases to examine the effectiveness of the method. The results indicate that application of a non-uniform parameter distribution produced by distance transformation clearly improves dose-sparing of critical organs without compromising dose coverage of the planning target.Item Open Access The investigation on the location effect of external markers in respiratory-gated radiotherapy.(Journal of applied clinical medical physics, 2008-04-16) Yan, Hui; Zhu, Guopei; Yang, James; Lu, Mei; Ajlouni, Munther; Kim, Jae Ho; Yin, Fang-FangPURPOSE:To investigate the effect of the marker placement on the correlation relationship between the motions of external markers and the internal target under different breathing patterns for several lung cancer patients. METHOD AND MATERIAL:To monitor and record simultaneous motions of internal target and associated surrogate markers during respiratory gated radiotherapy, an infrared camera system synchronized with a medical simulator was installed in our institute. Multiple external markers were placed on the patients' chest wall with proper geometrical arrangement in closely monitoring the motion of skin near tumor. The motion signals of three breathing sessions (free breathing, breath-holding, and free breathing after breath-holding) were recorded and the quality of correlation between them was analyzed. For a single marker motion, its correlation with the internal target was analyzed using cross-covariance function. For the multiple markers, their correlation with the internal target was analyzed based on additive model. RESULT:Seven patients undergoing radiotherapy with right upper or middle lobe lesions were enrolled in this study. Statistic analysis based on the internal-external motion signals shows that the effect of marker location on the quality of its correlation with the internal target is varied from patient to patient. There was no specific marker location where consistently demonstrated superior quality of correlation with the internal target motion over three breathing sessions for all patients. As the composite surrogate signal which was generated from the motions of multiple external markers was used to correlate the internal target motion, significant improvement of the quality of correlation was achieved. CONCLUSION:The correlation of external marker to the internal target could be influenced by several factors such as patient population, marker locations, and breathing patterns, considerably. The quality of correlation and predictability to the internal target furnished by a single external marker is inferior to that of the composite signal generated from multiple external markers. The use of composite signal shows great potential in improving the predictability of internal target motion and presents an effective way to track tumor more accurately.Item Open Access The role of whole brain radiation therapy in the management of melanoma brain metastases.(Radiat Oncol, 2014-06-22) Dyer, Michael A; Arvold, Nils D; Chen, Yu-Hui; Pinnell, Nancy E; Mitin, Timur; Lee, Eudocia Q; Hodi, F Stephen; Ibrahim, Nageatte; Weiss, Stephanie E; Kelly, Paul J; Floyd, Scott R; Mahadevan, Anand; Alexander, Brian MBACKGROUND: Brain metastases are common in patients with melanoma, and optimal management is not well defined. As melanoma has traditionally been thought of as "radioresistant," the role of whole brain radiation therapy (WBRT) in particular is unclear. We conducted this retrospective study to identify prognostic factors for patients treated with stereotactic radiosurgery (SRS) for melanoma brain metastases and to investigate the role of additional up-front treatment with whole brain radiation therapy (WBRT). METHODS: We reviewed records of 147 patients who received SRS as part of initial management of their melanoma brain metastases from January 2000 through June 2010. Overall survival (OS) and time to distant intracranial progression were calculated using the Kaplan-Meier method. Prognostic factors were evaluated using the Cox proportional hazards model. RESULTS: WBRT was employed with SRS in 27% of patients and as salvage in an additional 22%. Age at SRS > 60 years (hazard ratio [HR] 0.64, p = 0.05), multiple brain metastases (HR 1.90, p = 0.008), and omission of up-front WBRT (HR 2.24, p = 0.005) were associated with distant intracranial progression on multivariate analysis. Extensive extracranial metastases (HR 1.86, p = 0.0006), Karnofsky Performance Status (KPS) ≤ 80% (HR 1.58, p = 0.01), and multiple brain metastases (HR 1.40, p = 0.06) were associated with worse OS on univariate analysis. Extensive extracranial metastases (HR 1.78, p = 0.001) and KPS (HR 1.52, p = 0.02) remained significantly associated with OS on multivariate analysis. In patients with absent or stable extracranial disease, multiple brain metastases were associated with worse OS (multivariate HR 5.89, p = 0.004), and there was a trend toward an association with worse OS when up-front WBRT was omitted (multivariate HR 2.56, p = 0.08). CONCLUSIONS: Multiple brain metastases and omission of up-front WBRT (particularly in combination) are associated with distant intracranial progression. Improvement in intracranial disease control may be especially important in the subset of patients with absent or stable extracranial disease, where the competing risk of death from extracranial disease is low. These results are hypothesis generating and require confirmation from ongoing randomized trials.