Browsing by Subject "Stress, Mechanical"
Now showing 1 - 7 of 7
Results Per Page
Sort Options
Item Open Access Cartilage mechanics in the guinea pig model of osteoarthritis studied with an osmotic loading method.(Osteoarthritis and cartilage, 2004-05) Flahiff, Charlene M; Kraus, Virginia B; Huebner, Janet L; Setton, Lori ATo determine the material properties of articular cartilage in the Hartley guinea pig model of spontaneous osteoarthritis.Cartilage-bone samples from the medial femoral condyle and tibial plateau of 12 month-old guinea pig knees were subjected to osmotic loading. Site-matched swelling strains and fixed charge density values were used in a triphasic theoretical model for cartilage swelling to determine the modulus of the cartilage solid matrix. The degree of cartilage degeneration was assessed in adjacent tissue sections using a semi-quantitative histological grading scheme.Decreased values for both moduli and surface zone fixed charge density were associated with increasing grades of cartilage degeneration. Decreases in moduli reflect damage to the collagen matrix, which give rise to greater swelling strains.Histological evidence of cartilage degeneration was associated with impaired cartilage mechanics in the aging Hartley guinea pig.Item Open Access Continuous shear stress alters metabolism, mass-transport, and growth in electroactive biofilms independent of surface substrate transport.(Scientific reports, 2019-02) Jones, A-Andrew D; Buie, Cullen RElectroactive bacteria such as Geobacter sulfurreducens and Shewanella onedensis produce electrical current during their respiration; this has been exploited in bioelectrochemical systems. These bacteria form thicker biofilms and stay more active than soluble-respiring bacteria biofilms because their electron acceptor is always accessible. In bioelectrochemical systems such as microbial fuel cells, corrosion-resistant metals uptake current from the bacteria, producing power. While beneficial for engineering applications, collecting current using corrosion resistant metals induces pH stress in the biofilm, unlike the naturally occurring process where a reduced metal combines with protons released during respiration. To reduce pH stress, some bioelectrochemical systems use forced convection to enhance mass transport of both nutrients and byproducts; however, biofilms' small pore size limits convective transport, thus, reducing pH stress in these systems remains a challenge. Understanding how convection is necessary but not sufficient for maintaining biofilm health requires decoupling mass transport from momentum transport (i.e. fluidic shear stress). In this study we use a rotating disc electrode to emulate a practical bioelectrochemical system, while decoupling mass transport from shear stress. This is the first study to isolate the metabolic and structural changes in electroactive biofilms due to shear stress. We find that increased shear stress reduces biofilm development time while increasing its metabolic rate. Furthermore, we find biofilm health is negatively affected by higher metabolic rates over long-term growth due to the biofilm's memory of the fluid flow conditions during the initial biofilm development phases. These results not only provide guidelines for improving performance of bioelectrochemical systems, but also reveal features of biofilm behavior. Results of this study suggest that optimized reactors may initiate operation at high shear to decrease development time before decreasing shear for steady-state operation. Furthermore, this biofilm memory discovered will help explain the presence of channels within biofilms observed in other studies.Item Open Access Effect of surface topography on in vitro osteoblast function and mechanical performance of 3D printed titanium.(Journal of biomedical materials research. Part A, 2021-10) Abar, Bijan; Kelly, Cambre; Pham, Anh; Allen, Nicholas; Barber, Helena; Kelly, Alexander; Mirando, Anthony J; Hilton, Matthew J; Gall, Ken; Adams, Samuel BCritical-sized defects remain a significant challenge in orthopaedics. 3D printed scaffolds are a promising treatment but are still limited due to inconsistent osseous integration. The goal of the study is to understand how changing the surface roughness of 3D printed titanium either by surface treatment or artificially printing rough topography impacts the mechanical and biological properties of 3D printed titanium. Titanium tensile samples and discs were printed via laser powder bed fusion. Roughness was manipulated by post-processing printed samples or by directly printing rough features. Experimental groups in order of increasing surface roughness were Polished, Blasted, As Built, Sprouts, and Rough Sprouts. Tensile behavior of samples showed reduced strength with increasing surface roughness. MC3T3 pre-osteoblasts were seeded on discs and analyzed for cellular proliferation, differentiation, and matrix deposition at 0, 2, and 4 weeks. Printing roughness diminished mechanical properties such as tensile strength and ductility without clear benefit to cell growth. Roughness features were printed on mesoscale, unlike samples in literature in which roughness on microscale demonstrated an increase in cell activity. The data suggest that printing artificial roughness on titanium scaffold is not an effective strategy to promote osseous integration.Item Open Access Intracardiac acoustic radiation force impulse (ARFI) and shear wave imaging in pigs with focal infarctions.(IEEE Trans Ultrason Ferroelectr Freq Control, 2013-08) Hollender, Peter; Bradway, David; Wolf, Patrick; Goswami, Robi; Trahey, GreggFour pigs, three with focal infarctions in the apical intraventricular septum (IVS) and/or left ventricular free wall (LVFW), were imaged with an intracardiac echocardiography (ICE) transducer. Custom beam sequences were used to excite the myocardium with focused acoustic radiation force (ARF) impulses and image the subsequent tissue response. Tissue displacement in response to the ARF excitation was calculated with a phase-based estimator, and transverse wave magnitude and velocity were each estimated at every depth. The excitation sequence was repeated rapidly, either in the same location to generate 40 Hz M-modes at a single steering angle, or with a modulated steering angle to synthesize 2-D displacement magnitude and shear wave velocity images at 17 points in the cardiac cycle. Both types of images were acquired from various views in the right and left ventricles, in and out of infarcted regions. In all animals, acoustic radiation force impulse (ARFI) and shear wave elasticity imaging (SWEI) estimates indicated diastolic relaxation and systolic contraction in noninfarcted tissues. The M-mode sequences showed high beat-to-beat spatio-temporal repeatability of the measurements for each imaging plane. In views of noninfarcted tissue in the diseased animals, no significant elastic remodeling was indicated when compared with the control. Where available, views of infarcted tissue were compared with similar views from the control animal. In views of the LVFW, the infarcted tissue presented as stiff and non-contractile compared with the control. In a view of the IVS, no significant difference was seen between infarcted and healthy tissue, whereas in another view, a heterogeneous infarction was seen to be presenting itself as non-contractile in systole.Item Open Access Measurement of intracellular strain on deformable substrates with texture correlation.(J Biomech, 2007) Gilchrist, Christopher L; Witvoet-Braam, Sietske W; Guilak, Farshid; Setton, Lori AMechanical stimuli are important factors that regulate cell proliferation, survival, metabolism and motility in a variety of cell types. The relationship between mechanical deformation of the extracellular matrix and intracellular deformation of cellular sub-regions and organelles has not been fully elucidated, but may provide new insight into the mechanisms involved in transducing mechanical stimuli to biological responses. In this study, a novel fluorescence microscopy and image analysis method was applied to examine the hypothesis that mechanical strains are fully transferred from a planar, deformable substrate to cytoplasmic and intranuclear regions within attached cells. Intracellular strains were measured in cells derived from the anulus fibrosus of the intervertebral disc when attached to an elastic silicone membrane that was subjected to tensile stretch. Measurements indicated cytoplasmic strains were similar to those of the underlying substrate, with a strain transfer ratio (STR) of 0.79. In contrast, nuclear strains were much smaller than those of the substrate, with an STR of 0.17. These findings are consistent with previous studies indicating nuclear stiffness is significantly greater than cytoplasmic stiffness, as measured using other methods. This study provides a novel method for the study of cellular mechanics, including a new technique for measuring intranuclear deformations, with evidence of differential magnitudes and patterns of strain transferred from the substrate to cell cytoplasm and nucleus.Item Open Access Synergy between Piezo1 and Piezo2 channels confers high-strain mechanosensitivity to articular cartilage.(Proc Natl Acad Sci U S A, 2014-11-25) Lee, Whasil; Leddy, Holly A; Chen, Yong; Lee, Suk Hee; Zelenski, Nicole A; McNulty, Amy L; Wu, Jason; Beicker, Kellie N; Coles, Jeffrey; Zauscher, Stefan; Grandl, Jörg; Sachs, Frederick; Guilak, Farshid; Liedtke, Wolfgang BDiarthrodial joints are essential for load bearing and locomotion. Physiologically, articular cartilage sustains millions of cycles of mechanical loading. Chondrocytes, the cells in cartilage, regulate their metabolic activities in response to mechanical loading. Pathological mechanical stress can lead to maladaptive cellular responses and subsequent cartilage degeneration. We sought to deconstruct chondrocyte mechanotransduction by identifying mechanosensitive ion channels functioning at injurious levels of strain. We detected robust expression of the recently identified mechanosensitive channels, PIEZO1 and PIEZO2. Combined directed expression of Piezo1 and -2 sustained potentiated mechanically induced Ca(2+) signals and electrical currents compared with single-Piezo expression. In primary articular chondrocytes, mechanically evoked Ca(2+) transients produced by atomic force microscopy were inhibited by GsMTx4, a PIEZO-blocking peptide, and by Piezo1- or Piezo2-specific siRNA. We complemented the cellular approach with an explant-cartilage injury model. GsMTx4 reduced chondrocyte death after mechanical injury, suggesting a possible therapy for reducing cartilage injury and posttraumatic osteoarthritis by attenuating Piezo-mediated cartilage mechanotransduction of injurious strains.Item Open Access The role of extracellular matrix elasticity and composition in regulating the nucleus pulposus cell phenotype in the intervertebral disc: a narrative review.(J Biomech Eng, 2014-02) Hwang, Priscilla Y; Chen, Jun; Jing, Liufang; Hoffman, Brenton D; Setton, Lori AIntervertebral disc (IVD) disorders are a major contributor to disability and societal health care costs. Nucleus pulposus (NP) cells of the IVD exhibit changes in both phenotype and morphology with aging-related IVD degeneration that may impact the onset and progression of IVD pathology. Studies have demonstrated that immature NP cell interactions with their extracellular matrix (ECM) may be key regulators of cellular phenotype, metabolism and morphology. The objective of this article is to review our recent experience with studies of NP cell-ECM interactions that reveal how ECM cues can be manipulated to promote an immature NP cell phenotype and morphology. Findings demonstrate the importance of a soft (<700 Pa), laminin-containing ECM in regulating healthy, immature NP cells. Knowledge of NP cell-ECM interactions can be used for development of tissue engineering or cell delivery strategies to treat IVD-related disorders.