Item Open Access Correcting Motion Artifacts in Multi-Shot Diffusion-Weighted EPI Using Iterative Phase Cycling(2012) Guhaniyogi, ShayanDiffusion-weighted MRI (DWI) is an essential tool in clinical applications such as detecting ischemic stroke, and in research applications studying neuronal connectivity in the brain. Diffusion-weighted imaging with multi-shot echo-planar acquisition (DWEPI) offers several advantages over single-shot EPI, including improved spatial resolution and reduced off-resonance and susceptibility artifacts. However a major limitation of multi-shot DWEPI is its sensitivity to patient motion during the application of diffusion gradients; the motion generates phase errors which vary from shot to shot, resulting in artifacts in the reconstructed image.
Most current methods for correcting motion-induced artifacts involve the use of navigator echoes to estimate the shot-to-shot phase errors. Accurate navigator information comes at the expense of increased scan times however, which is generally undesirable. The aim of this study is to therefore develop and demonstrate the use of an alternative phase estimation technique, iterative phase-cycling, as a new method to correct motion artifacts in DWI without the use of navigators. The developed method involves an iterative column by column estimation of phase errors in the aliased image and reconstruction of an artifact free image using the estimated errors.
In this study the technique was applied to correct artifacts in simulated images, hybrid-simulated images, and true four-shot DWEPI images. Accuracy of the phase-cycling method was evaluated by computing residual image errors and ghost-to-noise ratios after correction. The efficiency of phase-cycling was evaluated by recording computation times of the correction process. Multiple optimization techniques were developed and used in the experiments, and the accuracy/efficiency of these techniques were also assessed.
Results of the experiments demonstrated the ability of phase-cycling to greatly reduce motion-induced artifacts in multi-shot DWEPI at reasonable computation times. The phase-cycling model used in this study accurately estimated linear and nonlinear errors along the frequency encoding direction and linear errors along the phase encoding direction. An additional mathematical framework is presented illustrating the potential of phase-cycling to correct nonlinear errors along the phase encoding direction in future work.
The study establishes the developed technique as a unique and effective method for correcting motion artifacts in DWEPI without the cost of increased scan times.
Item Open Access POCS-based reconstruction of multiplexed sensitivity encoded MRI (POCSMUSE): A general algorithm for reducing motion-related artifacts.(Magn Reson Med, 2015-11) Chu, Mei-Lan; Chang, Hing-Chiu; Chung, Hsiao-Wen; Truong, Trong-Kha; Bashir, Mustafa R; Chen, Nan-kueiPURPOSE: A projection onto convex sets reconstruction of multiplexed sensitivity encoded MRI (POCSMUSE) is developed to reduce motion-related artifacts, including respiration artifacts in abdominal imaging and aliasing artifacts in interleaved diffusion-weighted imaging. THEORY: Images with reduced artifacts are reconstructed with an iterative projection onto convex sets (POCS) procedure that uses the coil sensitivity profile as a constraint. This method can be applied to data obtained with different pulse sequences and k-space trajectories. In addition, various constraints can be incorporated to stabilize the reconstruction of ill-conditioned matrices. METHODS: The POCSMUSE technique was applied to abdominal fast spin-echo imaging data, and its effectiveness in respiratory-triggered scans was evaluated. The POCSMUSE method was also applied to reduce aliasing artifacts due to shot-to-shot phase variations in interleaved diffusion-weighted imaging data corresponding to different k-space trajectories and matrix condition numbers. RESULTS: Experimental results show that the POCSMUSE technique can effectively reduce motion-related artifacts in data obtained with different pulse sequences, k-space trajectories and contrasts. CONCLUSION: POCSMUSE is a general post-processing algorithm for reduction of motion-related artifacts. It is compatible with different pulse sequences, and can also be used to further reduce residual artifacts in data produced by existing motion artifact reduction methods.