ALERT: This system is being upgraded on Tuesday December 12. It will not be available for use for several hours that day while the upgrade is in progress. Deposits to DukeSpace will be disabled on Monday December 11, so no new items are to be added to the repository while the upgrade is in progress. Everything should be back to normal by the end of day, December 12.

Show simple item record

Effects of Drawdown on Water Quality and Temperature in Duke University's Chiller Pond

dc.contributor.advisor Richardson, Curtis J.
dc.contributor.advisor Flanagan, Neal
dc.contributor.author Giuliano, Brooke
dc.date.accessioned 2016-04-21T16:55:11Z
dc.date.available 2016-04-21T16:55:11Z
dc.date.issued 2016-04-21
dc.identifier.uri https://hdl.handle.net/10161/11829
dc.description.abstract The Duke Pond (or chiller pond) collects runoff from 20% of the Duke University campus and serves as a water source to the adjacent evaporative cooling plant. Due to frequent water withdrawals from the chiller plant, the water levels are expected to fluctuate anywhere from one to four feet daily (1.22 m). This project aims to (1) calculate a water budget for the pond, (2) determine the effects of fluctuating water levels on various water quality parameters, (3) assess whether the pond is compliant with state water quality standards, and (4) determine whether the stream temperature is significantly different at the inflow versus the outflow to the pond. An additional goal was to develop a GIS tool that estimates the annual sediment yield from the Duke pond’s watershed using the Universal Soil Loss Equation (USLE). After the pond stabilized I found that dissolved oxygen, pH, temperature, and specific conductance decrease with increasing water levels in the pond. The temperature is not significantly different at the outflow compared to the inflow stream. For the majority of the 8-month sampling period, dissolved oxygen and pH remain compliant with the state standards. Chlorophyll-a had one occurrence where it exceeded the standard. The USLE tool accurately delineates the watershed for the pond and calculates an annual sediment loss of 168.2 lb/ac/yr.
dc.language.iso en_US
dc.subject Duke Chiller Pond
dc.subject Water Quality
dc.subject Stormwater Detention Pond
dc.subject Duke University Wetland Center
dc.title Effects of Drawdown on Water Quality and Temperature in Duke University's Chiller Pond
dc.type Master's project