Development, Validation, and Application of Image-based Noise Addition Tool to Simulate Low Dose Computed Tomography Images

Thumbnail
View / Download
5.7 Mb
Date
2022
Author
alsaihati, njood
Advisor
solomon, justin
Repository Usage Stats
91
views
130
downloads
Abstract

Computed tomography (CT) is one the most used imaging modalities due to its advancements in acquisition time and diagnostic capability. There are Concerns regarding the radiation exposure and its associated cancer risks. Therefore, great effort in research has been focused on minimizing patient dose by generating low-dose simulations. These simulations can be achieved by adding artificial noise into raw projection. However, raw CT data is not easily accessible. The purpose of this master’s project is to validate a simplified noise addition tool that requires only CT images to produce simulated low-dose images. The noise addition tool method aims to generate artificial noise that is similar to real CT noise in terms of magnitude, texture, spatial nonstationary characteristics. The tool was evaluated in terms of noise magnitude and texture through phantom and patient images studies. The tool was incorporated into routine clinical CT protocol review to demonstrate its usefulness. The first study of evaluating the tool was performed by imaging phantoms. A thorax anthropomorphic phantom and a multi-sized image quality phantom were scanned at different dose levels and reconstruction settings. Noise magnitude in the simulated low-dose images was compared to the actual images. Furthermore, the noise texture was also assessed through the noise power spectrum (NPS). The second study of evaluating the tool was performed using patient images. The images were obtained at high and low doses from various CT examinations and different reconstruction settings. The noise addition tool simulated low-dose images from the original high-dose images. The noise magnitude of the simulated low-dose images was compared to the actual low-dose images. The utility of the noise addition tool was applied to dose reduction of multiple myeloma skeletal CT protocol. Data from patients who underwent multiple myeloma scanning were retrospectively analyzed for radiation dose and image quality assessment. The tool was used to simulate the patient images at different low-dose levels. A musculoskeletal radiologist assessed the simulated images to determine the lowest possible dose. From the phantom images study, the noise magnitude in the simulated low-dose images compared to the actual images had a relative difference of xx. Also, NPS was visually comparable. From the patient images study, the noise magnitude comparison had a relative difference of 2.38%. In addition, the effective radiation dose of the multiple myeloma CT protocol was reduced by xx. In conclusion, the noise addition tool produced simulated CT images with realistic noise properties from standard dose CT images. The tool demonstrated its potential in estimating reduced dose protocols.

Description
Master's thesis
Type
Master's thesis
Department
Medical Physics
Subject
Medical imaging
Permalink
https://hdl.handle.net/10161/25320
Citation
alsaihati, njood (2022). Development, Validation, and Application of Image-based Noise Addition Tool to Simulate Low Dose Computed Tomography Images. Master's thesis, Duke University. Retrieved from https://hdl.handle.net/10161/25320.
Collections
  • Masters Theses
More Info
Show full item record
Creative Commons License
This work is licensed under a Creative Commons Attribution-Noncommercial-No Derivative Works 3.0 United States License.

Rights for Collection: Masters Theses


Works are deposited here by their authors, and represent their research and opinions, not that of Duke University. Some materials and descriptions may include offensive content. More info

Make Your Work Available Here

How to Deposit

Browse

All of DukeSpaceCommunities & CollectionsAuthorsTitlesTypesBy Issue DateDepartmentsAffiliations of Duke Author(s)SubjectsBy Submit DateThis CollectionAuthorsTitlesTypesBy Issue DateDepartmentsAffiliations of Duke Author(s)SubjectsBy Submit Date

My Account

LoginRegister

Statistics

View Usage Statistics
Duke University Libraries

Contact Us

411 Chapel Drive
Durham, NC 27708
(919) 660-5870
Perkins Library Service Desk

Digital Repositories at Duke

  • Report a problem with the repositories
  • About digital repositories at Duke
  • Accessibility Policy
  • Deaccession and DMCA Takedown Policy

TwitterFacebookYouTubeFlickrInstagramBlogs

Sign Up for Our Newsletter
  • Re-use & Attribution / Privacy
  • Harmful Language Statement
  • Support the Libraries
Duke University