Generalized Linear Binning to Compare Hyperpolarized 129Xe Ventilation Maps Derived from 3D Radial Gas Exchange Versus Dedicated Multislice Gradient Echo MRI.

dc.contributor.author

He, Mu

dc.contributor.author

Wang, Ziyi

dc.contributor.author

Rankine, Leith

dc.contributor.author

Luo, Sheng

dc.contributor.author

Nouls, John

dc.contributor.author

Virgincar, Rohan

dc.contributor.author

Mammarappallil, Joseph

dc.contributor.author

Driehuys, Bastiaan

dc.date.accessioned

2020-01-01T15:43:51Z

dc.date.available

2020-01-01T15:43:51Z

dc.date.issued

2019-11-27

dc.date.updated

2020-01-01T15:43:47Z

dc.description.abstract

RATIONALE:Hyperpolarized 129Xe ventilation MRI is typically acquired using multislice fast gradient recalled echo (GRE), but interleaved 3D radial 129Xe gas transfer MRI now provides dissolved-phase and ventilation images from a single breath. To investigate whether these ventilation images provide equivalent quantitative metrics, we introduce generalized linear binning analysis. METHODS:This study included 36 patients who had undergone both multislice GRE ventilation and 3D radial gas exchange imaging. Images were then quantified by linear binning to classify voxels into one of four clusters: ventilation defect percentage (VDP), Low-, Medium- or High-ventilation percentage (LVP, MVP, HVP). For 3D radial images, linear binning thresholds were generalized using a Box-Cox rescaled reference histogram. We compared the cluster populations from the two ventilation acquisitions both numerically and spatially. RESULTS:Interacquisition Bland-Altman limits of agreement for the clusters between 3D radial vs GRE were (-7% to 5%) for VDP, (-10% to 14%) for LVP, and (-8% to 8%) for HVP. While binning maps were qualitatively similar between acquisitions, their spatial overlap was modest for VDP (Dice = 0.5 ± 0.2), and relatively poor for LVP (0.3 ± 0.1) and HVP (0.2 ± 0.1). CONCLUSION:Both acquisitions yield reasonably concordant VDP and qualitatively similar maps. However, poor regional agreement (Dice) suggests that the two acquisitions cannot yet be used interchangeably. However, further improvements in 3D radial resolution and reconciliation of bias field correction may well obviate the need for a dedicated ventilation scan in many cases.

dc.identifier

S1076-6332(19)30530-6

dc.identifier.issn

1076-6332

dc.identifier.issn

1878-4046

dc.identifier.uri

https://hdl.handle.net/10161/19675

dc.language

eng

dc.publisher

Elsevier BV

dc.relation.ispartof

Academic radiology

dc.relation.isversionof

10.1016/j.acra.2019.10.016

dc.subject

3D Radial

dc.subject

Acquisition

dc.subject

Hyperpolarized (129)Xe MRI

dc.subject

Multislice GRE

dc.subject

Quantification

dc.title

Generalized Linear Binning to Compare Hyperpolarized 129Xe Ventilation Maps Derived from 3D Radial Gas Exchange Versus Dedicated Multislice Gradient Echo MRI.

dc.type

Journal article

duke.contributor.orcid

Luo, Sheng|0000-0003-4214-5809

duke.contributor.orcid

Driehuys, Bastiaan|0000-0002-1236-4210

pubs.organisational-group

School of Medicine

pubs.organisational-group

Duke

pubs.organisational-group

Radiology

pubs.organisational-group

Clinical Science Departments

pubs.organisational-group

Duke Clinical Research Institute

pubs.organisational-group

Institutes and Centers

pubs.organisational-group

Biostatistics & Bioinformatics

pubs.organisational-group

Basic Science Departments

pubs.publication-status

Published

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
2019He_et_al2019Acad_Radiol.pdf
Size:
4.29 MB
Format:
Adobe Portable Document Format
Description: