Imaging system QA of a medical accelerator, Novalis Tx, for IGRT per TG 142: our 1 year experience.
| dc.contributor.author | Chang, Z | |
| dc.contributor.author | Bowsher, J | |
| dc.contributor.author | Cai, J | |
| dc.contributor.author | Yoo, S | |
| dc.contributor.author | Wang, Z | |
| dc.contributor.author | Adamson, J | |
| dc.contributor.author | Ren, L | |
| dc.contributor.author | Yin, FF | |
| dc.date.accessioned | 2019-10-04T16:11:40Z | |
| dc.date.available | 2019-10-04T16:11:40Z | |
| dc.date.issued | 2012-07-05 | |
| dc.date.updated | 2019-10-04T16:11:38Z | |
| dc.description.abstract | American Association of Physicists in Medicine (AAPM) task group (TG) 142 has recently published a report to update recommendations of the AAPM TG 40 report and add new recommendations concerning medical accelerators in the era of image-guided radiation therapy (IGRT). The recommendations of AAPM TG 142 on IGRT are timely. In our institute, we established a comprehensive imaging QA program on a medical accelerator based on AAPM TG 142 and implemented it successfully. In this paper, we share our one-year experience and performance evaluation of an OBI capable linear accelerator, Novalis Tx, per TG 142 guidelines. | |
| dc.identifier.issn | 1526-9914 | |
| dc.identifier.issn | 1526-9914 | |
| dc.identifier.uri | ||
| dc.language | eng | |
| dc.publisher | Wiley | |
| dc.relation.ispartof | Journal of applied clinical medical physics | |
| dc.relation.isversionof | 10.1120/jacmp.v13i4.3754 | |
| dc.subject | Humans | |
| dc.subject | Image Enhancement | |
| dc.subject | Radiotherapy Planning, Computer-Assisted | |
| dc.subject | Calibration | |
| dc.subject | Particle Accelerators | |
| dc.subject | Quality Control | |
| dc.subject | Radiotherapy, Image-Guided | |
| dc.title | Imaging system QA of a medical accelerator, Novalis Tx, for IGRT per TG 142: our 1 year experience. | |
| dc.type | Journal article | |
| duke.contributor.orcid | Adamson, J|0000-0002-7868-5631 | |
| duke.contributor.orcid | Yin, FF|0000-0002-2025-4740|0000-0003-1064-2149 | |
| pubs.begin-page | 3754 | |
| pubs.issue | 4 | |
| pubs.organisational-group | School of Medicine | |
| pubs.organisational-group | Duke | |
| pubs.organisational-group | Duke Cancer Institute | |
| pubs.organisational-group | Institutes and Centers | |
| pubs.organisational-group | Radiation Oncology | |
| pubs.organisational-group | Clinical Science Departments | |
| pubs.organisational-group | Duke Kunshan University Faculty | |
| pubs.organisational-group | Duke Kunshan University | |
| pubs.publication-status | Published | |
| pubs.volume | 13 |