Responsive neurostimulation detections: "Recognizing the unseen".

dc.contributor.author

Haskell-Mendoza, Aden P

dc.contributor.author

Ramani, Praveen

dc.contributor.author

Dhoot, Roshni

dc.contributor.author

Parikh, Prachi

dc.contributor.author

Frauscher, Birgit

dc.contributor.author

Sinha, Saurabh R

dc.contributor.author

Muh, Carrie R

dc.contributor.author

Southwell, Derek

dc.contributor.author

Husain, Aatif

dc.contributor.author

Agashe, Shruti

dc.date.accessioned

2025-07-23T14:05:18Z

dc.date.available

2025-07-23T14:05:18Z

dc.date.issued

2025-05

dc.description.abstract

Background

Closed-loop responsive neurostimulation (RNS) is an established non-resective neuromodulatory therapy for individuals with drug-resistant epilepsy (DRE). RNS systems are typically programmed to detect and respond to predefined seizure onset patterns, with detector settings often remaining unchanged for extended periods.

Aims

To describe the delayed recognition of a novel seizure onset pattern in the acute and chronic clinical settings.

Methods

The case of a 35-year-old female with history of drug-refractory temporal lobe epilepsy who presented with increasing seizure frequency and headaches was reviewed.

Results

We demonstrate emergence of a new seizure onset pattern in a 35-year-old female with DRE who had undergone RNS implantation 5.5 years prior to presentation. Guided primarily by strong clinical suspicion, with live electrocorticography (ECoG) serving as a confirmatory tool, we identified a previously unrecognized seizure onset pattern linked to a rare, delayed intraparenchymal hemorrhage associated with an RNS lead. Longitudinal ECoG analysis in this patient, who experienced over a 95% reduction in seizures since implantation, revealed evolving seizure patterns over several years that contributed to delayed detections.

Conclusion

This case underscores the risk of misdiagnosis when acute changes in seizure patterns occur, in the context of detections programmed to identify specific patterns. Longitudinal analysis of ECoG in the same patient showed changes in seizure patterns over several years that were detected with delay, highlighting importance of vigilant detection monitoring.
dc.identifier.issn

1294-9361

dc.identifier.issn

1950-6945

dc.identifier.uri

https://hdl.handle.net/10161/33035

dc.language

eng

dc.publisher

Wiley

dc.relation.ispartof

Epileptic disorders : international epilepsy journal with videotape

dc.relation.isversionof

10.1002/epd2.70049

dc.rights.uri

https://creativecommons.org/licenses/by-nc/4.0

dc.subject

intracerebral hemorrhage

dc.subject

neuromodulation

dc.subject

responsive neurostimulator

dc.subject

seizure networks

dc.subject

temporal lobe epilepsy

dc.title

Responsive neurostimulation detections: "Recognizing the unseen".

dc.type

Journal article

duke.contributor.orcid

Frauscher, Birgit|0000-0001-6064-1529

duke.contributor.orcid

Muh, Carrie R|0000-0002-3764-4163

duke.contributor.orcid

Southwell, Derek|0000-0001-6465-3869

duke.contributor.orcid

Husain, Aatif|0000-0001-7954-1755

duke.contributor.orcid

Agashe, Shruti|0000-0003-0515-6066

pubs.organisational-group

Duke

pubs.organisational-group

Pratt School of Engineering

pubs.organisational-group

School of Medicine

pubs.organisational-group

Clinical Science Departments

pubs.organisational-group

Institutes and Centers

pubs.organisational-group

Biomedical Engineering

pubs.organisational-group

Duke Clinical Research Institute

pubs.organisational-group

Neurology

pubs.organisational-group

Neurology, Epilepsy and Sleep

pubs.organisational-group

Neurosurgery

pubs.publication-status

Published

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Epileptic Disorders - 2025 - Haskell‐Mendoza - Responsive neurostimulation detections Recognizing the unseen.pdf
Size:
947.24 KB
Format:
Adobe Portable Document Format
Description:
Accepted version