Smartphone ECG for evaluation of STEMI: Results of the ST LEUIS Pilot Study

dc.contributor.author

Muhlestein, Joseph Boone

dc.contributor.author

Le, Viet

dc.contributor.author

Albert, David

dc.contributor.author

Moreno, Fidela Ll

dc.contributor.author

Anderson, Jeffrey L

dc.contributor.author

Yanowitz, Frank

dc.contributor.author

Vranian, Robert B

dc.contributor.author

Barsness, Gregory W

dc.contributor.author

Bethea, Charles F

dc.contributor.author

Severance, Harry W

dc.contributor.author

Ramo, Barry

dc.contributor.author

Pierce, John

dc.contributor.author

Barbagelata, Alejandro

dc.contributor.author

Muhlestein, Joseph Brent

dc.date.accessioned

2015-09-10T14:30:14Z

dc.date.issued

2015-01-01

dc.description.abstract

© 2015 Elsevier Inc. All rights reserved.Background 12-lead ECG is a critical component of initial evaluation of cardiac ischemia, but has traditionally been limited to large, dedicated equipment in medical care environments. Smartphones provide a potential alternative platform for the extension of ECG to new care settings and to improve timeliness of care. Objective To gain experience with smartphone electrocardiography prior to designing a larger multicenter study evaluating standard 12-lead ECG compared to smartphone ECG. Methods 6 patients for whom the hospital STEMI protocol was activated were evaluated with traditional 12-lead ECG followed immediately by a smartphone ECG using right (VnR) and left (VnL) limb leads for precordial grounding. The AliveCor™ Heart Monitor was utilized for this study. All tracings were taken prior to catheterization or immediately after revascularization while still in the catheterization laboratory. Results The smartphone ECG had excellent correlation with the gold standard 12-lead ECG in all patients. Four out of six tracings were judged to meet STEMI criteria on both modalities as determined by three experienced cardiologists, and in the remaining two, consensus indicated a non-STEMI ECG diagnosis. No significant difference was noted between VnR and VnL. Conclusions Smartphone based electrocardiography is a promising, developing technology intended to increase availability and speed of electrocardiographic evaluation. This study confirmed the potential of a smartphone ECG for evaluation of acute ischemia and the feasibility of studying this technology further to define the diagnostic accuracy, limitations and appropriate use of this new technology.

dc.identifier.eissn

1532-8430

dc.identifier.issn

0022-0736

dc.identifier.uri

https://hdl.handle.net/10161/10599

dc.publisher

Churchill Livingstone Inc.

dc.relation.ispartof

Journal of Electrocardiology

dc.relation.isversionof

10.1016/j.jelectrocard.2014.11.005

dc.title

Smartphone ECG for evaluation of STEMI: Results of the ST LEUIS Pilot Study

dc.type

Journal article

duke.contributor.orcid

Severance, Harry W|0000-0001-6057-643X

duke.contributor.orcid

Barbagelata, Alejandro|0000-0001-6803-2605

pubs.begin-page

249

pubs.end-page

259

pubs.issue

2

pubs.organisational-group

Clinical Science Departments

pubs.organisational-group

Duke

pubs.organisational-group

Medicine

pubs.organisational-group

Medicine, Cardiology

pubs.organisational-group

School of Medicine

pubs.publication-status

Published

pubs.volume

48

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Muhlestein et al_ECG for evaluation of STEMI.pdf
Size:
620.41 KB
Format:
Adobe Portable Document Format
Description:
Submitted version