dc.description.abstract

BACKGROUND: Stent related occlusion and migration remains a problem despite attempts to improve stent design over this time period. Flanged polyethylene plastic stents (FPS) remains the stent of choice in most centers. Early failure of stents placed for malignant extrahepatic biliary strictures (MEBS) has not previously been studied in detail. We set out to determine the incidence and reasons for biliary stent change within 30 days of the index procedure in a large tertiary center population during a period where (FPS) was the sole plastic stent used. METHODS: Retrospective analysis of endoscopic retrograde cholangiography (ERCP) was undertaken in patients who were stented for presumed or known MEBS between 1993 and 2001. Patients who required repeat stenting within 30 days were identified. RESULTS: All 508 patients were stented for MEBS. 5.7% of patients had a total of 34 repeat stenting procedures within 30 days of the index procedure; 27of 29 index stents were plastic, 2 were self-expandable metal stents (SEMS), 20 (3.9%) patients had stent failure as the reason for a stent exchange (plastic stent occlusion n = 15, mean time to stent change 14 ± 8.3 days; metal stent occlusion n = 2, mean time to stent change 24.5 ± 7.8 days; plastic stent migration n = 3, mean time to stent change 25 ± 5.3 days). There was a statistically significant difference in the time to stent change between the occluded plastic stent and migrated plastic stent cases (P = 0.045, 95% CI -21.7 to -0.29). 6 patients spent at least 2 additional days in hospital as a result of stent failure. CONCLUSIONS: Early stent failure is an uncommon problem, especially in patients with SEMS. Early plastic stent failure appears to occur sooner with stent occlusion than with stent migration. Early stent failure is associated with significant morbidity and bears an economic impact in additional procedures and hospital stay.

dc.identifier

http://www.ncbi.nlm.nih.gov/pubmed/27785181

dc.identifier.issn

1918-2805

dc.identifier.uri

https://hdl.handle.net/10161/13064

dc.language

eng

dc.publisher

Elmer Press, Inc.

dc.relation.ispartof

Gastroenterology Res

dc.relation.isversionof

10.4021/gr420w

dc.subject

Bile duct stricture

dc.subject

Cancer

dc.subject

ERCP

dc.title

Repeat Procedures Within 30 days in Patients Stented for Malignant Distal Biliary Strictures: Experience of 508 Patients at a Tertiary Referral Center.

dc.type

Journal article

pubs.author-url

http://www.ncbi.nlm.nih.gov/pubmed/27785181

pubs.begin-page

57

pubs.end-page

62

pubs.issue

2

pubs.organisational-group

Clinical Science Departments

pubs.organisational-group

Duke

pubs.organisational-group

Medicine

pubs.organisational-group

Medicine, Gastroenterology

pubs.organisational-group

School of Medicine

pubs.publication-status

Published

pubs.volume

5

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Repeat Procedures Within 30 days in Patients Stented for Malignant Distal Biliary Strictures: Experience of 508 Patients at a Tertiary Referral Center.pdf
Size:
555.36 KB
Format:
Adobe Portable Document Format
Description:
Published version