Optimization of reduced-dose MDCT of thoracic aorta using iterative reconstruction.

dc.contributor.author

Töre, Hüseyin Gürkan

dc.contributor.author

Entezari, Pegah

dc.contributor.author

Chalian, Hamid

dc.contributor.author

Gonzalez-Guindalini, Fernanda Dias

dc.contributor.author

Botelho, Marcos Paulo Ferreira

dc.contributor.author

Yaghmai, Vahid

dc.date.accessioned

2019-04-02T17:59:53Z

dc.date.available

2019-04-02T17:59:53Z

dc.date.issued

2014-01

dc.date.updated

2019-04-02T17:59:52Z

dc.description.abstract

OBJECTIVE: To evaluate the contribution of iterative reconstruction on image quality of reduced-dose multidetector computed tomography of the thoracic aorta. METHODS: A torso phantom was scanned using two tube potentials (80 and 120 kVp) and five different tube currents (110, 75, 40, 20, and 10 mAs). All images were reconstructed with both filtered back projection (FBP) and iterative reconstruction. Aortic attenuation, image noise within the thoracic aorta, signal-to-noise ratio, and sharpness of the aortic wall were quantified in the phantom for the two reconstruction algorithms. Data were analyzed using paired t test. A value of P < 0.05 was considered significant. RESULTS: The aortic attenuation was similar for FBP and iterative reconstruction (P > 0.05). Image noise level was lower (P < 0.0001), and image sharpness was higher (P = 0.046) with iterative reconstruction. Signal-to-noise ratios were higher with iterative reconstruction compared with those with FBP (P < 0.0001). Signal-to-noise ratio at 80 kVp with iterative reconstruction (9.8 ± 4.4) was similar to the signal-to-noise ratio at 120 kVp with FBP (8.4 ± 3.3) (P = 0.196). CONCLUSIONS: Less image noise and higher image sharpness may be achieved with iterative reconstruction in reduced-dose multidetector computed tomography of the thoracic aorta.

dc.identifier

00004728-201401000-00013

dc.identifier.issn

0363-8715

dc.identifier.issn

1532-3145

dc.identifier.uri

https://hdl.handle.net/10161/18299

dc.language

eng

dc.publisher

Ovid Technologies (Wolters Kluwer Health)

dc.relation.ispartof

Journal of computer assisted tomography

dc.relation.isversionof

10.1097/rct.0b013e3182a213cd

dc.subject

Aorta, Thoracic

dc.subject

Humans

dc.subject

Radiographic Image Interpretation, Computer-Assisted

dc.subject

Radiation Dosage

dc.subject

Phantoms, Imaging

dc.subject

Algorithms

dc.subject

Multidetector Computed Tomography

dc.subject

Signal-To-Noise Ratio

dc.title

Optimization of reduced-dose MDCT of thoracic aorta using iterative reconstruction.

dc.type

Journal article

duke.contributor.orcid

Chalian, Hamid|0000-0001-8357-7347

pubs.begin-page

72

pubs.end-page

76

pubs.issue

1

pubs.organisational-group

School of Medicine

pubs.organisational-group

Duke

pubs.organisational-group

Radiology, Cardiothoracic Imaging

pubs.organisational-group

Radiology

pubs.organisational-group

Clinical Science Departments

pubs.publication-status

Published

pubs.volume

38

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
application-pdf.pdf
Size:
1.18 MB
Format:
Adobe Portable Document Format
Description:
Published version