Organ Doses from CT Localizer Radiographs: Development, Validation, and Application of a Monte Carlo Estimation Technique.

dc.contributor.author

Hoye, Jocelyn

dc.contributor.author

Sharma, Shobhit

dc.contributor.author

Zhang, Yakun

dc.contributor.author

Fu, Wanyi

dc.contributor.author

Ria, Francesco

dc.contributor.author

Kapadia, Anuj

dc.contributor.author

Segars, W Paul

dc.contributor.author

Wilson, Joshua

dc.contributor.author

Samei, Ehsan

dc.date.accessioned

2019-08-28T15:42:04Z

dc.date.available

2019-08-28T15:42:04Z

dc.date.issued

2019-08-23

dc.date.updated

2019-08-28T15:42:03Z

dc.description.abstract

PURPOSE:The purpose of this study was to simulate and validate organ doses from different CT localizer radiograph geometries using Monte Carlo methods for a population of patients. METHODS:A Monte Carlo method was developed to estimate organ doses from CT localizer radiographs using PENELOPE. The method was validated by comparing dosimetry estimates with measurements using an anthropomorphic phantom imbedded with thermoluminescent dosimeters (TLDs) scanned on a commercial CT system (Siemens SOMATOM Flash). The Monte Carlo simulation platform was then applied to conduct a population study with fifty-seven adult computational phantoms (XCAT). In the population study, clinically relevant chest localizer protocols were simulated with the x-ray tube in anterior-posterior (AP), right lateral, and PA positions. Mean organ doses and associated standard deviations (in mGy) were then estimated for all simulations. The obtained organ doses were studied as a function of patient chest diameter. Organ doses for breast and lung were compared across different views and represented as a percentage of organ doses from rotational CT scans. RESULTS:The validation study showed an agreement between the Monte Carlo and physical TLD measurements with a maximum percent difference of 15.5% and a mean difference of 3.5% across all organs. The XCAT population study showed that breast dose from AP localizers was the highest with a mean value of 0.24 mGy across patients, while the lung dose was relatively consistent across different localizer geometries. The organ dose estimates were found to vary across the patient population, partially explained by the changes in the patient chest diameter. The average effective dose was 0.18 mGy for AP, 0.09 mGy for lateral, and 0.08 mGy for PA localizer. CONCLUSION:A platform to estimate organ doses in CT localizer scans using Monte Carlo methods was implemented and validated based on comparison with physical dose measurements. The simulation platform was applied to a virtual patient population, where the localizer organ doses were found to range within 0.4-8.6% of corresponding organ doses for a typical CT scan, 0.2-3.3% of organ doses for a CT pulmonary angiography scan, and 1.1-20.8% of organ doses for a low dose lung cancer screening scan.

dc.identifier.issn

0094-2405

dc.identifier.issn

2473-4209

dc.identifier.uri

https://hdl.handle.net/10161/19242

dc.language

eng

dc.publisher

Wiley

dc.relation.ispartof

Medical physics

dc.relation.isversionof

10.1002/mp.13781

dc.title

Organ Doses from CT Localizer Radiographs: Development, Validation, and Application of a Monte Carlo Estimation Technique.

dc.type

Journal article

duke.contributor.orcid

Wilson, Joshua|0000-0002-4175-6301

duke.contributor.orcid

Samei, Ehsan|0000-0001-7451-3309

pubs.organisational-group

Student

pubs.organisational-group

Duke

pubs.organisational-group

Physics

pubs.organisational-group

Trinity College of Arts & Sciences

pubs.organisational-group

School of Medicine

pubs.organisational-group

Radiology

pubs.organisational-group

Clinical Science Departments

pubs.publication-status

Published

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
mp.13781_accepted_article.pdf
Size:
888.98 KB
Format:
Adobe Portable Document Format
Description:
Accepted version