Prospective multicenter assessment of risk factors for rod fracture following surgery for adult spinal deformity.

dc.contributor.author

Smith, Justin S

dc.contributor.author

Shaffrey, Ellen

dc.contributor.author

Klineberg, Eric

dc.contributor.author

Shaffrey, Christopher I

dc.contributor.author

Lafage, Virginie

dc.contributor.author

Schwab, Frank J

dc.contributor.author

Protopsaltis, Themistocles

dc.contributor.author

Scheer, Justin K

dc.contributor.author

Mundis, Gregory M

dc.contributor.author

Fu, Kai-Ming G

dc.contributor.author

Gupta, Munish C

dc.contributor.author

Hostin, Richard

dc.contributor.author

Deviren, Vedat

dc.contributor.author

Kebaish, Khaled

dc.contributor.author

Hart, Robert

dc.contributor.author

Burton, Douglas C

dc.contributor.author

Line, Breton

dc.contributor.author

Bess, Shay

dc.contributor.author

Ames, Christopher P

dc.contributor.author

International Spine Study Group

dc.date.accessioned

2023-07-20T19:51:49Z

dc.date.available

2023-07-20T19:51:49Z

dc.date.issued

2014-12

dc.date.updated

2023-07-20T19:50:25Z

dc.description.abstract

Object

Improved understanding of rod fracture (RF) following adult spinal deformity (ASD) surgery could prove valuable for surgical planning, patient counseling, and implant design. The objective of this study was to prospectively assess the rates of and risk factors for RF following surgery for ASD.

Methods

This was a prospective, multicenter, consecutive series. Inclusion criteria were ASD, age > 18 years, ≥5 levels posterior instrumented fusion, baseline full-length standing spine radiographs, and either development of RF or full-length standing spine radiographs obtained at least 1 year after surgery that demonstrated lack of RF. ASD was defined as presence of at least one of the following: coronal Cobb angle ≥20°, sagittal vertical axis (SVA) ≥5 cm, pelvic tilt (PT) ≥25°, and thoracic kyphosis ≥60°.

Results

Of 287 patients who otherwise met inclusion criteria, 200 (70%) either demonstrated RF or had radiographic imaging obtained at a minimum of 1 year after surgery showing lack of RF. The patients' mean age was 54.8 ± 15.8 years; 81% were women; 10% were smokers; the mean body mass index (BMI) was 27.1 ± 6.5; the mean number of levels fused was 12.0 ± 3.8; and 50 patients (25%) had a pedicle subtraction osteotomy (PSO). The rod material was cobalt chromium (CC) in 53%, stainless steel (SS), in 26%, or titanium alloy (TA) in 21% of cases; the rod diameters were 5.5 mm (in 68% of cases), 6.0 mm (in 13%), or 6.35 mm (in 19%). RF occurred in 18 cases (9.0%) at a mean of 14.7 months (range 3-27 months); patients without RF had a mean follow-up of 19 months (range 12-24 months). Patients with RF were older (62.3 vs 54.1 years, p = 0.036), had greater BMI (30.6 vs 26.7, p = 0.019), had greater baseline sagittal malalignment (SVA 11.8 vs 5.0 cm, p = 0.001; PT 29.1° vs 21.9°, p = 0.016; and pelvic incidence [PI]-lumbar lordosis [LL] mismatch 29.6° vs 12.0°, p = 0.002), and had greater sagittal alignment correction following surgery (SVA reduction by 9.6 vs 2.8 cm, p < 0.001; and PI-LL mismatch reduction by 26.3° vs 10.9°, p = 0.003). RF occurred in 22.0% of patients with PSO (10 of the 11 fractures occurred adjacent to the PSO level), with rates ranging from 10.0% to 31.6% across centers. CC rods were used in 68% of PSO cases, including all with RF. Smoking, levels fused, and rod diameter did not differ significantly between patients with and without RF (p > 0.05). In cases including a PSO, the rate of RF was significantly higher with CC rods than with TA or SS rods (33% vs 0%, p = 0.010). On multivariate analysis, only PSO was associated with RF (p = 0.001, OR 5.76, 95% CI 2.01-15.8).

Conclusions

Rod fracture occurred in 9.0% of ASD patients and in 22.0% of PSO patients with a minimum of 1-year follow-up. With further follow-up these rates would likely be even higher. There was a substantial range in the rate of RF with PSO across centers, suggesting potential variations in technique that warrant future investigation. Due to higher rates of RF with PSO, alternative instrumentation strategies should be considered for these cases.
dc.identifier.issn

1547-5654

dc.identifier.issn

1547-5646

dc.identifier.uri

https://hdl.handle.net/10161/28522

dc.language

eng

dc.publisher

Journal of Neurosurgery Publishing Group (JNSPG)

dc.relation.ispartof

Journal of neurosurgery. Spine

dc.relation.isversionof

10.3171/2014.9.spine131176

dc.subject

International Spine Study Group

dc.subject

Humans

dc.subject

Spinal Diseases

dc.subject

Kyphosis

dc.subject

Postoperative Complications

dc.subject

Prosthesis Failure

dc.subject

Chromium Alloys

dc.subject

Radiography

dc.subject

Spinal Fusion

dc.subject

Osteotomy

dc.subject

Risk Factors

dc.subject

Follow-Up Studies

dc.subject

Prospective Studies

dc.subject

Bone Nails

dc.subject

Adult

dc.subject

Aged

dc.subject

Middle Aged

dc.subject

Female

dc.subject

Male

dc.title

Prospective multicenter assessment of risk factors for rod fracture following surgery for adult spinal deformity.

dc.type

Journal article

duke.contributor.orcid

Shaffrey, Christopher I|0000-0001-9760-8386

pubs.begin-page

994

pubs.end-page

1003

pubs.issue

6

pubs.organisational-group

Duke

pubs.organisational-group

School of Medicine

pubs.organisational-group

Clinical Science Departments

pubs.organisational-group

Orthopaedic Surgery

pubs.organisational-group

Neurosurgery

pubs.publication-status

Published

pubs.volume

21

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Prospective multicenter assessment of risk factors for rod fracture following surgery for adult spinal deformity..pdf
Size:
2.46 MB
Format:
Adobe Portable Document Format