Comparative Risk Assessment of Clinical and Radiation Risk across a Cohort of Patient and Individualized Risk Optimization

dc.contributor.author

Ria, Francesco

dc.contributor.author

Lerebours, Reginald

dc.contributor.author

Zhang, Anru

dc.contributor.author

Erkanli, Alaattin

dc.contributor.author

Abadi, Ehsan

dc.contributor.author

SOLOMON, justin

dc.contributor.author

Marin, daniele

dc.contributor.author

Samei, Ehsan

dc.date.accessioned

2023-09-06T13:42:18Z

dc.date.available

2023-09-06T13:42:18Z

dc.date.issued

2023-07-23

dc.date.updated

2023-09-06T13:42:18Z

dc.description.abstract

Purpose Informed by a recent mathematical framework, we formulated an imaging strategy to balance interpretative performance-based clinical risk (i.e., false positive and false negative rates) and radiation risk as a risk-versus-risk assessment. The model was applied to a population of one million cases simulating a clinical liver cancer scenario. Moreover, a model was developed to predict individualized risk-versus-risk optimization.

Methods The proposed model defined a Total Risk (TR) as the linear combination of radiation risk and clinical risk defined as functions of the radiation burden, the disease prevalence disease, the false positive rate, the expected life-expectancy loss for an incorrect diagnosis, and the radiologist interpretative performance (i.e., AUC). The mathematical framework was applied to a simulated dataset of 1,000,000 CT studies investigating localized stage liver cancer assuming a typical false positive rate of 5% and optimal imaging conditions (AUC=0.75). Demographic information was simulated according with literature and census data including male and female for different patient races (white, black, Asian, and Hispanic). Following BEIR-VII report, organ-specific radiation doses were used to calculate the radiation Risk Index per each patient. The model was then extended to predict the optimal scanner output associated with the TR for specific patients.

Results Across all races and sexes, median radiation risk ranged between 0.008 and 0.012 number of deaths per 100 patients; median clinical risk ranged between 0.042 and 0.076; and medial total risk ranged between 0.010 and 0.088 deaths per 100 patients. The mathematical model was then generalized to estimate individualized optimal imaging condition minimizing TR.

Conclusion A mathematical framework to describe total risk in CT was robustly tested in a simulated dataset of 1,000,000 CT studies. The results highlighted the dominance of clinical risk at typical CT examination dose levels. The generalization of the mathematical model allowed the prediction of individualized risk optimization.

dc.identifier.issn

0094-2405

dc.identifier.issn

2473-4209

dc.identifier.uri

https://hdl.handle.net/10161/28973

dc.publisher

Wiley

dc.relation.ispartof

https://aapm.onlinelibrary.wiley.com/doi/epdf/10.1002/mp.16525

dc.relation.isversionof

10.1002/mp.16525

dc.title

Comparative Risk Assessment of Clinical and Radiation Risk across a Cohort of Patient and Individualized Risk Optimization

dc.type

Conference

duke.contributor.orcid

Ria, Francesco|0000-0001-5902-7396

duke.contributor.orcid

Erkanli, Alaattin|0000-0002-5437-4900

duke.contributor.orcid

Abadi, Ehsan|0000-0002-9123-5854

duke.contributor.orcid

Samei, Ehsan|0000-0001-7451-3309

pubs.begin-page

E117

pubs.end-page

E177

pubs.issue

6

pubs.organisational-group

Duke

pubs.organisational-group

School of Medicine

pubs.organisational-group

Clinical Science Departments

pubs.organisational-group

Radiology

pubs.publication-status

Published

pubs.volume

50

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
AAPM_2023_CT_risk_simulations_absrtact._ria.pdf
Size:
81.09 KB
Format:
Adobe Portable Document Format
Description:
Published version