Validation of Algorithmic CT Image Quality Metrics with Preferences of Radiologists.

dc.contributor.author

Cheng, Yuan

dc.contributor.author

Abadi, Ehsan

dc.contributor.author

Smith, Taylor Brunton

dc.contributor.author

Ria, Francesco

dc.contributor.author

Meyer, Mathias

dc.contributor.author

Marin, Daniele

dc.contributor.author

Samei, Ehsan

dc.date.accessioned

2019-09-17T15:08:45Z

dc.date.available

2019-09-17T15:08:45Z

dc.date.issued

2019-08-29

dc.date.updated

2019-09-17T15:08:45Z

dc.description.abstract

PURPOSE:Automated assessment of perceptual image quality on clinical Computed Tomography (CT) data by computer algorithms has the potential to greatly facilitate data-driven monitoring and optimization of CT image acquisition protocols. The application of these techniques in clinical operation requires the knowledge of how the output of the computer algorithms corresponds to clinical expectations. This study addressed the need to validate algorithmic image quality measurements on clinical CT images with preferences of radiologists and determine the clinically acceptable range of algorithmic measurements for abdominal CT examinations. MATERIALS AND METHODS:Algorithmic measurements of image quality metrics (organ HU, noise magnitude, and clarity) were performed on a clinical CT image dataset with supplemental measures of noise power spectrum from phantom images using techniques developed previously. The algorithmic measurements were compared to clinical expectations of image quality in an observer study with seven radiologists. Sets of CT liver images were selected from the dataset where images in the same set varied in terms of one metric at a time. These sets of images were shown via a web interface to one observer at a time. First, the observer rank ordered the CT images in a set according to his/her preference for the varying metric. The observer then selected his/her preferred acceptable range of the metric within the ranked images. The agreement between algorithmic and observer rankings of image quality were investigated and the clinically acceptable image quality in terms of algorithmic measurements were determined. RESULTS:The overall rank order agreements between algorithmic and observer assessments were 0.90, 0.98, and 1.00 for noise magnitude, liver parenchyma HU, and clarity, respectively. The results indicate a strong agreement between the algorithmic and observer assessments of image quality. Clinically acceptable thresholds (median) of algorithmic metric values were (17.8, 32.6) HU for noise magnitude, (92.1, 131.9) for liver parenchyma HU, and (0.47, 0.52) for clarity. CONCLUSIONS:The observer study results indicated that these algorithms can robustly assess the perceptual quality of clinical CT images in an automated fashion. Clinically acceptable ranges of algorithmic measurements were determined. The correspondence of these image quality assessment algorithms to clinical expectations paves the way towards establishing diagnostic reference levels in terms of clinically acceptable perceptual image quality and data-driven optimization of CT image acquisition protocols.

dc.identifier.issn

0094-2405

dc.identifier.issn

2473-4209

dc.identifier.uri

https://hdl.handle.net/10161/19317

dc.language

eng

dc.publisher

Wiley

dc.relation.ispartof

Medical physics

dc.relation.isversionof

10.1002/mp.13795

dc.title

Validation of Algorithmic CT Image Quality Metrics with Preferences of Radiologists.

dc.type

Journal article

duke.contributor.orcid

Abadi, Ehsan|0000-0002-9123-5854

duke.contributor.orcid

Samei, Ehsan|0000-0001-7451-3309

pubs.organisational-group

Staff

pubs.organisational-group

Duke

pubs.organisational-group

Radiology

pubs.organisational-group

Clinical Science Departments

pubs.organisational-group

School of Medicine

pubs.publication-status

Published