Validating an Autoclave Cycle for Sterilization of Select Agent-Infected Murine Carcasses

dc.contributor.author

Condreay, J Patrick

dc.contributor.author

Riebe, Kristina

dc.contributor.author

Asrican, Rose

dc.contributor.author

Alderman, Scott

dc.date.accessioned

2026-03-30T14:02:40Z

dc.date.available

2026-03-30T14:02:40Z

dc.description.abstract

<jats:sec> <jats:title>Introduction:</jats:title> <jats:p>Infectious disease research conducted in the Duke Regional Biocontainment Laboratory, a biosafety level-3 facility, often includes work with mice. Infected carcasses must be properly decontaminated at the completion of each study and prior to removal from the facility. Working with Select Agents requires validated methods for complete inactivation of the agent before carcasses can be removed from registered spaces.</jats:p> </jats:sec> <jats:sec> <jats:title>Methods:</jats:title> <jats:p>Biological indicators were implanted into the abdomen of unfrozen mouse carcasses, then autoclaved using different cycle parameters and packaging strategies to determine the best approach to ensure complete sterilization.</jats:p> </jats:sec> <jats:sec> <jats:title>Results:</jats:title> <jats:p>Both 20-min and 30-min autoclave cycles at 122°C, with three pre-vacuum pulses, failed to consistently sterilize unfrozen mouse carcasses. A 45-min autoclave cycle with the same parameters did result in the successful sterilization of carcasses when packaged at two or four carcasses in an 8” × 12” autoclave bag.</jats:p> </jats:sec> <jats:sec> <jats:title>Conclusions:</jats:title> <jats:p>This study supports the utilization of an autoclave cycle (122°C sterilization temperature, 45-min sterilization time, three pre-vacuum pulses) to sterilize unfrozen mouse carcasses, up to four per bag.</jats:p> </jats:sec>

dc.identifier.issn

1535-6760

dc.identifier.issn

2470-1246

dc.identifier.uri

https://hdl.handle.net/10161/34334

dc.language

en

dc.publisher

SAGE Publications

dc.relation.ispartof

Applied Biosafety

dc.relation.isversionof

10.1177/15356760261433036

dc.rights.uri

https://creativecommons.org/licenses/by-nc/4.0

dc.title

Validating an Autoclave Cycle for Sterilization of Select Agent-Infected Murine Carcasses

dc.type

Journal article

pubs.organisational-group

Duke

pubs.organisational-group

School of Medicine

pubs.organisational-group

Staff

pubs.organisational-group

Clinical Science Departments

pubs.organisational-group

Medicine

pubs.organisational-group

Medicine, Duke Human Vaccine Institute

pubs.publication-status

Published online

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
condreay-et-al-2026-validating-an-autoclave-cycle-for-sterilization-of-select-agent-infected-murine-carcasses.pdf
Size:
698.23 KB
Format:
Adobe Portable Document Format