Adaptive stereotactic body radiation therapy planning for lung cancer.

dc.contributor.advisor

Cai, Jing

dc.contributor.author

Qin, Y

dc.contributor.author

Zhang, F

dc.contributor.author

Yoo, DS

dc.contributor.author

Kelsey, CR

dc.contributor.author

Yin, FF

dc.contributor.author

Cai, J

dc.date.accessioned

2013-05-13T15:37:33Z

dc.date.issued

2013-09-01

dc.department

Medical Physics

dc.description.abstract

PURPOSE: To investigate the dosimetric effects of adaptive planning on lung stereotactic body radiation therapy (SBRT). METHODS AND MATERIALS: Forty of 66 consecutive lung SBRT patients were selected for a retrospective adaptive planning study. CBCT images acquired at each fraction were used for treatment planning. Adaptive plans were created using the same planning parameters as the original CT-based plan, with the goal to achieve comparable comformality index (CI). For each patient, 2 cumulative plans, nonadaptive plan (PNON) and adaptive plan (PADP), were generated and compared for the following organs-at-risks (OARs): cord, esophagus, chest wall, and the lungs. Dosimetric comparison was performed between PNON and PADP for all 40 patients. Correlations were evaluated between changes in dosimetric metrics induced by adaptive planning and potential impacting factors, including tumor-to-OAR distances (dT-OAR), initial internal target volume (ITV1), ITV change (ΔITV), and effective ITV diameter change (ΔdITV). RESULTS: 34 (85%) patients showed ITV decrease and 6 (15%) patients showed ITV increase throughout the course of lung SBRT. Percentage ITV change ranged from -59.6% to 13.0%, with a mean (±SD) of -21.0% (±21.4%). On average of all patients, PADP resulted in significantly (P=0 to .045) lower values for all dosimetric metrics. ΔdITV/dT-OAR was found to correlate with changes in dose to 5 cc (ΔD5cc) of esophagus (r=0.61) and dose to 30 cc (ΔD30cc) of chest wall (r=0.81). Stronger correlations between ΔdITV/dT-OAR and ΔD30cc of chest wall were discovered for peripheral (r=0.81) and central (r=0.84) tumors, respectively. CONCLUSIONS: Dosimetric effects of adaptive lung SBRT planning depend upon target volume changes and tumor-to-OAR distances. Adaptive lung SBRT can potentially reduce dose to adjacent OARs if patients present large tumor volume shrinkage during the treatment.

dc.identifier.uri

https://hdl.handle.net/10161/7295

dc.relation.ispartof

Int J Radiat Oncol Biol Phys

dc.relation.isversionof

10.1016/j.ijrobp.2013.05.008

dc.subject

Adult

dc.subject

Aged

dc.subject

Aged, 80 and over

dc.subject

Cone-Beam Computed Tomography

dc.subject

Dose Fractionation

dc.subject

Esophagus

dc.subject

Female

dc.subject

Humans

dc.subject

Lung

dc.subject

Lung Neoplasms

dc.subject

Male

dc.subject

Middle Aged

dc.subject

Organs at Risk

dc.subject

Radiosurgery

dc.subject

Radiotherapy Planning, Computer-Assisted

dc.subject

Retrospective Studies

dc.subject

Spinal cord

dc.subject

Thoracic Wall

dc.subject

Tumor Burden

dc.title

Adaptive stereotactic body radiation therapy planning for lung cancer.

dc.type

Master's thesis

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Qin_duke_0066N_11887.pdf
Size:
1.12 MB
Format:
Adobe Portable Document Format

Collections