Technical Note: Validation of TG 233 phantom methodology to characterize noise and dose in patient CT data.

dc.contributor.author

Ria, Francesco

dc.contributor.author

Solomon, Justin

dc.contributor.author

Wilson, Joshua M

dc.contributor.author

Samei, Ehsan

dc.date.accessioned

2020-02-12T15:54:47Z

dc.date.available

2020-02-12T15:54:47Z

dc.date.issued

2020-02-10

dc.date.updated

2020-02-12T15:54:45Z

dc.description.abstract

PURPOSE: Phantoms are useful tools in diagnostic CT, but practical limitations reduce phantoms to being only a limited patient surrogate. Furthermore, a phantom with a single cross sectional area cannot be used to evaluate scanner performance in modern CT scanners that use dose reduction techniques such as Automated Tube Current Modulation (ATCM) and Iterative Reconstruction (IR) algorithms to adapt x-ray flux to patient size, reduce radiation dose, and achieve uniform image noise. A new multi-sized phantom (Mercury Phantom, MP) has been introduced, representing multiple diameters. This work aimed to ascertain if measurements from MP can predict radiation dose and image noise in clinical CT images to prospectively inform protocol design. METHODS: The adult MP design included four different physical diameters (18.5, 23.0, 30.0, 37.0 cm) representing a range of patient sizes. The study included 1457 examinations performed on two scanner models from two vendors, and two clinical protocols (abdominopelvic with and chest without contrast). Attenuating diameter, radiation dose, and noise magnitude (average pixel standard deviation in uniform image) was automatically estimated in patients and in the MP using a previously validated algorithm. An exponential fit of CTDIvol and noise as a function of size was applied to patients and MP data. Lastly, the fit equations from the phantom data were used to fit the patient data. In each patient distribution fit, the normalized root mean square error (nRMSE) values were calculated in the residuals' plots as a metric to indicate how well the phantom data can predict dose and noise in clinical operations as a function of size. RESULTS: For dose across patient size distributions, the difference between nRMSE from patient fit and MP model data prediction ranged between 0.6% and 2.0% (mean 1.2%). For noise across patient size distributions, the nRMSE difference ranged between 0.1% and 4.7% (mean 1.4%). CONCLUSION: The Mercury Phantom provided a close prediction of radiation dose and image noise in clinical patient images. By assessing dose and image quality in a phantom with multiple sizes, protocol parameters can be designed and optimized per patient size in a highly constrained setup to predict clinical scanner and ATCM system performance.

dc.identifier.issn

2473-4209

dc.identifier.uri

https://hdl.handle.net/10161/20154

dc.language

eng

dc.publisher

Wiley

dc.relation.ispartof

Med Phys

dc.relation.isversionof

10.1002/mp.14089

dc.subject

dose prediction

dc.subject

multi-sized phantom

dc.subject

noise prediction

dc.subject

prospective protocol design

dc.title

Technical Note: Validation of TG 233 phantom methodology to characterize noise and dose in patient CT data.

dc.type

Journal article

duke.contributor.orcid

Ria, Francesco|0000-0001-5902-7396

duke.contributor.orcid

Wilson, Joshua M|0000-0002-4175-6301

duke.contributor.orcid

Samei, Ehsan|0000-0001-7451-3309

pubs.organisational-group

Staff

pubs.organisational-group

Radiology

pubs.organisational-group

Duke

pubs.organisational-group

Clinical Science Departments

pubs.organisational-group

School of Medicine

pubs.publication-status

Published online

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Ria_et_al-2020-Medical_Physics.pdf
Size:
10.28 MB
Format:
Adobe Portable Document Format