Efficacy of ELP as an Intratumoral Depot for Radionuclide Therapy of PC-3 Prostate Cancer in an Orthotopic, Nude Mouse Model
Date
2012
Authors
Advisors
Journal Title
Journal ISSN
Volume Title
Repository Usage Stats
views
downloads
Abstract
Brachytherapy has emerged as one of the pre-eminent radiotherapy modalities for the treatment of prostate cancer. Current clinical methods utilize titanium encased radioactive seeds that are fixated within the prostate and permanently implanted. A novel brachytherapy alternative that has been developed to improve the delivery of radionuclide intratumorally is the synthetically designed elastin-like polypeptide (ELP). ELP can be injected in fluid form and undergoes an inverse phase transition to a biocompatible coascervate capable of serving as a biocompatible, intratumoral depot. Utilizing a previously developed ELP with a 7 tyrosine C-terminus tail, the therapeutic efficacy of ELP as a radioactive depot for treating prostate cancer was examined in a preclinical, orthotopic model. The orthotopic prostate model was first established by xenografting Bioware® PC-3M-luc-C6 cells into immunoincompetent, Balb/c nude mice. A non-invasive method for tracking tumor progression in vivo was developed using a correlation model comparing quantitative luminescent flux emitted from the cell line against the actual tumor size. The correlation between flux and tumor volume was determined to as Volume = 7.234x10-9x - 18.54, (±21.7%), where x is the supine photon flux measured from a 10 second exposure taken 18 minutes after D-luciferin injection. Radionuclide conjugation of 131I to ELP was conducted using the established IODO-GEN reaction methodology and mice were administered a therapeutic dose of 2mCi / 40µl ELP / 150 mm3 prostate tumor. Intratumoral deposition resulted in tumor regression in 90.9% of treated mice (n=11); 63.6% of which achieved tumor size reduction by over 60%. Radioactivity measurements demonstrate an 89.9% ELP depot retention over 2 weeks. Survival rates of the test group (64%) compared with controls (100%, n=14) indicate further testing is required to optimize radionuclide dosimetry.
Type
Department
Description
Provenance
Citation
Permalink
Citation
Schaal, Jeffrey Laurence (2012). Efficacy of ELP as an Intratumoral Depot for Radionuclide Therapy of PC-3 Prostate Cancer in an Orthotopic, Nude Mouse Model. Master's thesis, Duke University. Retrieved from https://hdl.handle.net/10161/5534.
Collections
Except where otherwise noted, student scholarship that was shared on DukeSpace after 2009 is made available to the public under a Creative Commons Attribution / Non-commercial / No derivatives (CC-BY-NC-ND) license. All rights in student work shared on DukeSpace before 2009 remain with the author and/or their designee, whose permission may be required for reuse.