Expansion of the 4D XCAT Phantom Library with Anatomical Texture

dc.contributor.advisor

Samei, Ehsan

dc.contributor.author

Bond, Jason

dc.date.accessioned

2013-11-14T19:16:22Z

dc.date.available

2013-11-14T19:16:22Z

dc.date.issued

2013

dc.department

Medical Physics

dc.description.abstract

Computational phantoms are set to play an important role in imaging research. As medicine moves increasingly towards providing individualized, patient-specific care, it is imperative that simulations be completed on patient-specific anatomy, rather than a reference standard. To that end, there is need for a variety of realistic phantoms for clinical studies.

This work adds to the existing extended cardiac and torso (XCAT) adult phantom series (two phantoms based on visual human data) by building new models based on adult patient computed tomography (CT) image data. These CT datasets were obtained from Duke University's patient CT database.

Each image-set was segmented using in-house segmentation software, defining bony structures and large organs within the field of view. 3D non-uniform rational b-spline (NURBS) surfaces were fitted to the segmented data. Using the multi-channel large diffeomorphic deformation metric mapping (MC-LDDMM) network, a transform was calculated to morph an existing XCAT model to the segmented patient geometry. Fifty-eight adult XCAT models were added to the phantom library.

In addition to the expanding the XCAT library, the feasibility of incorporating texture was investigated. Currently, the XCAT phantom structures are assumed to be homogeneous. This can lead to unrealistic appearance when the phantoms are combined with imaging simulations, particularly in CT. The purpose of this project was to capture anatomical texture and test it in a simulated phantom. Image data from the aforementioned patient CT database served as the source of anatomical texture.

The images were de-noised using anisotropic diffusion. Next, several regions of interest (ROIs) were taken from the liver and lungs of CT images. Using the ROIs as a source of texture, a larger stochastic texture image-set was created using the Image Quilting algorithm.

The visual human adult male XCAT phantom was voxelized at the same resolution as the texture image. The voxels inside the liver were directly replaced by the corresponding voxels of texture. Similarly for the lung, the voxels between the existing lung bronchi/blood vessels and the lung wall were replaced by texture voxels. This procedure was performed using ten different patient CT image-sets as sources of texture.

To validate the similarity of the artificial textures to the source textures, reconstructions of the adult male XCAT phantom with added textures were compared to the clinical images via receiver operator characteristic (ROC) analysis, a two-sample t-test, equivalence test, and through comparing absolute differences between scores.

It was concluded that this framework provides a valuable tool in which anatomical texture can be incorporated into computational phantoms. It is anticipated that this step towards making many anatomically variable virtual models indicative of a patient populace and making these models more realistic will be useful in medical imaging research, especially for studies relating to image quality.

dc.identifier.uri

https://hdl.handle.net/10161/8094

dc.subject

Medical imaging and radiology

dc.subject

Computerized phantoms

dc.subject

CT

dc.subject

Simulation

dc.subject

Texture synthesis

dc.subject

XCAT

dc.title