A neural network-based method for spectral distortion correction in photon counting x-ray CT.

dc.contributor.author

Touch, Mengheng

dc.contributor.author

Clark, Darin P

dc.contributor.author

Barber, William

dc.contributor.author

Badea, Cristian T

dc.date.accessioned

2018-04-14T11:07:23Z

dc.date.available

2018-04-14T11:07:23Z

dc.date.issued

2016-08

dc.date.updated

2018-04-14T11:07:22Z

dc.description.abstract

Spectral CT using a photon counting x-ray detector (PCXD) shows great potential for measuring material composition based on energy dependent x-ray attenuation. Spectral CT is especially suited for imaging with K-edge contrast agents to address the otherwise limited contrast in soft tissues. We have developed a micro-CT system based on a PCXD. This system enables both 4 energy bins acquisition, as well as full-spectrum mode in which the energy thresholds of the PCXD are swept to sample the full energy spectrum for each detector element and projection angle. Measurements provided by the PCXD, however, are distorted due to undesirable physical effects in the detector and can be very noisy due to photon starvation in narrow energy bins. To address spectral distortions, we propose and demonstrate a novel artificial neural network (ANN)-based spectral distortion correction mechanism, which learns to undo the distortion in spectral CT, resulting in improved material decomposition accuracy. To address noise, post-reconstruction denoising based on bilateral filtration, which jointly enforces intensity gradient sparsity between spectral samples, is used to further improve the robustness of ANN training and material decomposition accuracy. Our ANN-based distortion correction method is calibrated using 3D-printed phantoms and a model of our spectral CT system. To enable realistic simulations and validation of our method, we first modeled the spectral distortions using experimental data acquired from (109)Cd and (133)Ba radioactive sources measured with our PCXD. Next, we trained an ANN to learn the relationship between the distorted spectral CT projections and the ideal, distortion-free projections in a calibration step. This required knowledge of the ground truth, distortion-free spectral CT projections, which were obtained by simulating a spectral CT scan of the digital version of a 3D-printed phantom. Once the training was completed, the trained ANN was used to perform distortion correction on any subsequent scans of the same system with the same parameters. We used joint bilateral filtration to perform noise reduction by jointly enforcing intensity gradient sparsity between the reconstructed images for each energy bin. Following reconstruction and denoising, the CT data was spectrally decomposed using the photoelectric effect, Compton scattering, and a K-edge material (i.e. iodine). The ANN-based distortion correction approach was tested using both simulations and experimental data acquired in phantoms and a mouse with our PCXD-based micro-CT system for 4 bins and full-spectrum acquisition modes. The iodine detectability and decomposition accuracy were assessed using the contrast-to-noise ratio and relative error in iodine concentration estimation metrics in images with and without distortion correction. In simulation, the material decomposition accuracy in the reconstructed data was vastly improved following distortion correction and denoising, with 50% and 20% reductions in material concentration measurement error in full-spectrum and 4 energy bins cases, respectively. Overall, experimental data confirms that full-spectrum mode provides superior results to 4-energy mode when the distortion corrections are applied. The material decomposition accuracy in the reconstructed data was vastly improved following distortion correction and denoising, with as much as a 41% reduction in material concentration measurement error for full-spectrum mode, while also bringing the iodine detectability to 4-6 mg ml(-1). Distortion correction also improved the 4 bins mode data, but to a lesser extent. The results demonstrate the experimental feasibility and potential advantages of ANN-based distortion correction and joint bilateral filtration-based denoising for accurate K-edge imaging with a PCXD. Given the computational efficiency with which the ANN can be applied to projection data, the proposed scheme can be readily integrated into existing CT reconstruction pipelines.

dc.identifier.issn

0031-9155

dc.identifier.issn

1361-6560

dc.identifier.uri

https://hdl.handle.net/10161/16500

dc.language

eng

dc.publisher

IOP Publishing

dc.relation.ispartof

Physics in medicine and biology

dc.relation.isversionof

10.1088/0031-9155/61/16/6132

dc.subject

Animals

dc.subject

Mice, Inbred C57BL

dc.subject

Mice

dc.subject

Radiographic Image Interpretation, Computer-Assisted

dc.subject

Tomography, X-Ray Computed

dc.subject

Artifacts

dc.subject

Phantoms, Imaging

dc.subject

Algorithms

dc.subject

Neural Networks (Computer)

dc.subject

Photons

dc.title

A neural network-based method for spectral distortion correction in photon counting x-ray CT.

dc.type

Journal article

duke.contributor.orcid

Badea, Cristian T|0000-0002-1850-2522

pubs.issue

16

pubs.organisational-group

School of Medicine

pubs.organisational-group

Duke

pubs.organisational-group

Duke Cancer Institute

pubs.organisational-group

Institutes and Centers

pubs.organisational-group

Radiology

pubs.organisational-group

Clinical Science Departments

pubs.publication-status

Published

pubs.volume

61

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Ashton_EXIA-cmmi2014.pdf
Size:
1.51 MB
Format:
Adobe Portable Document Format