dc.description.abstract

<jats:p>Due to the concerns about radiation dose associated with medical imaging, radiation dose monitoring systems (RDMSs) are now utilized by many radiology providers to collect, process, analyze, and manage radiation dose-related information. Currently, most commercially available RDMSs focus only on radiation dose information and do not track any metrics related to image quality. However, to enable comprehensive patient-based imaging optimization, it is equally important to monitor image quality as well. This article describes how RDMS design can be extended beyond radiation dose to simultaneously monitor image quality. A newly designed interface was evaluated by different groups of radiology professionals (radiologists, technologists, and physicists) on a Likert scale. The results show that the new design is effective in assessing both image quality and safety in clinical practices, with an overall average score of 7.8 out of 10.0 and scores ranging from 5.5 to 10.0. Radiologists rated the interface highest at 8.4 out of 10.0, followed by technologists at 7.6 out of 10.0, and medical physicists at 7.5 out of 10.0. This work demonstrates how the assessment of the radiation dose can be performed in conjunction with the image quality using customizable user interfaces based on the clinical needs associated with different radiology professions.</jats:p>

dc.identifier.issn

2379-139X

dc.identifier.uri

https://hdl.handle.net/10161/27064

dc.language

en

dc.publisher

MDPI AG

dc.relation.ispartof

Tomography

dc.relation.isversionof

10.3390/tomography9020065

dc.title

Making CT Dose Monitoring Meaningful: Augmenting Dose with Imaging Quality

dc.type

Journal article

duke.contributor.orcid

Ria, Francesco|0000-0001-5902-7396

duke.contributor.orcid

Ding, Aiping|0000-0002-6971-7283

duke.contributor.orcid

Samei, Ehsan|0000-0001-7451-3309

pubs.begin-page

798

pubs.end-page

809

pubs.issue

2

pubs.organisational-group

Duke

pubs.organisational-group

School of Medicine

pubs.organisational-group

Staff

pubs.organisational-group

Clinical Science Departments

pubs.organisational-group

Radiology

pubs.publication-status

Published online

pubs.volume

9

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
CT_dose_monitoring_meaningful_Alsaihati_et_al_2023_Tomography.pdf
Size:
2.76 MB
Format:
Adobe Portable Document Format
Description:
Published version