CT Scan Dosimetric Parameters Routine Monitoring: First Results of Radiation Dose Optimization Strategies Promptly Provided by a Multidisciplinary Team

dc.contributor.author

Ria, F

dc.contributor.author

Bergantin, A

dc.contributor.author

Redaelli, I

dc.contributor.author

Invernizzi, M

dc.contributor.author

Vai, A

dc.contributor.author

Fazzini, D

dc.contributor.author

Gozzi, G

dc.contributor.author

Papa, S

dc.coverage.spatial

Chicago

dc.date.accessioned

2016-04-15T17:03:28Z

dc.date.issued

2015-11-29

dc.description.abstract

CONCLUSION Radiation dose reduction, while saving image quality could be easily implemented with this approach. Furthermore, the availability of a dosimetric data archive provides immediate feedbacks, related to the implemented optimization strategies. Background JCI Standards and European Legislation (EURATOM 59/2013) require the implementation of patient radiation protection programs in diagnostic radiology. Aim of this study is to demonstrate the possibility to reduce patients radiation exposure without decreasing image quality, through a multidisciplinary team (MT), which analyzes dosimetric data of diagnostic examinations. Evaluation Data from CT examinations performed with two different scanners (Siemens DefinitionTM and GE LightSpeed UltraTM) between November and December 2013 are considered. CT scanners are configured to automatically send images to DoseWatch© software, which is able to store output parameters (e.g. kVp, mAs, pitch ) and exposure data (e.g. CTDIvol, DLP, SSDE). Data are analyzed and discussed by a MT composed by Medical Physicists and Radiologists, to identify protocols which show critical dosimetric values, then suggest possible improvement actions to be implemented. Furthermore, the large amount of data available allows to monitor diagnostic protocols currently in use and to identify different statistic populations for each of them. Discussion We identified critical values of average CTDIvol for head and facial bones examinations (respectively 61.8 mGy, 151 scans; 61.6 mGy, 72 scans), performed with the GE LightSpeed CTTM. Statistic analysis allowed us to identify the presence of two different populations for head scan, one of which was only 10% of the total number of scans and corresponded to lower exposure values. The MT adopted this protocol as standard. Moreover, the constant output parameters monitoring allowed us to identify unusual values in facial bones exams, due to changes during maintenance service, which the team promptly suggested to correct. This resulted in a substantial dose saving in CTDIvol average values of approximately 15% and 50% for head and facial bones exams, respectively. Diagnostic image quality was deemed suitable for clinical use by radiologists.

dc.identifier.uri

https://hdl.handle.net/10161/11819

dc.source

RSNA 2015

dc.title

CT Scan Dosimetric Parameters Routine Monitoring: First Results of Radiation Dose Optimization Strategies Promptly Provided by a Multidisciplinary Team

dc.type

Conference

duke.contributor.orcid

Ria, F|0000-0001-5902-7396

pubs.author-url

http://archive.rsna.org/2015/15047654.html

pubs.finish-date

2015-12-04

pubs.organisational-group

Clinical Science Departments

pubs.organisational-group

Duke

pubs.organisational-group

Radiology

pubs.organisational-group

School of Medicine

pubs.start-date

2015-11-29

Files

Original bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
abstract.pdf
Size:
28.53 KB
Format:
Unknown data format
Description:
Accepted version