Optical-CT 3D Dosimetry Using Fresnel Lenses with Minimal Refractive-Index Matching Fluid.

dc.contributor.author

Bache, Steven

dc.contributor.author

Malcolm, Javian

dc.contributor.author

Adamovics, John

dc.contributor.author

Oldham, Mark

dc.contributor.editor

Zhang, Qinghui

dc.coverage.spatial

United States

dc.date.accessioned

2016-05-13T12:54:49Z

dc.date.issued

2016

dc.description.abstract

Telecentric optical computed tomography (optical-CT) is a state-of-the-art method for visualizing and quantifying 3-dimensional dose distributions in radiochromic dosimeters. In this work a prototype telecentric system (DFOS-Duke Fresnel Optical-CT Scanner) is evaluated which incorporates two substantial design changes: the use of Fresnel lenses (reducing lens costs from $10-30K t0 $1-3K) and the use of a 'solid tank' (which reduces noise, and the volume of refractively matched fluid from 1 ltr to 10 cc). The efficacy of DFOS was evaluated by direct comparison against commissioned scanners in our lab. Measured dose distributions from all systems were compared against the predicted dose distributions from a commissioned treatment planning system (TPS). Three treatment plans were investigated including a simple four-field box treatment, a multiple small field delivery, and a complex IMRT treatment. Dosimeters were imaged within 2 h post irradiation, using consistent scanning techniques (360 projections acquired at 1 degree intervals, reconstruction at 2mm). DFOS efficacy was evaluated through inspection of dose line-profiles, and 2D and 3D dose and gamma maps. DFOS/TPS gamma pass rates with 3%/3mm dose difference/distance-to-agreement criteria ranged from 89.3% to 92.2%, compared to from 95.6% to 99.0% obtained with the commissioned system. The 3D gamma pass rate between the commissioned system and DFOS was 98.2%. The typical noise rates in DFOS reconstructions were up to 3%, compared to under 2% for the commissioned system. In conclusion, while the introduction of a solid tank proved advantageous with regards to cost and convenience, further work is required to improve the image quality and dose reconstruction accuracy of the new DFOS optical-CT system.

dc.identifier

http://www.ncbi.nlm.nih.gov/pubmed/27019460

dc.identifier

PONE-D-15-39049

dc.identifier.eissn

1932-6203

dc.identifier.uri

https://hdl.handle.net/10161/12017

dc.language

eng

dc.publisher

Public Library of Science (PLoS)

dc.relation.ispartof

PLoS One

dc.relation.isversionof

10.1371/journal.pone.0152606

dc.subject

Artifacts

dc.subject

Dose-Response Relationship, Radiation

dc.subject

Gamma Rays

dc.subject

Imaging, Three-Dimensional

dc.subject

Lenses

dc.subject

Radiometry

dc.subject

Refractometry

dc.subject

Solutions

dc.subject

Tomography, X-Ray Computed

dc.title

Optical-CT 3D Dosimetry Using Fresnel Lenses with Minimal Refractive-Index Matching Fluid.

dc.type

Journal article

pubs.author-url

http://www.ncbi.nlm.nih.gov/pubmed/27019460

pubs.begin-page

e0152606

pubs.issue

3

pubs.organisational-group

Clinical Science Departments

pubs.organisational-group

Duke

pubs.organisational-group

Duke Cancer Institute

pubs.organisational-group

Institutes and Centers

pubs.organisational-group

Radiation Oncology

pubs.organisational-group

School of Medicine

pubs.publication-status

Published online

pubs.volume

11

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Optical-CT 3D Dosimetry Using Fresnel Lenses with Minimal Refractive-Index Matching Fluid.pdf
Size:
3.69 MB
Format:
Adobe Portable Document Format