Assessment of a Handheld Near-Infrared Spectroscopy Device in Detecting Traumatic Intracranial Hemorrhage in Uganda

Loading...

Date

2025

Journal Title

Journal ISSN

Volume Title

Repository Usage Stats

18
views
3
downloads

Attention Stats

Abstract

AbstractBackground: Traumatic brain injury (TBI) is a leading cause of morbidity and mortality worldwide, particularly in low- and middle-income countries (LMICs) like Uganda, where the burden is disproportionately high due to factors such as the prevalence of motorcycle accidents and the limited neurosurgical resources. Computed tomography (CT) scans are essential to TBI care, though a limited resource in LMICs. This study aims to assess the diagnostic accuracy of the handheld near infrared device (NIRD), Infrascanner 2500™, in identifying traumatic intracranial hemorrhage in Uganda. The study will evaluate the device's sensitivity, specificity, and predictive values against CT scans in neurotrauma patients. Methods: Patients with suspected head trauma at Mbarara Regional Referral Hospital (MRRH) and Mayanja Memorial Hospital (MMH) who received a head CT scan were included. Participants were scanned with the Infrascanner 2500™ within 30 minutes after their head CT scan. Participant demographics, presenting characteristics, and Infrascanner 2500™ output were recorded. Results: Of the 137 participants included in this interim analysis, 62 (45%) were positive for intracranial hematoma. The Infrascanner 2500™ showed a sensitivity of 83.9% and a specificity of 25.3%. The positive predictive value and negative predictive value were 48.1% and 65.5% respectively. Results showed a high false positive rate across the cohort. Conclusion: This study demonstrated the Infrascanner 2500TM with low specificity and sufficient specificity for detecting intracranial bleeds for patients with TBI in Uganda. The refinement of NIR devices and continued investigation into factors affecting the Infrascanner 2500TM diagnostic performance will be essential to its potential for improving TBI management.

Department

Description

Provenance

Subjects

Neurosciences, global neurosurgery, LMIC, near-infrared device, TBI, traumatic brain injury, Uganda

Citation

Citation

Trillo Ordonez, Yesel (2025). Assessment of a Handheld Near-Infrared Spectroscopy Device in Detecting Traumatic Intracranial Hemorrhage in Uganda. Master's thesis, Duke University. Retrieved from https://hdl.handle.net/10161/32883.

Collections


Except where otherwise noted, student scholarship that was shared on DukeSpace after 2009 is made available to the public under a Creative Commons Attribution / Non-commercial / No derivatives (CC-BY-NC-ND) license. All rights in student work shared on DukeSpace before 2009 remain with the author and/or their designee, whose permission may be required for reuse.