Rapid ratiometric determination of hemoglobin concentration using UV-VIS diffuse reflectance at isosbestic wavelengths.

dc.contributor.author

Phelps, Janelle E

dc.contributor.author

Vishwanath, Karthik

dc.contributor.author

Chang, Vivide TC

dc.contributor.author

Ramanujam, Nirmala

dc.coverage.spatial

United States

dc.date.accessioned

2011-06-21T17:27:44Z

dc.date.issued

2010-08-30

dc.description.abstract

We developed a ratiometric method capable of estimating total hemoglobin concentration from optically measured diffuse reflectance spectra. The three isosbestic wavelength ratio pairs that best correlated to total hemoglobin concentration independent of saturation and scattering were 545/390, 452/390, and 529/390 nm. These wavelength pairs were selected using forward Monte Carlo simulations which were used to extract hemoglobin concentration from experimental phantom measurements. Linear regression coefficients from the simulated data were directly applied to the phantom data, by calibrating for instrument throughput using a single phantom. Phantoms with variable scattering and hemoglobin saturation were tested with two different instruments, and the average percent errors between the expected and ratiometrically-extracted hemoglobin concentration were as low as 6.3%. A correlation of r = 0.88 between hemoglobin concentration extracted using the 529/390 nm isosbestic ratio and a scalable inverse Monte Carlo model was achieved for in vivo dysplastic cervical measurements (hemoglobin concentrations have been shown to be diagnostic for the detection of cervical pre-cancer by our group). These results indicate that use of such a simple ratiometric method has the potential to be used in clinical applications where tissue hemoglobin concentrations need to be rapidly quantified in vivo.

dc.description.version

Version of Record

dc.identifier

http://www.ncbi.nlm.nih.gov/pubmed/20940771

dc.identifier

205216

dc.identifier.eissn

1094-4087

dc.identifier.uri

https://hdl.handle.net/10161/4245

dc.language

eng

dc.language.iso

en_US

dc.publisher

The Optical Society

dc.relation.ispartof

Opt Express

dc.relation.journal

Optics Express

dc.subject

Computer Simulation

dc.subject

Female

dc.subject

Hemoglobins

dc.subject

Humans

dc.subject

Models, Statistical

dc.subject

Monte Carlo Method

dc.subject

Optics and Photonics

dc.subject

Phantoms, Imaging

dc.subject

Precancerous Conditions

dc.subject

Regression Analysis

dc.subject

Reproducibility of Results

dc.subject

Scattering, Radiation

dc.subject

Ultraviolet Rays

dc.subject

Uterine Cervical Neoplasms

dc.title

Rapid ratiometric determination of hemoglobin concentration using UV-VIS diffuse reflectance at isosbestic wavelengths.

dc.title.alternative
dc.type

Journal article

duke.date.pubdate

2010-8-30

duke.description.issue

18

duke.description.volume

18

pubs.author-url

http://www.ncbi.nlm.nih.gov/pubmed/20940771

pubs.begin-page

18779

pubs.end-page

18792

pubs.issue

18

pubs.organisational-group

Basic Science Departments

pubs.organisational-group

Biomedical Engineering

pubs.organisational-group

Duke

pubs.organisational-group

Duke Cancer Institute

pubs.organisational-group

Duke Science & Society

pubs.organisational-group

Global Health Institute

pubs.organisational-group

Initiatives

pubs.organisational-group

Institutes and Centers

pubs.organisational-group

Institutes and Provost's Academic Units

pubs.organisational-group

Pharmacology & Cancer Biology

pubs.organisational-group

Pratt School of Engineering

pubs.organisational-group

School of Medicine

pubs.organisational-group

University Institutes and Centers

pubs.publication-status

Published

pubs.volume

18

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
282107900030.pdf
Size:
1.23 MB
Format:
Adobe Portable Document Format