Using statistical process control charts to measure changes from a nurse-driven protocol to remove urinary catheters.

dc.contributor.author

Reynolds, Staci S

dc.contributor.author

Lozano, Halie

dc.contributor.author

Fleurant, Monique

dc.contributor.author

Bhandari, Kalpana

dc.date.accessioned

2023-03-30T18:25:36Z

dc.date.available

2023-03-30T18:25:36Z

dc.date.issued

2022-12

dc.date.updated

2023-03-30T18:25:36Z

dc.description.abstract

Background

Implementing a nurse-driven protocol (NDP) to remove indwelling urinary catheters is a strategy to reduce catheter-associated urinary tract infections (CAUTI). The purpose of this project was to implement a comprehensive NDP to reduce indwelling urinary catheter utilization and CAUTI rates at a large academic health system.

Methods

Statistical process control charts, a quality improvement method, was used to identify special cause variation. A formal protocol was developed to provide guidance for nurses to remove indwelling urinary catheters when no longer indicated. Changes were also made within the electronic health record.

Results

Signals of improvement were not noted on the Statistical process control charts for urinary catheter utilization or CAUTI rates. The frequency with which the NDP was documented (process measure) was assessed, showing it is used approximately 600 times each month. Of those catheters removed by the NDP, an average of 6% were reinserted within 48 hours (balancing measure).

Discussion

Our findings differed from other literature as we did not see a reduction in urinary catheter utilization after implementing a NDP. However, our project adds to the literature as we also evaluated process and balancing measures.

Conclusions

A NDP for urinary catheter removal provides nurses with the autonomy to remove catheters when no longer indicated; however, other interventions should be added to a comprehensive CAUTI-prevention program.
dc.identifier

S0196-6553(22)00143-2

dc.identifier.issn

0196-6553

dc.identifier.issn

1527-3296

dc.identifier.uri

https://hdl.handle.net/10161/26914

dc.language

eng

dc.publisher

Elsevier BV

dc.relation.ispartof

American journal of infection control

dc.relation.isversionof

10.1016/j.ajic.2022.03.005

dc.subject

Humans

dc.subject

Cross Infection

dc.subject

Urinary Tract Infections

dc.subject

Urinary Catheterization

dc.subject

Device Removal

dc.subject

Catheters, Indwelling

dc.subject

Catheter-Related Infections

dc.subject

Urinary Catheters

dc.title

Using statistical process control charts to measure changes from a nurse-driven protocol to remove urinary catheters.

dc.type

Journal article

duke.contributor.orcid

Reynolds, Staci S|0000-0002-0366-1328

pubs.begin-page

1355

pubs.end-page

1359

pubs.issue

12

pubs.organisational-group

Duke

pubs.organisational-group

School of Nursing

pubs.publication-status

Published

pubs.volume

50

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Reynolds et al. 2022_RN Driven Foley Removal.pdf
Size:
1003.63 KB
Format:
Adobe Portable Document Format