The development of a risk score for unplanned removal of peripherally inserted central catheter in newborns.

dc.contributor.author

Costa, Priscila

dc.contributor.author

Kimura, Amélia Fumiko

dc.contributor.author

Brandon, Debra Huffman

dc.contributor.author

Paiva, Eny Dorea

dc.contributor.author

de Camargo, Patricia Ponce

dc.coverage.spatial

Brazil

dc.date.accessioned

2015-12-17T21:33:09Z

dc.date.issued

2015-05

dc.description.abstract

OBJECTIVE: to develop a risk score for unplanned removal of peripherally inserted central catheter in newborns. METHOD: prospective cohort study conducted in a neonatal intensive care unit with newborn babies who underwent 524 catheter insertions. The clinical characteristics of the newborn, catheter insertion and intravenous therapy were tested as risk factors for the unplanned removal of catheters using bivariate analysis. The risk score was developed using logistic regression. Accuracy was internally validated based on the area under the Receiver Operating Characteristic curve. RESULTS: the risk score was made up of the following risk factors: transient metabolic disorders; previous insertion of catheter; use of a polyurethane double-lumen catheter; infusion of multiple intravenous solutions through a single-lumen catheter; and tip in a noncentral position. Newborns were classified into three categories of risk of unplanned removal: low (0 to 3 points), moderate (4 to 8 points), and high (≥ 9 points). Accuracy was 0.76. CONCLUSION: the adoption of evidence-based preventative strategies based on the classification and risk factors faced by the newborn is recommended to minimize the occurrence of unplanned removals.

dc.identifier

https://www.ncbi.nlm.nih.gov/pubmed/26155011

dc.identifier

S0104-11692015005012578

dc.identifier.eissn

1518-8345

dc.identifier.uri

https://hdl.handle.net/10161/11195

dc.language

eng por spa

dc.publisher

FapUNIFESP (SciELO)

dc.relation.ispartof

Rev Lat Am Enfermagem

dc.relation.isversionof

10.1590/0104-1169.0491.2578

dc.subject

Catheterization, Peripheral

dc.subject

Catheters, Indwelling

dc.subject

Device Removal

dc.subject

Female

dc.subject

Humans

dc.subject

Infant, Newborn

dc.subject

Male

dc.subject

Neonatal Nursing

dc.subject

Prospective Studies

dc.subject

Risk Assessment

dc.subject

Risk Factors

dc.title

The development of a risk score for unplanned removal of peripherally inserted central catheter in newborns.

dc.type

Journal article

pubs.author-url

https://www.ncbi.nlm.nih.gov/pubmed/26155011

pubs.begin-page

475

pubs.end-page

482

pubs.issue

3

pubs.organisational-group

Clinical Science Departments

pubs.organisational-group

Duke

pubs.organisational-group

Pediatrics

pubs.organisational-group

School of Medicine

pubs.organisational-group

School of Nursing

pubs.publication-status

Published

pubs.volume

23

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
The development of a risk score for unplanned removal of peripherally inserted central catheter in newborns.pdf
Size:
370.85 KB
Format:
Adobe Portable Document Format