Efficient Fetal-Maternal ECG Signal Separation from Two Channel Maternal Abdominal ECG via Diffusion-Based Channel Selection.

dc.contributor.author

Li, Ruilin

dc.contributor.author

Frasch, Martin G

dc.contributor.author

Wu, Hau-Tieng

dc.coverage.spatial

Switzerland

dc.date.accessioned

2017-12-17T22:57:34Z

dc.date.available

2017-12-17T22:57:34Z

dc.date.issued

2017

dc.description.abstract

There is a need for affordable, widely deployable maternal-fetal ECG monitors to improve maternal and fetal health during pregnancy and delivery. Based on the diffusion-based channel selection, here we present the mathematical formalism and clinical validation of an algorithm capable of accurate separation of maternal and fetal ECG from a two channel signal acquired over maternal abdomen. The proposed algorithm is the first algorithm, to the best of the authors' knowledge, focusing on the fetal ECG analysis based on two channel maternal abdominal ECG signal, and we apply it to two publicly available databases, the PhysioNet non-invasive fECG database (adfecgdb) and the 2013 PhysioNet/Computing in Cardiology Challenge (CinC2013), to validate the algorithm. The state-of-the-art results are achieved when compared with other available algorithms. Particularly, the F1 score for the R peak detection achieves 99.3% for the adfecgdb and 87.93% for the CinC2013, and the mean absolute error for the estimated R peak locations is 4.53 ms for the adfecgdb and 6.21 ms for the CinC2013. The method has the potential to be applied to other fetal cardiogenic signals, including cardiac doppler signals.

dc.identifier

https://www.ncbi.nlm.nih.gov/pubmed/28559848

dc.identifier.issn

1664-042X

dc.identifier.uri

https://hdl.handle.net/10161/15904

dc.language

eng

dc.publisher

Frontiers Media SA

dc.relation.ispartof

Front Physiol

dc.relation.isversionof

10.3389/fphys.2017.00277

dc.subject

de-shape short time Fourier transform

dc.subject

diffusion maps

dc.subject

fetal electrocardiogram

dc.subject

maternal abdominal electrocardiogram

dc.subject

nonlocal median

dc.title

Efficient Fetal-Maternal ECG Signal Separation from Two Channel Maternal Abdominal ECG via Diffusion-Based Channel Selection.

dc.type

Journal article

duke.contributor.orcid

Wu, Hau-Tieng|0000-0002-0253-3156

pubs.author-url

https://www.ncbi.nlm.nih.gov/pubmed/28559848

pubs.begin-page

277

pubs.organisational-group

Duke

pubs.organisational-group

Mathematics

pubs.organisational-group

Statistical Science

pubs.organisational-group

Temp group - logins allowed

pubs.organisational-group

Trinity College of Arts & Sciences

pubs.publication-status

Published online

pubs.volume

8

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Efficient Fetal-Maternal ECG Signal Separation from Two Channel Maternal Abdominal ECG via Diffusion-Based Channel Selection.pdf
Size:
1.56 MB
Format:
Adobe Portable Document Format
Description:
Published version