In vivo visualization of abdominal malignancies with acoustic radiation force elastography.
| dc.contributor.author | Fahey, BJ | |
| dc.contributor.author | Nelson, RC | |
| dc.contributor.author | Bradway, DP | |
| dc.contributor.author | Hsu, SJ | |
| dc.contributor.author | Dumont, DM | |
| dc.contributor.author | Trahey, GE | |
| dc.coverage.spatial | England | |
| dc.date.accessioned | 2015-08-12T17:01:16Z | |
| dc.date.issued | 2008-01-07 | |
| dc.description.abstract | The utility of acoustic radiation force impulse (ARFI) imaging for real-time visualization of abdominal malignancies was investigated. Nine patients presenting with suspicious masses in the liver (n = 7) or kidney (n = 2) underwent combined sonography/ARFI imaging. Images were acquired of a total of 12 tumors in the nine patients. In all cases, boundary definition in ARFI images was improved or equivalent to boundary definition in B-mode images. Displacement contrast in ARFI images was superior to echo contrast in B-mode images for each tumor. The mean contrast for suspected hepatocellular carcinomas (HCCs) in B-mode images was 2.9 dB (range: 1.5-4.2) versus 7.5 dB (range: 3.1-11.9) in ARFI images, with all HCCs appearing more compliant than regional cirrhotic liver parenchyma. The mean contrast for metastases in B-mode images was 3.1 dB (range: 1.2-5.2) versus 9.3 dB (range: 5.7-13.9) in ARFI images, with all masses appearing less compliant than regional non-cirrhotic liver parenchyma. ARFI image contrast (10.4 dB) was superior to B-mode contrast (0.9 dB) for a renal mass. To our knowledge, we present the first in vivo images of abdominal malignancies in humans acquired with the ARFI method or any other technique of imaging tissue elasticity. | |
| dc.identifier | ||
| dc.identifier | S0031-9155(08)56898-9 | |
| dc.identifier.issn | 0031-9155 | |
| dc.identifier.uri | ||
| dc.language | eng | |
| dc.publisher | IOP Publishing | |
| dc.relation.ispartof | Phys Med Biol | |
| dc.relation.isversionof | 10.1088/0031-9155/53/1/020 | |
| dc.subject | Abdominal Neoplasms | |
| dc.subject | Acoustics | |
| dc.subject | Aged | |
| dc.subject | Aged, 80 and over | |
| dc.subject | Biophysical Phenomena | |
| dc.subject | Biophysics | |
| dc.subject | Carcinoma, Hepatocellular | |
| dc.subject | Elasticity Imaging Techniques | |
| dc.subject | Female | |
| dc.subject | Humans | |
| dc.subject | Kidney Neoplasms | |
| dc.subject | Liver Neoplasms | |
| dc.subject | Male | |
| dc.subject | Middle Aged | |
| dc.subject | Tomography, X-Ray Computed | |
| dc.title | In vivo visualization of abdominal malignancies with acoustic radiation force elastography. | |
| dc.type | Journal article | |
| duke.contributor.orcid | Bradway, DP|0000-0002-6613-2415 | |
| pubs.author-url | ||
| pubs.begin-page | 279 | |
| pubs.end-page | 293 | |
| pubs.issue | 1 | |
| pubs.organisational-group | Biomedical Engineering | |
| pubs.organisational-group | Clinical Science Departments | |
| pubs.organisational-group | Duke | |
| pubs.organisational-group | Duke Cancer Institute | |
| pubs.organisational-group | Institutes and Centers | |
| pubs.organisational-group | Mechanical Engineering and Materials Science | |
| pubs.organisational-group | Pratt School of Engineering | |
| pubs.organisational-group | Radiology | |
| pubs.organisational-group | Radiology, Abdominal Imaging | |
| pubs.organisational-group | School of Medicine | |
| pubs.organisational-group | Staff | |
| pubs.publication-status | Published | |
| pubs.volume | 53 |
Files
Original bundle
- Name:
- nihms-39061.pdf
- Size:
- 1.98 MB
- Format:
- Adobe Portable Document Format
- Description:
- Published version