Structured Illumination Microscopy and a Quantitative Image Analysis for the Detection of Positive Margins in a Pre-Clinical Genetically Engineered Mouse Model of Sarcoma.

dc.contributor.author

Fu, H

dc.contributor.author

Mueller, J

dc.contributor.author

Whitley, M

dc.contributor.author

Cardona, D

dc.contributor.author

Willett, R

dc.contributor.author

Kirsch, D

dc.contributor.author

Brown, Q

dc.contributor.author

Ramanujam, N

dc.date.accessioned

2015-11-16T19:24:51Z

dc.date.issued

2016

dc.description.abstract

Intraoperative assessment of surgical margins is critical to ensuring residual tumor does not remain in a patient. Previously, we developed a fluorescence structured illumination microscope (SIM) system with a single-shot field of view (FOV) of 2.1 × 1.6 mm (3.4 mm2) and sub-cellular resolution (4.4 μm). The goal of this study was to test the utility of this technology for the detection of residual disease in a genetically engineered mouse model of sarcoma. Primary soft tissue sarcomas were generated in the hindlimb and after the tumor was surgically removed, the relevant margin was stained with acridine orange (AO), a vital stain that brightly stains cell nuclei and fibrous tissues. The tissues were imaged with the SIM system with the primary goal of visualizing fluorescent features from tumor nuclei. Given the heterogeneity of the background tissue (presence of adipose tissue and muscle), an algorithm known as maximally stable extremal regions (MSER) was optimized and applied to the images to specifically segment nuclear features. A logistic regression model was used to classify a tissue site as positive or negative by calculating area fraction and shape of the segmented features that were present and the resulting receiver operator curve (ROC) was generated by varying the probability threshold. Based on the ROC curves, the model was able to classify tumor and normal tissue with 77% sensitivity and 81% specificity (Youden's index). For an unbiased measure of the model performance, it was applied to a separate validation dataset that resulted in 73% sensitivity and 80% specificity. When this approach was applied to representative whole margins, for a tumor probability threshold of 50%, only 1.2% of all regions from the negative margin exceeded this threshold, while over 14.8% of all regions from the positive margin exceeded this threshold.

dc.identifier

http://www.ncbi.nlm.nih.gov/pubmed/26799613

dc.identifier.uri

https://hdl.handle.net/10161/10892

dc.relation.isversionof

10.1371/journal.pone.0147006

dc.subject

Animals

dc.subject

Disease Models, Animal

dc.subject

Genetic Engineering

dc.subject

Mice

dc.subject

Microscopy, Fluorescence

dc.subject

Sarcoma

dc.title

Structured Illumination Microscopy and a Quantitative Image Analysis for the Detection of Positive Margins in a Pre-Clinical Genetically Engineered Mouse Model of Sarcoma.

dc.type

Other article

duke.contributor.orcid

Whitley, M|0000-0002-8163-6881

duke.contributor.orcid

Cardona, D|0000-0002-6877-2280

duke.contributor.orcid

Ramanujam, N|0000-0001-7319-8415

pubs.author-url

http://www.ncbi.nlm.nih.gov/pubmed/26799613

pubs.organisational-group

Basic Science Departments

pubs.organisational-group

Clinical Science Departments

pubs.organisational-group

Duke

pubs.organisational-group

Duke Cancer Institute

pubs.organisational-group

Institutes and Centers

pubs.organisational-group

Pathology

pubs.organisational-group

Pharmacology & Cancer Biology

pubs.organisational-group

Radiation Oncology

pubs.organisational-group

School of Medicine

pubs.organisational-group

Staff

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
ExVivo 30 Images.zip
Size:
2.25 MB
Format:
Unknown data format
Description:
Supporting information