Browsing by Author "Stroh, D Alex"
Now showing 1 - 2 of 2
Results Per Page
Sort Options
Item Open Access Rare Complications of Cervical Spine Surgery: Horner's Syndrome.(Global spine journal, 2017-04) Traynelis, Vincent C; Malone, Hani R; Smith, Zachary A; Hsu, Wellington K; Kanter, Adam S; Qureshi, Sheeraz A; Cho, Samuel K; Baird, Evan O; Isaacs, Robert E; Rahman, Ra'Kerry K; Polevaya, Galina; Smith, Justin S; Shaffrey, Christopher; Tortolani, P Justin; Stroh, D Alex; Arnold, Paul M; Fehlings, Michael G; Mroz, Thomas E; Riew, K DanielA multicenter retrospective case series.Horner's syndrome is a known complication of anterior cervical spinal surgery, but it is rarely encountered in clinical practice. To better understand the incidence, risks, and neurologic outcomes associated with Horner's syndrome, a multicenter study was performed to review a large collective experience with this rare complication.We conducted a retrospective multicenter case series study involving 21 high-volume surgical centers from the AOSpine North America Clinical Research Network. Medical records for 17 625 patients who received subaxial cervical spine surgery from 2005 to 2011 were reviewed to identify occurrence of 21 predefined treatment complications. Descriptive statistics were provided for baseline patient characteristics. Paired t test was used to analyze changes in clinical outcomes at follow-up compared to preoperative status.In total, 8887 patients who underwent anterior cervical spine surgery at the participating institutions were screened. Postoperative Horner's syndrome was identified in 5 (0.06%) patients. All patients experienced the complication following anterior cervical discectomy and fusion. The sympathetic trunk appeared to be more vulnerable when operating on midcervical levels (C5, C6), and most patients experienced at least a partial recovery without further treatment.This collective experience suggests that Horner's syndrome is an exceedingly rare complication following anterior cervical spine surgery. Injury to the sympathetic trunk may be limited by maintaining a midline surgical trajectory when possible, and performing careful dissection and retraction of the longus colli muscle when lateral exposure is necessary, especially at caudal cervical levels.Item Open Access Risk of dislocation using large- vs. small-diameter femoral heads in total hip arthroplasty.(BMC Res Notes, 2012-10-05) Plate, Johannes F; Seyler, Thorsten M; Stroh, D Alex; Issa, Kimona; Akbar, Michael; Mont, Michael ABACKGROUND: Dislocation remains a difficult problem in total hip arthroplasty. Large-diameter femoral heads may lower the incidence of dislocation by enhancing the jump distance and decreasing impingement, but their performance against small-diameter heads has not been assessed. This study compared the mid-term radiographic and functional outcomes of two matched cohorts of patients undergoing total hip arthroplasty who had a high pre-operative risk for dislocation and who received either small-diameter (26- or 28-millimeters) or large-diameter (≥36-millimeters) femoral heads. METHODS: All patients who received large-diameter heads (≥36-millimeter) between 2002 and 2005, and who had pre-operative risk factors for dislocation, were identified in the institution's joint registry. Forty-one patients (52 hips) who received large-diameter heads were identified, and these patients were matched to 48 patients (52 hips) in the registry who received small-diameter femoral heads. RESULTS: At mean final follow-up of 62 months (range, 49 to 101 months), both groups achieved excellent functional outcomes as measured by Harris Hip scores, with slightly better final scores in the large-diameter group (90 vs. 83 points). No patient showed any radiographic signs of loosening. No patient dislocated in the large-diameter femoral head group; the smaller-diameter group had a greater rate of dislocation (3.8%, 2 out of 52). CONCLUSIONS: Large-diameter femoral head articulations may reduce dislocation rates in patients who have a high pre-operative risk for dislocation while providing the same functional improvements and safety as small-diameter bearings.