Evaluation of Eddy-current distortion and EPI distortion corrections in MR diffusion imaging using log-demons DIR method

Thumbnail
View / Download
1.4 Mb
Date
2020
Author
Arsenault, Theodore H
Advisors
Chang, Zheng
Yin, Fang Fang
Repository Usage Stats
169
views
84
downloads
Abstract

Purpose: To investigate the feasibility of the Log-Demons deformable image registration (DIR) method to correct eddy current and Echo Planar Imaging (EPI) distortions while preserving diffusion tensor information.

Methods: A phantom MR scan was conducted using a diffusion phantom scan (Diffusion Phantom Model 128, High Precision Devices, Inc) on a clinical 3T scanner. The scan includes a standard T1-weighted scan and a 20‐direction diffusion tensor imaging (DTI) scan, which consists of one data set with b=0s/mm2 and twenty diffusion-weighted data sets with b=1,000s/mm2. A Log-Demons DIR algorithm was applied to the DTI images for eddy current and EPI distortion correction based on the b=0s/mm2 and T1 weighted data sets and compared the eddy current and EPI distortion corrections along the phase encoding direction by affine and demons DIR algorithms. The Log-Demons framework is optimized based on both similarity and regularization. The registered images were analyzed using Cross-correlation (CC) and mutual information (MI) to assess the performances of distortion corrections by the DIR methods. Quantitative deviations from the original data after correction were also evaluated using the mean, and root mean square error (RMSE) for thirteen regions of interest in the Apparent Diffusion Coefficient (ADC) and Fractional Anisotropy (FA) maps.

The Log-Demons DIR algorithm was then applied to the MASSIVE dataset, which provides diffusion-weighted volumes divided into four sets with both positive (+) and negative(-) diffusion gradient directions and both AP and PA phase encoding directions. The registered images were analyzed using the mutual information (MI) and the absolute mean difference of two images with opposing gradient directions to assess the performances of distortion corrections by the DIR methods. Images with opposing gradient directions were compared when comparing eddy current distortions and images with opposing phase encoding directions were compared for EPI distortions.

Results: In the phantom study, the MI and CC were improved by 2.15%,0.89%, and 39.39% compared to no correction, and affine, and demons algorithm respectively when correction for eddy current distortions. MI and CC were improved by 8.89%, 9.33%, and 9.20% compared to no correction, and affine, and demons algorithm respectively when correction for EPI distortions. Analysis of the tensor metrics using percent difference and the RMS of the ADC and FA found that the Log-Demons algorithm outperforms the other algorithms in terms of preserving diffusion information.

In the MASSIVE study, the Log-demons DIR method outperformed the demons algorithm in terms of MI but underperformed compared to the affine registration for both eddy current and EPI distortions corrections. The absolute mean difference was decreased by 2.94%, 0.44%, and 1.53% compared to no correction, and affine, and demons algorithm respectively when correcting for eddy current distortions, and decreased by 0.39%, 8.03%, and 13.19% compared to no correction, and affine, and demons algorithm respectively when correcting for EPI distortions.

Conclusion: This work indicates that the Log-Demons DIR algorithm is feasible to reduce eddy current and EPI distortions while preserving quantitative diffusion information. Although demonstrated with a DTI phantom study and brain study, this method could be extended for areas in which diffusion-weighted imaging is beneficial.

Description
Master's thesis
Type
Master's thesis
Department
Medical Physics
Subject
Medical imaging
Physics
Diffusion Wieghted Imaging
Distortion
Eddy Current
Medical
MRI
Permalink
https://hdl.handle.net/10161/20797
Citation
Arsenault, Theodore H (2020). Evaluation of Eddy-current distortion and EPI distortion corrections in MR diffusion imaging using log-demons DIR method. Master's thesis, Duke University. Retrieved from https://hdl.handle.net/10161/20797.
Collections
  • Masters Theses
More Info
Show full item record
Creative Commons License
This work is licensed under a Creative Commons Attribution-Noncommercial-No Derivative Works 3.0 United States License.

Rights for Collection: Masters Theses


Works are deposited here by their authors, and represent their research and opinions, not that of Duke University. Some materials and descriptions may include offensive content. More info

Make Your Work Available Here

How to Deposit

Browse

All of DukeSpaceCommunities & CollectionsAuthorsTitlesTypesBy Issue DateDepartmentsAffiliations of Duke Author(s)SubjectsBy Submit DateThis CollectionAuthorsTitlesTypesBy Issue DateDepartmentsAffiliations of Duke Author(s)SubjectsBy Submit Date

My Account

LoginRegister

Statistics

View Usage Statistics
Duke University Libraries

Contact Us

411 Chapel Drive
Durham, NC 27708
(919) 660-5870
Perkins Library Service Desk

Digital Repositories at Duke

  • Report a problem with the repositories
  • About digital repositories at Duke
  • Accessibility Policy
  • Deaccession and DMCA Takedown Policy

TwitterFacebookYouTubeFlickrInstagramBlogs

Sign Up for Our Newsletter
  • Re-use & Attribution / Privacy
  • Harmful Language Statement
  • Support the Libraries
Duke University